1、BSI Standards PublicationBS EN 2665-001:2013Aerospace series Circuitbreakers, three-pole,temperature compensated,rated current 20 A to 50 APart 001: Technical specificationBS EN 2665-001:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 2665-001:2013.It super
2、sedes BS EN 2665-001:1999 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can beobtained on request to its secretary.This publication doe
3、s not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 83443 1ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obli
4、gations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 December 2013.Amendments issued since publicationDate Text affectedBS EN 2665-001:2013EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 2665-001 December 2013 ICS 49.060 English Ver
5、sion Aerospace series - Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A - Part 001: Technical specification Srie arospatiale - Disjoncteurs tripolaires compenss en temprature, intensits nominales 20 A 50 A - Partie 001 : Spcification technique Luft- und Raumfahrt -
6、Schutzschalter, dreipolig, temperaturkompensiert, Nennstrme von 20 A bis 50 A - Teil 001: Technische Lieferbedingungen This European Standard was approved by CEN on 28 September 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
7、this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three officia
8、l versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Au
9、stria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swe
10、den, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for C
11、EN national Members. Ref. No. EN 2665-001:2013 EBS EN 2665-001:2013EN 2665-001:2013 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Description .4 5 Design .5 6 Characteristic .6 7 Tests 7 8 Qualification tests . 15 9 Quality assurance . 18 10 Marking 1
12、8 11 Delivery conditions . 18 12 Packaging 19 13 Storage . 19 BS EN 2665-001:2013EN 2665-001:2013 (E) 3 Foreword This document (EN 2665-001:2013) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in acc
13、ordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication
14、of an identical text or by endorsement, at the latest by June 2014, and conflicting national standards shall be withdrawn at the latest by June 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be
15、held responsible for identifying any or all such patent rights. This document supersedes EN 2665-001:1999. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cro
16、atia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
17、the United Kingdom. BS EN 2665-001:2013EN 2665-001:2013 (E) 4 1 Scope This European Standard specifies the three-pole temperature compensated circuit breakers without signal contacts, rated from 20 A to 50 A and used in aircraft on-board circuits. It describes specific environmental, electrical and
18、mechanical characteristics and the stringency of tests to be applied according to test methods of EN 3841-100. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282. 2 Normative references The following documents, in whole or in part, are normati
19、vely referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies EN 2083, Aerospace series Copper or copper alloy conductors for e
20、lectrical cables Product standard EN 2282, Aerospace series Characteristics of aircraft electrical supplies EN 2665-004, Aerospace series Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A Part 004: UNC thread terminals Product standard EN 2825, Aerospace series Burnin
21、g behaviour of non metallic materials under the influence of radiating heat and flames Determination of smoke density EN 2826, Aerospace series Burning behaviour of non metallic materials under the influence of radiating heat and flames Determination of gas components in the smoke EN 3841-100 (all p
22、arts), Aerospace series Circuit breakers Test Methods Part 100: GeneralEN 3844-1, Aerospace series Flammability of non metallic materials Part 1: Small burner test, vertical Determination of the vertical flame propagation EN 9133, Aerospace series Quality management systems Qualification procedure f
23、or aerospace standards TR 6083, Aerospace series Cut-outs for installation of electrical components 1)3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3841-100 apply. 4 Description These circuit breakers are operated by a “push-pull“ type single push b
24、utton (actuator) and with delayed action “trip-free“ tripping. Their function is assured up to the short-circuit current. 1) Published as ASD-STAN Technical Report at the date of publication of this standard. http:/www.asd-stan.org/ BS EN 2665-001:2013EN 2665-001:2013 (E) 5 5 Design 5.1 Materials 5.
25、1.1 Metallic materials All metallic parts shall be resistant to corrosion or finished against corrosion. When dissimilar materials are in close contact, an adequate protection against corrosion shall be used so that the electromotive force of the galvanic couple does not exceed 0,25 V. When bimetals
26、 are used, an eventual corrosion shall not affect the good operation of the circuit breaker. 5.1.2 Insulation materials The insulating parts shall be made of auto-extinguishing or non-flammable materials; they shall not emit damaging or explosive vapours, even in presence of fire or internal electri
27、c arc. They shall be insensitive to moulds and microorganisms action. Application of any material or protective coating, which might crack, break on flake shall be forbidden. Materials which are not specified or which are not specially described shall be as light as possible for the requested use. M
28、aterials shall be selected according to security criteria (toxicity, smoke density) as defined in contractual documents. 5.2 Design 5.2.1 Insulating box The insulating box shall integrate besides the mechanism, the connection and attachment unit. 5.2.2 Free release mechanism Design of circuit breake
29、r mechanism shall allow free release; i.e. the circuit breaker cuts out in case of overload, and remains cut out even if the actuator is kept by force in engaged position. A new engagement of circuit breaker is only possible after a first total release of the control actuator. The operation in these
30、 conditions shall not affect further performances of the circuit breaker. 5.2.3 Attachment All visible parts shall be black colored and non-reflective. 5.2.4 Electrical connection units They shall be able to receive the lugs. 5.2.5 Control actuator In engaged position, the visible part of the contro
31、l actuator shall be of the colour stated in the product standard. In disengaged (or opened) position, the control actuator shall show a white strip. The outer part of this actuator shall be isolated from all under voltage parts. BS EN 2665-001:2013EN 2665-001:2013 (E) 6 The control actuator shall no
32、t stay in a transition position, or give a false indication about the circuit breaker condition. It shall not be removable. When pushing it, power contacts of the circuit breaker engage. When pulling it, power contacts of the circuit breaker open. The circuit breaker rating is indicated in indelible
33、 white colour on the front part of the control actuator. The product standard gives the digits positioning. 5.2.6 Rating inviolability The circuit breaker shall be designed in such a way that the calibration unit cannot be reached without breaking a sealing. 5.2.7 Leakage lines The leakage lines and
34、 the minimal space to be foreseen between the under voltage parts and any other part of the circuit breaker made of non-insulating material, as well as between the under voltage parts of opposite polarity, shall be sufficient to avoid any default or arcing in all uses and climatic conditions. 5.2.8
35、Protection against non-release Electrical overload happening on a circuit breaker locked in its engaged position (sticked contacts or non-operating release mechanism), shall cause the opening of the circuit by circuit breaker destruction without any fire or important smoke release. 6 Characteristic
36、6.1 General characteristics See Table 1. Table 1 General characteristics Designation Requirements Assembly See product standard. Mass See product standard. Operational altitude See product standard. 3 input terminals on power supply side (identified by digit A1, B1, C1) See product standard. 3 outpu
37、t terminals on distribution side (identified by digit A2, B2, C2) Operational ambient temperatures limits From 55 C to 90 C Temperature compensation From 55 C to 90 C See product standard. Rating marking On control actuator (indelible white) BS EN 2665-001:2013EN 2665-001:2013 (E) 7 6.2 Ratings See
38、product standard. 6.3 Nominal voltage of operational circuits See product standard. 6.4 Dimensional characteristics See product standard. 6.5 Recommended panel mounting dimensions Panel cut-out : the panel cut-out is in accordance with the designation TR6083C202 (for EN 2665-004). Spacing : 60 mm ho
39、rizontal and 45 mm vertical from the centers of the mounting holes. Panel thickness : 1 mm to 3 mm. 7 Tests 7.1 Mechanical tests See Table 2. Table 2 Mechanical characteristics Tests Requirements Visual check EN 3841-201 Operational force Closing force (push) EN 3841-502 8 N to 80 N Opening force (p
40、ull) 5 N to 45 N Mechanical strength Actuator Travel EN 3841-501 For value, see product standard. Transverse load EN 3841-503 110 N Longitudinal load Push 110 N Pull 110 N Attachment nut Tightening torque EN 3841-504 5,5 N.m Rotation torque 3 N.m Main contact connection Screw tightening torque EN 38
41、41-505 2,5 N.m Tensile force as per F1(see Figure 1 in product standard). 110 N Pressure force as per F2(see Figure 1 in product standard). 55 N BS EN 2665-001:2013EN 2665-001:2013 (E) 8 7.2 Environmental tests See Table 3. Table 3 Environmental conditions (1 of 2) Tests Requirements Combined tests.
42、 Ambient temperature 70 C and vibrations (see notes). Sinusoidal (see Figure 1). Duration: circuit breaker in the “closed“ position; 0,9 nload Seven cycles/axis 1 octave/min; no load Two cycles/axis 1 octave/min. circuit breaker in the “opened“ position; two cycles/axis 1 octave/min. See EN 3841-506
43、. 5 Hz to 80 Hz Constant amplitude 2 a = 0,76 mm 80 Hz to 500 Hz Constant acceleration = 10 gn500 Hz to 2 000 Hz Constant acceleration = 5 gnRandom (see Figure 2). Duration: circuit breaker in the “closed“ position; 0,9 nload 15 min/axis; no load 15 min/axis. circuit breaker in the “opened“ position
44、; 15 min/axis. 10 Hz to 2 000 Hz Constant acceleration = 5,8 gnLow frequencies (see Figure 3). Applicability: see product standard. Duration: circuit breaker in the “closed“ position; 0,9 nload Two cycles/axis; no load Two cycles/axis. circuit breaker in the “opened“ position; two cycles/axis. 10 Hz
45、 to 27 Hz to 10 Hz Constant acceleration = 10 gn10 Hz to 5 Hz Constant acceleration = 3,5 gnCombined tests. Ambient temperature 85 C, cabin max. altitude 4 600 m and vibrations (see notes). Sinusoidal Applicability: see product standard. Duration: circuit breaker in the “closed“ position; 0,9 nload
46、Four cycles/axis 1 octave/min; no load Two cycles/axis 1 octave/min. circuit breaker in the “opened“ position; two cycles/axis 1 octave/min. See EN 3841-511. 5 Hz to 54 Hz Constant shift 2 a = 0,5 mm 54 Hz to 2 000 Hz Constant acceleration = 3 gnBS EN 2665-001:2013EN 2665-001:2013 (E) 9 Table 3 Envi
47、ronmental conditions (2 of 2) Tests Requirements Mechanical shocks (see notes) 50 gn 11 ms Half sine wave See EN 3841-507. Constant accelerations See product standard. Sand and dust See product standard. Corrosion (salt spray) See EN 3841-402, category S. Humidity See EN 3841-403, category A. Explos
48、ion-proofing See product standard. Contaminating liquids Cleaning and extinguishing products See EN 3841-405. Flammability (glow wire test) See EN 3841-406. Inflammability See test EN 3844-1, code B. Smoke density See test EN 2825, code A or code B. Toxicity See test EN 2826, code B. Overvoltage cau
49、sed by lightning only on main contacts See EN 3841-308. Requirement: no tripping NOTE 1 Vibration tests performed on circuit breakers in closed position without load and in opened position, are carried out in order to detect contact opening and closure. NOTE 2 For vibration and shock tests, the contact-opening or contact-closure shall be less than or equal to 10 s on the power and the signal contacts. NOTE