1、BSI Standards PublicationBS EN 3660-063:2015Aerospace series Cableoutlet accessories for circularand rectangular electrical andoptical connectorsPart 063: Cable outlet, style K, straight, forheat shrinkable boot, shielded, sealed, self-locking for EN 3645 Product standardBS EN 3660-063:2015 BRITISH
2、STANDARDNational forewordThis British Standard is the UK implementation of EN 3660-063:2015.It supersedes BS EN 3660-063:2009 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organiz
3、ations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN
4、 978 0 580 89594 4ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 November 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t
5、 e dBS EN 3660-063:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 3660-063 November 2015 ICS 49.060 Supersedes EN 3660-063:2009English Version Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 063: Cable outlet, style K, strai
6、ght, for heat shrinkable boot, shielded, sealed, self-locking for EN 3645 - Product standard Srie arospatiale - Accessoires arrire pour connecteurs circulaires et rectangulaires lectriques et optiques - Partie 063 : Raccord type K, droit, blind, tanche, pour manchon thermortractable, auto-frein pour
7、 EN 3645 - Norme de produit Luft- und Raumfahrt - Endgehuse fr elektrische und optische Rund- und Rechtecksteckverbinder - Teil 063: Endgehuse, Bauform K, gerade, fr wrmeschrumpfende Bauteile, Schirmanschluss, abgedichtet, selbstsichernd fr EN 3645 - Produktnorm This European Standard was approved b
8、y CEN on 8 June 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standard
9、s may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notif
10、ied to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Ice
11、land, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Manag
12、ement Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3660-063:2015 EBS EN 3660-063:2015EN 3660-063:2015 (E) 2 Contents Page European foreword 3 1 Scope . 4 2 Normative references 4 3
13、Terms and definitions . 5 4 Characteristics . 5 5 Tests 11 6 Designation . 18 7 Marking 18 8 Technical specification . 18 BS EN 3660-063:2015EN 3660-063:2015 (E) 3 European foreword This document (EN 3660-063:2015) has been prepared by the Aerospace and Defence Industries Association of Europe - Sta
14、ndardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Sta
15、ndard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2016, and conflicting national standards shall be withdrawn at the latest by May 2016. Attention is drawn to the possibility that some of the elements of this do
16、cument may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 3660-063:2009. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries ar
17、e bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Po
18、rtugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 3660-063:2015EN 3660-063:2015 (E) 4 1 Scope This European Standard defines a range of cable outlets, style K, straight, shielded, sealed, self-locking (anti-rotational), heat shrinkable boot, and /
19、or metallic bands for use under the following conditions: Associated electrical connector(s) : EN 3660-002. NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-063. Temperature range, Class F (N) : 65 C to 200 C (see note above); Class K : 65 C to 200 C; Class W : 65 C to 175 C; Class T :
20、 65 C to 175 C (Nickel PTFE plating); Class Z : 65 C to 175 C (Zinc Nickel plating). Associated electrical accessories : prEN 3660-033 Metallic band (for shield termination). These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommoda
21、te/permit the termination of heat shrinkable boots. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edi
22、tion of the referenced document (including any amendments) applies. EN 2591- 1), Aerospace series Elements of electrical and optical connection Test methods EN 3645 (series), Aerospace series Connectors, electrical, circular, scoop-proof, triple start threaded coupling operating temperature 175 C or
23、 200 C continuous EN 3660-001, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 001: Technical specification EN 3660-002, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 002: In
24、dex of product standards prEN 3660-033, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 033: Stainless steel banding band, style Z, for attachment of individual and/or overall screens to cable outlets Product standard 2)EN 3909, Aerospace
25、 series Test fluids and test methods for electric components and sub-assemblies EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529) DIN 82, Knurling 1) All its parts quoted in this European Standard. 2) In preparation at the date of publication of this European Standard. BS
26、EN 3660-063:2015EN 3660-063:2015 (E) 5 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3660-001 apply. (Self-locking / anti-rotational definition) A self-locking or anti-rotational mechanism provides a nut rotation with a moderate torque in the mated
27、direction and provides a greater torque in the unmated direction. 4 Characteristics 4.1 Dimensions and mass For dimensions and mass, see Figures 1 and 2 and Tables 1 to 5 inclusive. For cable entry dimensions, see 4.2. All dimensions are in millimetres. Key 1 O-Ring 2 Thread C 3 Marking 4 Four tooli
28、ng holes spaced 90 apart. 2,60, depth, 1,27. 5 Straight knurl. Pitch manufacturers option. 6 Number of teeth N 7 RKV 08 DIN 82. Figure 2. (Please note there may be crossover dependent on diameter and pitch.) 8 Minimum penetration of D from the front of serrations. 9 Break edge NOTE 1 Cable outlets m
29、ay be manufactured as cast, fabricated or machined (manufactures option). NOTE 2 No sharp edges / burrs permissible on internal or external surfaces / joints. Surface finish of on all internal surfaces Figure 1 1,6 m max. BS EN 3660-063:2015EN 3660-063:2015 (E) 6 Table 1 Fixed dimensions of shell Di
30、mensions in millimetres Shell size A B C D E I N max. max. Thread min. max. min. Number of teeth 09 21,79 15,24 M12 1,0-6H0.100R 6,70 16,76 2,90 12 11 24,99 18,21 M15 1,0-6H0.100R 9,90 16,76 2,90 16 13 29,39 21,18 M18 1,0-6H0.100R 12,80 16,76 2,90 20 15 32,49 25,14 M22 1,0-6H0.100R 16,00 16,76 2,90
31、24 17 35,71 28,12 M25 1,0-6H0.100R 19,20 16,76 2,90 28 19 38,50 31,09 M28 1,0-6H0.100R 21,40 16,76 2,90 32 21 41,70 34,06 M31 1,0-6H0.100R 24,60 16,76 2,90 36 23 44,91 36,90 M34 1,0-6H0.100R 27,70 16,76 2,90 40 25 47,98 39,88 M37 1,0-6H0.100R 30,90 16,76 1,70 44 Table 2 Variable dimensions of wiring
32、 chamber Dimensions in millimetres Length code wiring chamber H J max. A 27,10 8,20 B 35,10 16,20 C 40,10 21,20 D 50,10 31,20 Table 3 Mass for classes F (N), W, T and Z (1 of 2) Nominal mass in grams Shell size code Cable entry size code Length code wiring chamber A B C D E F G H J K L M 09 10,7 11,
33、3 A 11,4 12,0 B 11,9 12,5 C 12,7 13,3 D 11 12,4 13,1 13,7 14,3 A 13,4 14,1 14,7 15,3 B 14,0 14,7 15,3 15,9 C 15,2 15,9 16,6 17,1 D BS EN 3660-063:2015EN 3660-063:2015 (E) 7 Table 3 Mass for classes F (N), W, T and Z (2 of 2) Nominal mass in grams Shell size code Cable entry size code Length code wir
34、ing chamber A B C D E F G H J K L M 13 14,5 14,9 15,3 16,1 16,6 17,2 A 15,7 16,2 16,6 17,3 17,9 18,4 B 16,5 16,9 17,4 18,1 18,7 19,2 C 18,1 18,5 18,9 19,6 20,2 20,7 D 15 17,8 18,2 18,6 19,0 19,2 20,0 21,2 A 19,3 19,7 20,1 20,5 20,8 21,6 22,7 B 20,3 20,7 21,1 21,4 21,7 22,5 23,7 C 22,2 22,6 23,0 23,3
35、 23,6 24,4 25,6 D 17 20,0 20,5 20,9 21,2 21,5 21,8 23,0 24,0 A 21,8 22,3 22,7 23,0 23,3 23,6 24,8 25,8 B 23,0 23,4 23,8 24,1 24,4 24,7 25,9 27,0 C 25,2 25,6 26,0 26,4 26,7 27,0 28,1 29,2 D 19 21,2 21,6 22,0 22,4 22,6 22,9 23,5 24,9 A 23,2 23,6 24,0 24,4 24,6 24,9 25,5 26,9 B 24,4 24,8 25,2 25,6 25,9
36、 26,2 26,7 28,2 C 26,9 27,3 27,7 28,1 28,4 28,7 29,2 30,6 D 21 25,7 26,1 26,5 26,9 27,2 27,5 28,0 28,4 29,6 A 28,0 28,4 28,8 29,2 29,4 29,7 30,3 30,7 31,9 B 29,4 29,8 30,2 30,6 30,9 31,2 31,7 32,1 33,3 C 32,3 32,7 33,1 33,4 33,7 34,0 34,6 35,0 36,2 D 23 27,1 27,5 27,9 28,3 28,5 28,8 29,4 29,8 30,3 3
37、1,3 A 29,6 30,0 30,4 30,8 31,1 31,4 32,0 32,3 32,9 33,8 B 31,2 31,6 32,0 32,4 32,7 33,0 33,5 33,9 34,5 35,4 C 34,4 34,8 35,2 35,6 35,9 36,2 36,7 37,1 37,7 38,6 D 25 33,1 33,5 33,9 34,3 34,5 34,9 35,4 35,8 36,4 36,6 37,7 A 35,9 36,4 36,8 37,1 37,4 37,7 38,3 38,6 39,2 39,4 40,5 B 37,7 38,1 38,5 38,9 3
38、9,2 39,5 40,0 40,4 41,0 41,2 42,3 C 41,3 41,7 42,1 42,4 42,7 43,0 43,6 44,0 44,5 44,7 45,8 D BS EN 3660-063:2015EN 3660-063:2015 (E) 8 Table 4 Mass for class K Nominal mass in grams Shell size code End-fitting size code Length code wiring chamber A B C D E F G H J K L M 09 26,9 28,5 A 28,7 30,3 B 29
39、,8 31,4 C 31,9 33,6 D 11 31,0 32,8 34,6 36,0 A 33,5 35,3 37,0 38,5 B 35,0 36,8 38,6 40,0 C 38,1 39,9 41,7 43,1 D 13 35,9 37,0 38,2 40,1 41,6 43,0 A 39,0 40,1 41,3 43,2 44,7 46,1 B 41,0 42,1 43,2 45,1 46,7 48,1 C 44,9 46,0 47,1 49,0 50,6 51,9 D 15 42,9 44,0 45,1 46,0 46,8 48,9 52,0 A 46,7 47,8 48,9 4
40、9,8 50,6 52,7 55,8 B 49,1 50,2 51,3 52,2 53,0 55,1 58,2 C 53,9 55,0 56,0 57,0 57,7 59,9 63,0 D 17 48,2 49,3 50,4 51,4 52,1 52,9 56,1 58,8 A 52,8 53,9 55,0 55,9 56,6 57,4 60,6 63,4 B 55,6 56,7 57,8 58,7 59,4 60,3 63,4 66,2 C 61,3 62,4 63,4 64,4 65,1 65,9 69,1 71,9 D 19 52,1 53,2 54,3 55,2 55,9 56,8 5
41、8,3 62,1 A 57,1 58,2 59,3 60,3 60,9 61,8 63,3 67,1 B 60,2 61,4 62,4 63,4 64,1 64,9 66,4 70,2 C 66,5 67,6 68,7 69,7 70,3 71,2 72,7 76,5 D 21 62,0 63,2 64,2 65,2 65,9 66,7 68,2 69,2 72,4 A 67,8 68,9 70,0 70,9 71,6 72,4 74,0 74,9 78,1 B 71,4 72,5 73,5 74,5 75,2 76,0 77,5 78,5 81,7 C 78,5 79,6 80,7 81,7
42、 82,3 83,2 84,7 85,7 88,8 D 23 66,1 67,2 68,3 69,2 69,9 70,8 72,3 73,3 74,7 77,0 A 72,5 73,6 74,7 75,6 76,3 77,2 78,7 79,7 81,1 83,4 B 76,5 77,6 78,7 79,7 80,3 81,2 82,7 83,7 85,1 87,5 C 84,5 85,6 86,7 87,7 88,4 89,2 90,7 91,7 93,1 95,5 D 25 78,6 79,8 80,8 81,8 82,5 83,3 84,8 85,8 87,3 87,7 90,7 A 8
43、5,8 86,9 88,0 88,9 89,6 90,4 91,9 92,9 94,4 94,8 97,8 B 90,2 91,3 92,4 93,4 94,1 94,9 96,4 97,4 98,8 99,3 102,3 C 99,1 100,2 101,3 102,3 103,0 103,8 105,3 106,3 107,7 108,2 111,2 D BS EN 3660-063:2015EN 3660-063:2015 (E) 9 4.2 Cable entry dimensions See Figure 2, Table 5. Figure 2 Cable entry Table
44、5 Dimensions in millimetres Cable entry size code A B C D Bundle/cable diameter 0,1 0,1 0,3 + 0,2 0 min. max. A 4,7 7,7 12,2 1,12 2,0 4,0 B 6,4 9,4 14,0 1,12 3,9 5,5 C 7,9 11,0 15,5 1,12 5,4 7,5 D 9,5 12,6 17,1 1,12 7,4 9,0 E 11,1 14,1 18,7 1,12 9,4 10,5 F 12,7 15,7 20,3 1,12 10,4 12,0 G 15,9 18,9 2
45、3,5 1,12 12,4 15,5 H 19,1 22,0 26,7 1,12 15,4 18,5 J 22,2 25,2 29,8 1,75 18,4 21,5 K 25,5 28,4 33,0 1,75 21,4 25,0 L 28,6 31,5 36,2 1,75 25,4 28,0 M 31,8 34,7 39,4 1,75 28,4 31,0 NOTE The cable entry shall be selected in accordance with the maximum diameter of the cable bundle. 4.3 Associated connec
46、tors See EN 3660-002. BS EN 3660-063:2015EN 3660-063:2015 (E) 10 4.4 Interface dimensions 4.4.1 Standard front interface See Figure 3 and Table 6. All dimensions are in millimetres. Detail A Key 1 See detail A Figure 3 Table 6 Dimensions in millimetres Shell size A B Ref. min. 09 10,57 7,5 11 13,56
47、10,8 13 16,58 13,8 15 20,57 16,9 17 23,57 20,1 19 26,57 22,8 21 29,57 26,0 23 32,56 29,1 25 35,56 32,3 BS EN 3660-063:2015EN 3660-063:2015 (E) 11 4.5 Material and finish NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-063. Material/Finish Class F (N) : Aluminium/Nickel plated (see note above) Material/Finish Class K : Stainless steel/Passivated Material/Fin