1、BRITISH STANDARDBS EN 2995-005:2006Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 1 A to 25 A Part 005: With polarized signal contact Product standardThe European Standard EN 2995-005:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g4
2、9g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 2995-005:2006This British St
3、andard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50011 4National forewordThis British Standard was published by BSI. It is the UK implementation of EN 2995-005:2006.The UK participation in its preparation was entrusted
4、by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to include all the nec
5、essary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled
6、Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 2995-005August 2006ICS 49.060English VersionAerospace series - Circuit breakers, single-pole, temperaturecompensated, rated current 1 A to 25 A - Part 005: Withpolarized signal contact - Product standardSrie arospatiale - Disjoncteurs un
7、ipolaires compenss entemprature, intensits nominales 1 A 25 A - Partie 005 :Avec contact de signalisation polaris - Norme de produitLuft- und Raumfahrt - Schutzschalter, einpolig,Temperaturkompensiert, Nennstrme von 1 A bis 25 A -Teil 005: Mit polarisiertem Signalkontakt - ProduktnormThis European S
8、tandard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning su
9、ch nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language an
10、d notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Neth
11、erlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in
12、 any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2995-005:2006: ELicensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Dimensions and mass.4 4 Characteristics.6 5 Desi
13、gnation 11 6 Rated current code 11 7 Delivery codes .11 8 Marking .12 9 Technical specification .12 EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI3 Foreword This European Standard (EN 2995-005:2006) has been prepared by the Aerospace and D
14、efence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its pr
15、esentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention is drawn to the po
16、ssibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries
17、 are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Swi
18、tzerland and the United Kingdom. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI4 1 Scope This standard specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 1 A to 25 A, used in ai
19、rcraft on-board circuits at a temperature between 55 C and 125 C and at a maximum altitude of Z = 22 000 m. These circuits breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-free“ tripping with a polarized signal contact which is open when main contact
20、s are closed, and inversely. They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edit
21、ion of the referenced document (including any amendments) applies. EN 2995-001, Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 1 A to 25 A Part 001: Technical specification. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part
22、016: Contacts, electrical, male, type A, crimp, class S Product standard. EN 3841-305, Aerospace series Circuit breakers Test methods Part 305: Short-circuit performance. EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware.1)TR 6083, Aerospace series Cut-outs for installati
23、on of electrical components.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B.3)MIL-S-19500, Semiconductor device, diode, silic
24、on, fast recovery.3)FED-STD-595B, Colors used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. 1)
25、Published as AECMA Prestandard at the date of publication of this standard. 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr
26、05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI5 Key 1 Push button released 9 2 Green colour according to FED-STD-595B No. 34090 Gauge 20 connection pins according to EN3155-016M2018 3 White 10 Indicative value 25 (see note) 4 Marking area, see Clause 8. 11 Marking, see Clause 6. 5 Push butto
27、n pressed 12 6 Attachment nut Positioning lug in accordance with the panel cut-out, as per TR6083C202 7 Lockwasher 13 Rated current marking (white on green) 8 1,0 to 3,0 max. 14 Terminals shape free F1 and F2: see EN 2995-001, Table 3. NOTE Tools noted in subclause 4.2.4 shall be applied without int
28、erfering with the terminal 2 connection. Even if circuit breakers are grouped. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI6 Figure 1 Configuration Dimensions Tolerances 3.2 Electrical diagram See Figure 2. Terminal No.: 1 and 2: Main co
29、ntacts 3 and 5: Signal contacts Figure 2 Electrical diagram 3.3 Mass 28 g max. (delivery code A including hardware). 3.4 Panel mounting See EN 2995-001. 4 Characteristics 4.1 Material, surface treatment See EN 2995-001. 4.2 Mechanical characteristics 4.2.1 Fasteners See EN 6113. 4.2.2 Recommended ti
30、ghtening torque of attaching nut for installation (4,75 0,25) Nm 4.2.3 Recommended tightening torque of connection hardware for installation (1,6 0,1) Nm 4.2.4 Recommended tools for contacts of auxiliary contact insertion and extraction plastic MIL-I-81969/14-11; metallic MIL-I-81969/1-02. 353521or3
31、521or35Push-button released Push-button pressedEN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI7 4.2.5 Resistance to vibrations 4.2.5.1 Combined test: ambient temperature at 70 C and vibrations Sinusoidal: 10 gn, see EN 2995-001. Random: 5,8
32、 gn, see EN 2995-001. Low frequencies: 10 gn, see EN 2995-001. 4.2.5.2 Combined test: ambient temperature at 85 C, altitude and vibrations Sinusoidal: 3 gn, see EN 2995-001. 4.2.6 Resistance to shocks 50 gn, see EN 2995-001. 4.2.7 Mechanical endurance See Table 6. 4.3 Environment characteristics 4.3
33、.1 Humidity See EN 2995-001. 4.3.2 Corrosion See EN 2995-001. 4.3.3 Contaminating liquids See EN 2995-001. 4.3.4 Overvoltage caused by lightning See EN 2995-001. 4.4 Electrical characteristics 4.4.1 Nominal voltages of main contacts See Table 1. Table 1 28 V d.c. 26 V a.c., 360 Hz to 800 Hz Nominal
34、voltages 115 V a.c., 360 Hz to 800 Hz EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI8 4.4.2 Diode of signal contact characteristics Max. current at 125 C: 0,5 A. Peak repetitive reversal voltage: 800 V min. Quality standard: JANTX accordin
35、g to MIL-S-19500. 4.4.3 Voltage drop at nand at low current See Table 2. Table 2 Ratings A 1 2 2,5 3 5 7,5 10 15 20 25 U max. at n V 1,10 0,75 0,70 0,55 0,35 0,30 0,30 0,25 0,25 0,20 U max. at = 100mA mV 110 40 30 18 8 4 3 2,5 2,5 2,5 Signal circuit: 28 V d.c.; I = 3 mA : U 1,0 V. NOTE When a signal
36、 contact has been operated with a power greater than 60 mW and/or with a voltage higher than 28 V d.c., it loses its low current quality. 4.4.4 Minimum and maximum tripping thresholds See Table 3. Table 3 Overload (in % of n) Minimum thresholds value 1 h Maximum thresholds value 1 h Ambient temperat
37、ures C Ratings On ground At 22 000 m On ground 23 5 115 105 140 55 5 115 105 160 70 5 105 100 140 125 5 All 100 80 140 4.4.5 Overload trip See Table 4. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI9 Table 4 Overload (in % of n) 200 500 1
38、000 Ambient temperatures C Ratings A Trip time s 1 to 3 2 to 13 5 to 15 4 to 18 23 5 20 to 25 6 to 20 55 5 40 125 5 All 1,5 0,15 to 2,50 0,035 to 0,600 4.4.6 Short-circuit values See Table 5. Table 5 Nominal voltage 28 V d.c. 115 V a.c., 360 Hz to 800 Hz 0,8 cos 1 Prospective currents 4 000 A L/R 1
39、ms 1 800 A r.m.s. 1 500 A r.m.s. 1 100 A r.m.s. Test altitudes On the ground and at maximum altitude 22 000 m (4 000 Pa) On the ground and at cabin maximum altitude (4 600 m, 57 400 Pa) At maximum altitude (22 000 m,4 000 Pa) Number of operations CO a+ 2 OCO bSee note. 1 CO a+ 2 OCO b1 CO a+ 2 OCO b
40、aBreak operation (for definition see EN 3841-305). bMake operation (for definition see EN 3841-305). NOTE For the test at 1 800 A, an opening of the circuit by a destruction of the circuit breaker, (without bursting, flaming or thick smokes) is allowed even if this destruction happens during the fir
41、st CO. If the product passes 1 CO + 2 OCO at 1 800 A/115 V a.c., tests at 1 100 A and 1 500 A will not be necessary. 4.4.7 No-load and load endurance See Table 6. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI10 Table 6 Number of operation
42、s to be provided No-load Load 5 000 2 500 2 500 2 500 2 500 Main contacts ApplicableResistive Low current 100 mA, 28 V d.c.(rating 3 A) Inductive 0,6 cos 0,7n, 115 V a.c. - 360 Hz to 800 Hz Resistive n, 28 V d.c. Inductive L/R = 5 ms n, 28 V d.c. All ratings Signal contacts ApplicableResistive 0,5 A
43、, 28 V d.c. Resistive 3 mA, 8 V d.c Resistive 3 mA, 5 V d.c Lamp 0,2 A, 28 V d.c.NOTE 1 One operation corresponds to one closing and one opening. NOTE 2 Tolerances 5 % on current, voltage and frequency values. 4.4.8 Dielectric rigidity See Table 7. Table 7 Closed position Z = 0 m Z = 22 000 m 1 and
44、2 with attachment 1 and 2 with 3 1 and 2 with 5 1 500 V 400 V 3 with 5 3 and 5 with attachment 500 V 150 V Open position Z = 0 m Z = 22 000 m 1 with 2 1 and 2 with attachment 3 and 5 with 1 3 and 5 with 2 1 500 V 400 V 3 and 5 with attachment 500 V 150 V 4.4.9 Insulation resistance According to EN 2
45、995-001, Table 5. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI11 5 Designation EXAMPLE Description block CIRCUIT BREAKER Identity block EN2995-005A20AA Number of EN standard Design code, A: green button Rated current code (see Table 8) D
46、elivery code A (see Table 9) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. 6 Rated current code See Table 8. Table 8 Rating current n (A) 1 2 2,5 3 5 7,5 10 15 20 25 Marking on actuator 1 2 2 3 5 7 10 15 20 25 Rated current code 01A 02A 2A5 0
47、3A 05A 7A5 10A 15A 20A 25A 7 Delivery codes See Table 9. Table 9 Connection and attachment hardware kits EN 6113 Delivery conditions Delivery code Kit part-No. aIncluded parts Pieces per part Fitted Supplied separately Connecting screw 2 Connecting lock washer 2 Attachment nut 1 A EN6113A1 Attachmen
48、t lock washer 1 X Attachment nut 1 B EN6113B1 Attachment lock washer 1 X aSpare parts could be ordered separately, for information see EN 6113. EN 2995-005:2006Licensed Copy: Wang Bin, na, Thu Apr 05 02:46:34 GMT+00:00 2007, Uncontrolled Copy, (c) BSI12 8 Marking As defined on the drawing and unless
49、 otherwise specified by contract, marking shall include: the designation defined in Clause 5 (without delivery hardware code), on the packaging; the manufacture date (year, week); the manufacturers name or trademark; the electrical diagram and the terminal identification; the manufacturers part number (corresponding to the part number which includes connection and attachment hardware supplied separately in a bag). NOTE The marking could be on b