BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf

上传人:李朗 文档编号:551680 上传时间:2018-12-09 格式:PDF 页数:14 大小:708.04KB
下载 相关 举报
BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C  Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf_第1页
第1页 / 共14页
BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C  Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf_第2页
第2页 / 共14页
BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C  Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf_第3页
第3页 / 共14页
BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C  Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf_第4页
第4页 / 共14页
BS EN 4604-008-2009 Aerospace series — nCable electrical for nsignal transmission nPart 008 Cable coaxial 50 ohms n200C  Type WD — Product standard《航空航天系列 信号传输用电缆 第008部分 WD型50Ω 200.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS EN4604-008:2009ICS 49.060NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAerospace series Cable, electrical, forsignal transmissionPart 008: Cable, coaxial, 50 ohms,200C., Type WD Product standardThis British Standardwas published underthe authority of theSta

2、ndards Policy andStrategy Committee on 30September 2009 BSI 2009ISBN 978 0 580 63701 8Amendments/corrigenda issued since publicationDate CommentsBS EN 4604-008:2009National forewordThis British Standard is the UK implementation of EN 4604-008:2009.The UK participation in its preparation was entruste

3、d to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its

4、 correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 4604-008:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 4604-008 August 2009 ICS 49.060 English Version Aerospace series - Cable, electrical, for signal transmission - Part 008: Cable

5、, coaxial, 50 ohms, 200 C., Type WD - Product standard Srie arospatiale - Cbles lectriques pour transmission de signaux - Partie 008: Cble, coaxial, 50 ohms, 200 C, type WD - Norme de produit Luft- und Raumfahrt - Elektrische Leitungen fur Signalubertragungen - Teil 008: Koaxialkabel, 50 Ohm, 200 C,

6、 Typ WD - Produktnorm This European Standard was approved by CEN on 20 June 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and

7、bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibi

8、lity of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland

9、, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Ma

10、rnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4604-008:2009: EBS EN 4604-008:2009EN 4604-008:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Requir

11、ed characteristics .4 5 Quality assurance . 10 6 Designation . 10 7 Identification and marking . 11 8 Packaging, labelling and delivery lengths . 11 9 Technical specification 11 BS EN 4604-008:2009EN 4604-008:2009 (E) 3 Foreword This document (EN 4604-008:2009) has been prepared by the Aerospace and

12、 Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its

13、presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2010, and conflicting national standards shall be withdrawn at the latest by February 2010. Attention is drawn to the

14、possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countri

15、es are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,

16、 Sweden, Switzerland and the United Kingdom. BS EN 4604-008:2009EN 4604-008:2009 (E) 4 1 Scope This standard specifies the required characteristics of a coaxial cable, 50 , type WD, for use in aircraft electrical systems at operating temperature between 55 C and 200 C and specially for high frequenc

17、y up to 8 GHz. Nevertheless, if needed, 65 C is also acceptable as shown by thermal stability test. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the late

18、st edition of the referenced document (including any amendments) applies. EN 3475-100*, Aerospace series Cables, electrical, aircraft use Test methods Part 100: General. EN 4604-001, Aerospace series Cable, electrical, for signal transmission Part 001: Technical specification. EN 4604-002, Aerospace

19、 series Cable, electrical, for signal transmission Part 002: General. TR 6058, Aerospace series Cable code and identification list. 1)ASTM-B298-99, Standard specification for silver-coated soft or annealed copper wire. 2)3 Terms and definitions For the purposes of this document, the terms and defini

20、tions given in EN 3475-100 apply. 4 Required characteristics 4.1 Material, constructions, dimension and mass 4.1.1 Material See Table 1. Table 1 Material Material Finish Colour Conductor Multi-strands copper per ASTM-B298-99 Class A silver plated Dielectric Fluorocarbon Shield 2 braids, copper per A

21、STM-B298-99. Class A silver plated Jacket Fluorocarbon white *And all parts quoted in this standard. 1) Published as ASD Technical Report at the date of publication of this standard. 2) Published by: American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive,. PO Box C700, West Conshoh

22、ocken, PA 19428-2959 USA. BS EN 4604-008:2009EN 4604-008:2009 (E) 5 4.1.2 Construction, dimensions and mass See Figure 1 and Table 2. EN WD FR F 01ConductorDielectricShieldJacketKey 1 Conductor 2 Dielectric 3 Shield 4 Jacket Figure 1 Construction Table 2 Dimensions and mass Diameter (mm) Mass Conduc

23、tor Dielectric Shield Cable g/mmin. max. nom. max. 2,33 0,05 (37 0,34) mm 5,9 6,1 7,1 0,1 7,70 0,20 130 137 Shield strand diameter shall be 0,13 mm. 4.2 General characteristics a) Operating temperature: 55 C to 200 C b) Minimum bend radius: 1) in static use: 40 mm 2) in dynamic use: 80 mm c) Perform

24、ances are guaranteed up to 8 GHz. 4.3 Electrical characteristics a) Characteristic impedance: Zc = (50 2) at 200 MHz b) Capacitance per unit length: Cp = 85 pF/m WD FR F 01 2 3 4 BS EN 4604-008:2009EN 4604-008:2009 (E) 6 c) Transfer impedance: see Table 4. d) Operating voltage: 1 000 V RMS max. e) M

25、aximum power handling (at sea level): See Table 3. f) Attenuation versus frequency: See Table 3. g) Velocity of propagation: 240 000 km/s (Vr = 80 %) min. Table 3 Frequency, attenuation, power handling and VSWR Frequency MHz 50 100 150 200 400 1 000 1 600 2 500 3 000 8 000Attenuation max. dB/100 m 5

26、,0 7,2 9,1 10,7 16,1 28,6 39,6 55,0 61,0 110,0Attenuation nom. dB/100 m 4,6 6,5 8,3 9,7 14,6 26,0 36,0 50,0 55,0 105,0Power cw nom. W 5 700 4 000 3 100 2 700 1 800 1 000 730 530 480 250 Max. return loss VSWR 1,10 1,15 1,20 1,35 Table 4 Frequency, transfer impedance Frequency MHz 0 to 0,01 0,1 1 5 10

27、 30 100 Transfer impedance Zt max. m/m 4,2 4 1,3 0,6 1,0 2,3 5,5 4.4 Tests See Table 5. BS EN 4604-008:2009EN 4604-008:2009 (E) 7 Table 5 EN 3475- Designation of the test Remarks 201 Visual examination 202 Mass Applicable 137 g/m max. 203 Dimensions Applicable See 4.1 and Table 2. 301 Ohmic resistan

28、ce per unit length Applicable 5,5 /km 302 Voltage proof test Applicable Dielectric Dry test: 2 500 V AC Jacket Dry impulse: 5 000 V Dry test: 1 750 V AC 303 Insulation resistance Applicable 5 000 M.km between shield and conductor304 Surface resistance Not applicable 305 Overload resistance Not appli

29、cable 306 Continuity of conductors Applicable 307 Corona extinction voltage Applicable Extinction voltage 1 500 V 401 Accelerated ageing Not applicable 402 Shrinkage and delamination Not applicable 403 Delamination and blocking Not applicable 404 Thermal shock Not applicable 405 Bending at ambient t

30、emperature Not applicable 406 Cold bend test Not applicable 407 Flammability Applicable. Method 1. Load = 20 N Extinction time 10 m Load application time = 2 minutes Attenuation: See Table 3. Impedance: See 4.3. VSWR: See Table 3. 601 Smoke density Applicable 602 Toxicity Applicable 603 Resistance t

31、o wet arc tracking Not applicable 604 Resistance to dry arc propagation Not applicable 605 Wet short circuit test Not applicable 701 Strippability and adherence of insulation to conductor Applicable 15 N to 75 N 702 Screen pushback capability Applicable 703 Permanence of manufacturers marking Applic

32、able Except when marking on tape between shield and jacket 704 Flexibility The force to crush the loop by 25 % shall be 10 N maximum. continued BS EN 4604-008:2009EN 4604-008:2009 (E) 10 Table 5 (concluded) EN 3475- Designation of the test Remarks 705 Contrast measurement Not applicable 706 Laser ma

33、rkability Not applicable 801 Capacitance per unit length Applicable See 4.3. 802 Capacitance unbalance Not applicable 803 Capacitance variation Not applicable 804 Velocity of propagation Applicable See 4.3. 805 Characteristics impedance Applicable See 4.3. 806 Attenuation Applicable See 4.3, Table 3

34、. 807 Transfer impedance Applicable See Table 4. 808 Cross-talk Not applicable 809 Resistance unbalance Not applicable 810 Structural return loss Not applicable 811 Unbalance attenuation Not applicable 812 Return loss (VSWR) Applicable See 4.3 and Table 3. 5 Quality assurance See EN 4604-001. 6 Desi

35、gnation EXAMPLE Description blockCABLE, COAXIAL Identity blockEN4604-008WD Number of this standard Cable code (see TR 6058) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. BS EN 4604-008:2009EN 4604-008:2009 (E) 11 7 Identification and marking

36、Colour of the marking shall be black or green. See EN4604-002 8 Packaging, labelling and delivery lengths 8.1 Packaging and labelling See EN 4604-001. 8.2 Delivery lengths Delivery on cable drums (about 100 metres). Minimum length of each piece: 30 metres. / 2 pieces per drum. 9 Technical specificat

37、ion See EN 4604-001. BS EN4604-008:2009BSI GroupHeadquarters 389Chiswick High Road,London, W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 - British Standards InstitutionBSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Euro

38、pe and at theinternational level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products an

39、d services.We would be grateful if anyone finding an inaccuracy or ambiguity while usingthis British Standard would inform the Secretary of the technical committeeresponsible, the identity of which can be found on the inside front cover. Tel:+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers m

40、embers an individual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should beaddressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)2

41、0 89967001 Email: You may also buy directly using a debit/creditcard from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI policy to supply theBSI implementation of those that have been published as British Standards,unless otherwise requested.Information

42、 on standardsBSI provides a wide range of information on national, European andinternational standards through its Library and its Technical Help to ExportersService. Various BSI electronic information services are also available whichgive details on all its products and services. Contact Informatio

43、n Centre. Tel:+44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standards developmentsand receive substantial discounts on the purchase price of standards. For detailsof these and other benefits contact Membership Administration. Tel: +44 (0)2089

44、96 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via British StandardsOnline can be found at http:/ information about BSI is available on the BSI website at http:/.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in th

45、eUK, of the publications of the international standardization bodies. Except aspermitted under the Copyright, Designs and Patents Act 1988 no extract maybe reproduced, stored in a retrieval system or transmitted in any form or by anymeans electronic, photocopying, recording or otherwise without prio

46、r writtenpermission from BSI.This does not preclude the free use, in the course of implementing the standard,of necessary details such as symbols, and size, type or grade designations. Ifthese details are to be used for any other purpose than implementation then theprior written permission of BSI must be obtained.Details and advice can be obtained from the Copyright and Licensing Manager.Tel: +44 (0)20 8996 7070 Email:

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1