1、BS EN4626-001:2008ICS 49.060NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAerospace series Connectors,optical, rectangular,multicontact, rack andpanel, Quadrax cavity,2,5 mm diameterferrule Operatingtemperatures 65C to 125 C (cabledependent) FlushcontactsPart
2、001: Technical specificationThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 32008 BSI 2008ISBN 978 0 580 60586 4Amendments/corrigenda issued since publicationDate CommentsBS EN 4626-001:2008National forewordThis British Standard is the UK impleme
3、ntation of EN 4626-001:2008.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to
4、include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.0 SeptemberBS EN 4626-001:2008EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 4626-001 August 2008 ICS 49.060 Engl
5、ish Version Aerospace series - Connectors, optical, rectangular, multicontact, rack and panel, Quadrax cavity, 2,5 mm diameter ferrule - Operating temperatures - 65 C to 125 C (cable dependent) - Flush contacts - Part 001: Technical specificationSrie arospatiale - Connecteurs, optique, rectangulaire
6、, contacts multiples, rackables, cavit Quadrax, ferrule diamtre 2,5 mm - Temprature dutilisation - 65 C 125 C (selon cble) - Contacts affleurants - Partie 001: Spcification technique Luft- und Raumfahrt - Optische Rechtecksteckverbinder, Quadrax-Kontaktkammer, Durchmesser 2,5 mm Ferrule - Betriebste
7、mperaturen - 65 C bis 125 C (vom Kabel abhngig) - Bndige Kontakte - Teil 001: Technische Lieferbedingungen This European Standard was approved by CEN on 28 December 2007. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
8、 Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English,
9、French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyp
10、rus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION C
11、OMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4626-001:2008: EBS EN 4626-001:2008EN 4626-001:2008 (E) 2 Cont
12、ents Page Foreword3 Introduction .4 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Description .5 5 Design .5 6 Drawings.6 7 Tests9 8 Quality assurance12 9 Designation and marking15 BS EN 4626-001:2008EN 4626-001:2008 (E) 3 Foreword This document (EN 4626-001:2008) has been prepared
13、 by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries
14、of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2009, and conflicting national standards shall be withdrawn at the latest by February 2009. Atten
15、tion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of
16、the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slova
17、kia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 4626-001:2008EN 4626-001:2008 (E) 4 Introduction This family of fibre optic contact sub-assemblies are suitable for use in ARINC 600 connectors with size 8 Quadrax cavities in aerospace onboard applications. It provides easy acc
18、ess for optical contact end face cleaning. 1 Scope This standard specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups for fibre sub-assembly contact in rack and panel connectors, intended for use in a tempe
19、rature range from 65 C to 125 C continuous (cable dependent). This standard specifies a pair of adaptors to fit with standard Quadrax cavities and EN 4531-101 optical contact. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated
20、references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591-100*, Aerospace series Elements of electrical and optical connection Test methods Part 100: General EN 3197, Aerospace series Installation of
21、aircraft electrical and optical interconnection systems 1)EN 4531-101, Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring Flush contacts Part 101: Optical contact for EN 4641-100 cable 55 C to 125 C Product standard 1)EN 4626-002, Aerospace series Connector
22、s, optical, rectangular, multicontact, rack and panel, Quadrax cavity, 2,5 mm diameter ferrule Operating temperatures 65 C to 125 C (cable dependent) Flush contacts Part 002: Specification of performance and contact arrangements EN 9133, Aerospace series Quality management systems Qualification proc
23、edure for aerospace standard parts ARINC 600, Air transport avionics Equipment interfaces 2)3 Terms and definitions For the purposes of this standard, the terms, definitions and abbreviations given in EN 2591-100 apply. *And all its parts quoted in this standard. 1) Published as ASD Prestandard at t
24、he date of publication of this standard. 2) Published by: Aeronautical Radio, Inc. 2551 Riva road, Annapolis, Maryland 21401. BS EN 4626-001:2008EN 4626-001:2008 (E) 5 4 Description 4.1 Optical sub-assembly and adaptor The optical sub-assembly comprises of an EN 4531-101 fibre optic contact, male an
25、d female adaptors allowing positioning of the fibre optic contact in either a plug or receptacle Quadrax size 8 cavity or a single part which integrates the EN 4531-101 contact and adaptor. The female adaptor is characterised by the integral alignment sleeve providing precise alignment of the optica
26、l ferrules. The optical contact sub-assemblies are polarized by means of keyways in the adaptors and keys on the contact body. 4.2 Materials and surface treatment 4.2.1 Requirements When dissimilar metals are in close contact, adequate protection against corrosion shall be used for the electromotive
27、 force of the cell not to exceed 0,25 V (see EN 3197). 4.2.2 Housing and inserts The connector housing and insert arrangement information are detailed in ARINC 600 standards. 4.2.3 Optical contacts Details of the optical contacts and alignment sleeves are detailed in EN 4531-101. 4.2.4 Adaptor The a
28、daptor shall be of suitable material as specified in the product standard. 5 Design 5.1 Housing Connector housing is defined in the ARINC 600 standard. Quadrax cavity arrangements will be defined in Technical Report in preparation. 5.2 Optical contact See EN 4531-101. 5.3 Adaptor The adaptor is desi
29、gned to provide mechanical retention and accurate alignment of the EN 4531-101 fibre optic contact within an ARINC 600 housing containing Quadrax size 8 cavities. The adaptor is keyed and mechanically retained in the ARINC 600 Quadrax size 8 insert cavity. The design permits installation of individu
30、al adaptors and contacts without removal of the connertor insert. Fitting and removal of the adaptor will be from the rear of the connector insert using the tool specified in the relevant adaptor product standard. BS EN 4626-001:2008EN 4626-001:2008 (E) 6 5.4 Connector and optical contact coupling s
31、equence During normal coupling the mechanical properties of the connectors provide the following coupling sequence: Shells Polarizing keys Optical contacts Adaptor. Refer to the ARINC 600 specification for mechanical interconnecting requirements. 6 Drawings 6.1 Definition drawings The general interm
32、ateability dimensions of receptacles and plugs are given below. Optical contact dimensions are defined in the product standard. 6.2 Coupling condition The stated dimensions are included to ensure that no mechanical interference occurs between the ferrule of the female adaptor and male adaptor body d
33、uring the coupling cycle. See Figure 1. Figure 1 BS EN 4626-001:2008EN 4626-001:2008 (E) 7 6.3 Contact mating dimensions with male Quadrax insert (unmated position) See Figure 2. 5.07 0.247.20 0.34Figure 2 BS EN 4626-001:2008EN 4626-001:2008 (E) 8 6.4 Optical contact mating dimensions with female Qu
34、adrax insert (unmated position) See Figure 3. 1.00 0.401.45 0.38Figure 3 BS EN 4626-001:2008EN 4626-001:2008 (E) 9 6.5 Displacement of the optical contact in the connector (mated position) See Figure 4. 5.43 1.21Figure 4 7 Tests 7.1 Tests according to EN 2591-100 standard The tests of EN 2591-100, a
35、pplicable in the context of this standard as well as the details necessary for implementing them and for inspecting connector characteristics, are given in Table 1. BS EN 4626-001:2008EN 4626-001:2008 (E) 10 Table 1 EN 2591- Designation of the test Details 6101 Visual examination No loosening of par
36、ts, cracks, excessive wear or detached parts. Optical face undamaged and free from contamination when examined at 100 magnification minimum. 101 Visual examination Not applicable 102 Examination of dimensions and mass According to Clause 6 and product standard. NOTE In the case of a qualified inspec
37、tion system, the parts unrelated to a production batch, may be used. 6301 Endurance at temperature For performance and test method requirements refer to the applicable product standard for the component and cable under test. 302 Climatic sequence Not applicable (already cover by EN 4531-101) 6303 Co
38、ld/low pressure and damp heat Not applicable (already cover by EN 4531-101) 304 Damp heat steady state Not applicable 6305 Rapid change of temperature For performance and test method requirements refer to the applicable product standard for the component and cable under test. 6306 Mould growth Not a
39、pplicable 6307 Salt mist 48 hours 308 Sand and dust Not applicable 309 Dry heat Not applicable 310 Cold Not applicable 311 Low air pressure Not applicable 312 Air leakage Not applicable 313 Driving rain (artificial) Not applicable 6314 Immersion at low air pressure Not applicable 6315 Fluid resistan
40、ce Not applicable (already cover by EN 4531-101) 6316 Ozone resistance Not applicable 6317 Flammability Not applicable 6318 Fire resistance Not applicable 319 Gastightness of solderless wrapped connections Not applicable 320 Simulated solar radiation at ground level Not applicable 6321 Damp heat, cy
41、clic test For performance and test method requirements refer to the applicable product standard for the component and cable under test (in place of test EN 2591-304) 6323 Thermal shock (Hermetically sealed devices) Not applicable continued BS EN 4626-001:2008EN 4626-001:2008 (E) 11 Table 1 (continue
42、d) EN 2591- Designation of the test Details 6324 Interfacial sealing Not applicable 325 Ice resistance Not applicable 6401 Acceleration steady state Not applicable 6402 Shock Method A, severity 50, 11 ms. 6403 Vibrations Method B, Figure 3, Table 2, level E. Two axes (X and Y), 8 hours/axe (checked
43、with ARINC 600). 6404 Transverse load Not applicable 6405 Axial load Not applicable 6406 Mechanical endurance 500 cycles for connector Subclause 7.2 Additional test: optical maintenance ageing: 10 cycles. 407 Durability of contact retention system and seals Not applicable 408 Mating and unmating for
44、ces Any configuration of layout must not exceed the maximum value defined in ARINC 600 specification for mating force. 409 Contact retention in insert Not applicable 410 Insert retention in housing (axial) Not applicable 411 Insert retention in housing (torsional) Not applicable 412 Contact insertio
45、n and extraction forces Not applicable 6414 Unmating of lanyard release optical connection elements Not applicable 6415 Test probe damage Not applicable 427 Robustness of protective cover attachment Not applicable 601 Insertion loss For performance and test method requirements refer to the applicabl
46、e product standard for the component and cable under test. 602 Variation of attenuation and optical discontinuity For performance and test method requirements refer to the applicable product standard for the component and cable under test. 603 Change of power distribution Not applicable 604 Cleaning
47、 capability of optical face For performance and test method requirements refer to the applicable product standard for the component and cable under test. 605 Return loss For performance and test method requirements refer to the applicable product standard for the component and cable under test. cont
48、inued BS EN 4626-001:2008EN 4626-001:2008 (E) 12 Table 1 (concluded) EN 2591- Designation of the test Details 607 Immunity to ambient light coupling Not applicable 609 Effectiveness of cable attachment - Cable cyclic flexing Not applicable 610 Effectiveness of cable attachment - Cable pulling Not ap
49、plicable 611 Effectiveness of cable attachment - Cable torsion Not applicable 612 Effectiveness of cable attachment - Cable axial compression Not applicable 613 Impact test Not applicable 614 Connector radial compression Not applicable 615 Connection integrity at temperature Not applicable (cover by test EN 2591-6301) 617 Temperature cycling Not applicable (cover by test EN 2591-6305) 7.2 Additional test Maintenance ageing: one cycle is defined as the insertion and extraction of the contact in