BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf

上传人:appealoxygen216 文档编号:550914 上传时间:2018-12-09 格式:PDF 页数:24 大小:401.62KB
下载 相关 举报
BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf_第1页
第1页 / 共24页
BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf_第2页
第2页 / 共24页
BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf_第3页
第3页 / 共24页
BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf_第4页
第4页 / 共24页
BS EN 3662-001-2006 Aerospace series - Circuit breakers three-pole temperature compensated rated current 20 A to 50 A - Part 001 Technical specification《航空航天系列 额定电流20 A~50 A的三极温度补偿.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARDBS EN 3662-001:2006Aerospace series Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A Part 001: Technical specificationThe European Standard EN 3662-001:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g5

2、6g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 3662-001:2006This British Standard was published un

3、der the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50003 9National forewordThis British Standard was published by BSI. It is the UK implementation of EN 3662-001:2006. The UK participation in its preparation was entrusted by Technical Committee

4、 ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a

5、 contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEUROPEAN S

6、TANDARDNORME EUROPENNEEUROPISCHE NORMEN 3662-001August 2006ICS 49.060English VersionAerospace series - Circuit breakers, three-pole, temperaturecompensated, rated current 20 A to 50 A - Part 001: TechnicalspecificationSrie arospatiale - Disjoncteurs tripolaires compenss entemprature, intensits nomin

7、ales 20 A 50 A - Partie 001: Spcification techniqueLuft- und Raumfahrt - Schutzschalter, dreipolig,Temperaturkompensiert, Nennstrme von 20 A bis 50 A -Teil 001: Technische LieferbedingungenThis European Standard was approved by CEN on 10 May 2006.CEN members are bound to comply with the CEN/CENELEC

8、Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN mem

9、ber.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members ar

10、e the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and Un

11、ited Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3662-001:2006:

12、 ELicensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Description .5 5 Design .5 6 Characteristics.6 7 Tests8 8 Qualification tests16 9 Quality assurance19 10 Marking .19

13、11 Delivery conditions20 12 Packaging .20 13 Storage20 EN 3662-001:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI3 Foreword This European Standard (EN 3662-001:2006) has been prepared by the Aerospace and Defence Industries Association of Europe - Sta

14、ndardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard sha

15、ll be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention is drawn to the possibility that some of the elements of this d

16、ocument may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standar

17、d: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 3662-001:

18、2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI4 1 Scope This standard specifies the three-pole temperature compensated circuit breakers with signal contacts, polarized or not, rated from 20 A to 50 A and used in aircraft on-board circuits. It describe

19、s specific environmental, electrical and mechanical characteristics and the stringency of tests to be applied according to test methods of EN 3841-100. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282 (all categories). 2 Normative references

20、 The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2083, Aerospace series Copper or copper alloy

21、 conductors for electrical cables Product standard. EN 2282, Aerospace series Characteristics of aircraft electrical supplies. EN 2825, Aerospace series Burning behaviour of non metallic materials under the influence of radiating heat and flames Determination of smoke density.1)EN 2826, Aerospace se

22、ries Burning behaviour of non metallic materials under the influence of radiating heat and flames Determination of gas components in the smoke.1)EN 3662-005, Aerospace series Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A Part 005: With polarized signal contact Pro

23、duct standard. EN 3662-006, Aerospace series Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A Part 006: With polarized signal contact Bus-bar version Product standard. EN 3841-100*, Aerospace series Circuit breakers Test Methods Part 100: General. EN 3844-1, Aerospac

24、e series Flammability of non metallic materials Part 1: Small burner test, vertical Determination of the vertical flame propagation.1)EN 9133, Aerospace series Quality management systems Qualification Procedure for Aerospace Standards Parts. TR 6083, Aerospace series Cut-outs for installation of ele

25、ctrical components.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B.3) *And all its parts quoted. 1) Published as AECMA Presta

26、ndard at the date of publication of this standard. 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. EN 3662-001:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 200

27、7, Uncontrolled Copy, (c) BSI5 3 Terms and definitions For the purposes of this standard, the terms and definitions given in EN 3841-100 apply. 4 Description These circuit breakers are operated by a “push-pull“ type single pushbutton (actuator) and with delayed action “trip-free“ tripping. Their fun

28、ction is assured up to the short-circuit current. 5 Design 5.1 Materials 5.1.1 Metallic materials All metallic parts shall be resistant to corrosion or finished against corrosion. When dissimilar materials are in close contact, an adequate protection against corrosion shall be used so that the elect

29、romotive force of the galvanic couple does not exceed 0,25 V. When bimetals are used, an eventual corrosion shall not affect the good operation of the circuit breaker. 5.1.2 Insulation materials The insulating parts shall be made of auto-extinguishing or non-flammable materials; they shall not emit

30、damaging or explosive vapours, even in presence of fire or internal electric arc. They shall be insensitive to moulds and micro-organisms action. Application of any material or protective coating, which might crack, break or flake shall be forbidden. Materials which are not specified or which are no

31、t specially described shall be as light as possible for the requested use. Materials shall be selected according to security criteria (toxicity, smoke density) as defined in contractual documents. 5.2 Design 5.2.1 Insulating box The insulating box shall integrate besides the mechanism, the connectio

32、n and attachment unit. 5.2.2 Free release mechanism Design of circuit breaker mechanism shall allow free release; i.e. the circuit breaker cuts out in case of overload, and remains cut out even if the actuator is kept by force in engaged position. A new engagement of circuit breaker is only possible

33、 after a first total release of the control actuator. The operation in these conditions shall not affect further performances of the circuit breaker. 5.2.3 Attachment All visible parts shall be black coloured and non-reflective. EN 3662-001:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00

34、:00 2007, Uncontrolled Copy, (c) BSI6 5.2.4 Electrical connection units They shall be able to receive the lugs (or contacts). 5.2.5 Control actuator In engaged position, the visible part of the control actuator shall be of the colour stated in the product standard. In disengaged (or opened) position

35、, the control actuator shall show a white strip. The outer part of this actuator shall be isolated from all under voltage parts. The control actuator shall not stay in a transition position, or give a false indication about the circuit breaker condition. It shall not be removable. When pushing it, p

36、ower contacts of the circuit breaker engage and indicating contact opens. When pulling it, power contacts of the circuit breaker open and indicating contact closes. The circuit breaker rating is indicated in indelible white colour on the front part of the control actuator. The product standard gives

37、 the digits positioning. 5.2.6 Rating inviolability The circuit breaker shall be designed in such a way that the calibration unit cannot be reached without breaking a sealing. 5.2.7 Leakage lines The leakage lines and the minimal space to be foreseen between the under voltage parts and any other par

38、t of the circuit breaker made of non-insulating material, as well as between the under voltage parts of opposite polarity, shall be sufficient to avoid any default or arc tracking in all uses and climatic conditions. 5.2.8 Protection against non-release Electrical overload happening on a circuit bre

39、aker locked in its engaged position (sticked contacts or non-operating release mechanism), shall cause the opening of the circuit by circuit breaker destruction without any fire or important smoke release. 6 Characteristics 6.1 General characteristics See Table 1. EN 3662-001:2006Licensed Copy: Wang

40、 Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI7 Table 1 General characteristics Designation Requirements Assembly See product standard. Mass See product standard. Operational altitude See product standard. Power contact connection 3 input terminals on power supply side (ide

41、ntified by digit A1, B1, C1) 3 output terminals on distribution side (identified by digit A2, B2, C2) See product standard. Signal contact connection, circuit closed when circuit breaker is on release Crimp contacts size 20 See product standard. Operational ambient temperatures limits From 55 C to 9

42、0 C Temperature compensation From 55 C to 90 C See product standard. Rating marking On control actuator (indelible white) 6.2 Ratings See product standard. 6.3 Nominal voltage of main contacts See product standard. 6.4 Signal contact performances See Table 2. Table 2 Signal contact performances Type

43、 of load 28 V d.c. 5 V d.c. 5 V a.c. a28 V d.c. Resistive 0,5 A 3 mA Not used 3 mA Signal contact Lamp 0,2 A Not used 0,23 A Not used aApplicable on version without diode only. NOTE 1 The circuit breaker status signalling function, open or closed shall be guaranteed after all the tests described in

44、this specification. NOTE 2 In order to avoid any deterioration of the signalization circuit (contact and diode), the reception electrical test could be performed without exceeding the value recommended of 60 mW max. at 28 V d.c. max. (resistive load). EN 3662-001:2006Licensed Copy: Wang Bin, na, Thu

45、 Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI8 6.5 Dimensional characteristics See product standard. 6.6 Recommended panel mounting dimensions Panel cut-out : The panel cut-out is in accordance with the designations TR6083C202 (for EN 3662-005) and TR6083C400 (for EN 3662-006). Spacing

46、 : 60 mm horizontal and 45 mm vertical from the centres of the mounting holes. Panel thickness : 1 mm to 3 mm. 7 Tests 7.1 Mechanical tests See Table 3. Table 3 Mechanical tests Tests Requirements Visual check See EN 3841-201. Closing force (push) 20 N to 80 N Operational force Opening force (pull)

47、See EN 3841-502. 5 N to 45 N Travel See EN 3841-501. For value, see product standard. Transverse load 110 N Push 110 N Actuator Longitudinal load Pull See EN 3841-503. 110 N Tightening torque 5,5 N.m Attachment nut Rotation torque See EN 3841-504. 3 N.m Screw tightening torque 2,5 N.m Tensile force

48、as per F1(see Figure 1 in product standard). 110 N Main contact connection Pressure force as per F2(see Figure 1 in product standard) See EN 3841-505. 55 N See product standard. Insertion force Insertion possible without tools 6 N Extraction force See EN 3841-509. 15 N Contact retention force (pre-l

49、oad 13,5 N) See EN 3841-510. 67 N shift 0,3 mm Radial load See EN 3841-510. 30 N Mechanical strength Signal contact connection (size 20) Recommended tools: - plastic: MIL-I-81969/14-11 - metallic: MIL-I-81969/1-02 See MIL-I-81969/1A and MIL-I-81969/14C EN 3662-001:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:31:24 GMT+00:00 2007, Uncontrolled Copy, (c) BSI9 7.2 Environmental tests See Table 4. Table 4 Environmental conditions Tests Requirements 5 Hz to 80 Hz - Constan

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1