1、BSI Standards PublicationAerospace series Connectors, coaxial, radio frequencyPart 210: Type 2, TNC interface Clamp nut assembly version Straight plug Product standardBS EN 4652-210:2015National forewordThis British Standard is the UK implementation of EN 4652-210:2015.The UK participation in its pr
2、eparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optic technology.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users
3、are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 89863 1ICS 49.060 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theSt
4、andards Policy and Strategy Committee on 31 December 2015. Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 4652-210:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 4652-210 December 2015 ICS 49.060 English Version Aerospace series - Connectors, coaxial,
5、 radio frequency - Part 210: Type 2, TNC interface - Clamp nut assembly version - Straight plug - Product standard Srie arospatiale - Connecteurs coaxiaux pour radio frquences - Partie 210 : Type 2, interface TNC - Version presse toupe - Fiche droite - Norme de produit Luft- und Raumfahrt - Koaxiale
6、 Hochfrequenz-Steckverbinder - Teil 210: Typ 2, TNC-Anschluss - Klemmverbindung - freier Steckverbinder, gerade - Produktnorm This European Standard was approved by CEN on 6 June 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
7、 this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three offici
8、al versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of A
9、ustria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sw
10、eden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for C
11、EN national Members. Ref. No. EN 4652-210:2015 EBS EN 4652-210:2015EN 4652-210:2015 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions . 4 4 Required characteristics 4 5 Test methods 8 6 Qualification 11 7 Quality assurance 12 8 Designation . 12 9 Mark
12、ing . 12 10 Packaging . 12 11 Storage 12 BS EN 4652-210:2015EN 4652-210:2015 (E) 3 European foreword This document (EN 4652-210:2015) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with
13、 the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of
14、an identical text or by endorsement, at the latest by June 2016 and conflicting national standards shall be withdrawn at the latest by June 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held
15、 responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
16、 Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 4652-210:2015EN 4652-
17、210:2015 (E) 4 1 Scope This European Standard specifies the characteristics of screwed on coupling (TNC interface) coaxial straight plugs 50 ohms. The cable to connector assembly is a clamp technology. 2 Normative references The following documents, in whole or in part, are normatively referenced in
18、 this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591 1), Aerospace series Elements of electrical and optical connection Test me
19、thods EN 2812, Aerospace series Stripping of electric cables EN 4652-001, Aerospace series Connectors, coaxial, radio frequency Part 001: Technical specification EN 4652-212, Aerospace series Connectors, coaxial, radio frequency Part 212: Type 2, TNC interface Clamp nut assembly version Square flang
20、e receptacle Product standard EN 4652-213, Aerospace series Connectors, coaxial, radio frequency Part 213: Type 2, TNC interface Clamp nut assembly version Bulkhead receptacle Product standard EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard parts T
21、R 6058, Aerospace series Cable code identification list 2)3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 4652-001 apply. 4 Required characteristics The connection technology shall comply to required tests described in Clause 5. Interface shall comply
22、 to EN 4652-001. A self-locking device on plugs shall be proposed if hole for lockwire do not exist. Water ingress resistance is required in mated conditions for all cable groups. Water ingress resistance is required in unmated condition for cable group A. 1) All parts quoted in this standard. 2) Pu
23、blished as ASD-STAN Technical Report at the date of publication of this standard. http:/www.asd-stan.org/ BS EN 4652-210:2015EN 4652-210:2015 (E) 5 4.1 Configuration, dimension and mass Mass without heat shrink tubing. See Figure 1 and Table 1. Dimensions in millimetres Key 1 Flat 10 2 Marking 3 3 h
24、oles for lockwire 1 4 HEX. 14 5 HEX. F Figure 1 TNC straight plug Marking: see Clause 9. Table 1 TNC straight plug dimensions and mass Cable group A C D E HEX. F Interface style Mass (cable jacket) (cable conductor) (according to EN 4652-001) g max. max. max. max. A 43,6 7,8 2,3 15 12 Style C 35,7 B
25、 35,9 5,55 1,4 13 8 Style C 25,2 BS EN 4652-210:2015EN 4652-210:2015 (E) 6 4.2 Materials and finish Centre contact . : Copper alloy gold plated over nickel undercoat Insulators : PTFE Seals . : Silicone rubber or silicone fluoride Body : Copper alloy, nickel plated Heat shrink tube . : Polyolefin Co
26、upling nut, rear screw and other parts materials shall have mechanical and electrical characteristics consistent with the requirements of this product standard. 4.3 Temperature Operating temperature shall be between 65 C and 165 C. 4.4 Electrical characteristics Impedance : 50 Maximum operating freq
27、uency : 6 GHz VSWR : 1,15 up to 6 GHz Insertion loss . : 0,04f dB max., f in GHz Contact resistance (initial centre contact) : 1,5 m max. Insulation resistance : 5 000 M min. Withstand voltage . : 1 500 Veff (at sea level) 4.5 General characteristics Tightening torque of coupling nut : 2,6 Nm 0,3 Nm
28、 Force to engage or disengage . : 0,23 Nm max. Service life . : 500 cycles Retention of centre contact . : 27 N min. Retention of cable : see Table 2. BS EN 4652-210:2015EN 4652-210:2015 (E) 7 Table 2 Retention of cable Cable group Retention of cable N min. A 180 B 180 4.6 Admissible cables, tools a
29、nd stripping lengths See Table 3 to Table 5. Table 3 Stripping lengths Cable group Cable code (see TR 6058) Stripping lengths mm A KW B KX Table 4 Stripping lengths cable group A A B min. mm max. mm min. mm max. mm 4,6 5,4 8,6 9,4 Table 5 Stripping lengths cable group B A B min. mm max. mm min. mm m
30、ax. mm 3,6 4,4 7,6 8,4 For stripping, see EN 2812. BS EN 4652-210:2015EN 4652-210:2015 (E) 8 5 Test methods See Table 6. Table 6 Test methods EN 2591- Designation of the test Details 101 Visual examination Applicable 102 Examination of dimensions and mass TNC interface style A: see subclause 4.1 and
31、 EN 4652-001. TNC interface style B: see subclause 4.1 and EN 4652-001. TNC interface style C: see subclause 4.1 and EN 4652-001. The manufacturer shall precise which style of interface is used. 201 Contact resistance - low level Applicable on centre contact 202 Contact resistance at rated current 1
32、,5 m max. = initial centre contact, and 2,0 m max. after test For nickel plated connectors: 0,4 m max. = initial external contact, and 1,2 m max. after test 204 Discontinuity of contacts in the microsecond range Duration of micro discontinuity: 1 s Method B Test time: throughout duration of tests EN
33、 2591-402 and EN 2591-403 206 Measurement of insulation resistance 5 000 M min. 207 Voltage proof test Method A Pressure Mated aUnmated aSea level 1 500 1 500 12,1 kPa 800 550 4,7 kPa 375 350 2,7 kPa 250 200 aValues in Volts RMS. 212 Surface transfer impedance Applicable (up to 100 MHz) 3 m 1 MHz 1
34、m 10 MHz 3 m 30 MHz 5 m 100 MHz BS EN 4652-210:2015EN 4652-210:2015 (E) 9 EN 2591- Designation of the test Details 214 Lightning strike, current and voltage pulse 10 kA wave form 5 A, 10 A RMS 221 Voltage Standing Wave Ratio (VSWR) Method B VSWR 1,15 up to 6 GHz 222 Insertion Loss (I.L.) 0,04f dB ma
35、x., f in GHz Measurement shall be performed with connector mated with EN 4652-212 or EN 4652-213 receptacle from same technology and cable group. 223 Measurement of characteristic impedance of a coaxial connector or contact 50 5 at 200 MHz Input impedance 224 RF leakage Measured from 2 GHz to 3 GHz
36、50 dB for connectors on cable group A 60 dB for connectors on cable group B 225 RF high potential withstanding voltage 1 000 V at 5 MHz 226 Corona level Corona extinction voltage 315 V rms at 4,4 kPa (70000 feet altitude) 303 Cold/low pressure and damp heat Five (5) cycles Minimum temperature 60 C 3
37、05 Rapid change of temperature Mated connectors TA= +05165 C; TB= 5065 C. 307 Salt mist The connectors shall be suspended in the test chamber with non-metallic cords, so that no accumulation of condensed saline solution can occur. The connectors shall be: subjected to 50 cycles of mating and unmatin
38、g at a rate 5 cycles/min.; exposed to the salt mist: mated for 240 h. Not exposed to the salt mist: unmated for 48 h. BS EN 4652-210:2015EN 4652-210:2015 (E) 10 EN 2591- Designation of the test Details 308 Sand and dust The mated connectors shall be arranged so that their longitudinal axis is parall
39、el to the wind direction, with the rear of the plug facing the wind. Wind velocity in the duct: (3,5 0,5) m/s Number of cycles: one (1) 311 Low air pressure Refer to test EN 2591-207. 314 Immersion at low air pressure Specimen without heat shrinkable tube. In unmated condition (applicable only for c
40、onnectors on cable group A). After the three (3) cycles, remove the specimen from salt water, clean the interface with soft paper. In mated condition (applicable for all connectors): standard procedure. 315 Fluid resistance See EN 4652-001. 317 Flammability Method A 402 Shock Method A, half sine Sev
41、erity 30 g, duration 11 ms Number of shocks: one (1) in each way for each of the three (3) axis (six (6) shocks in all) 403 Sinusoidal and random vibration Method A: sinusoidal vibration with the following individual modalities: Level 2 50 Hz to 70 Hz 1,5 mm double amplitude 70 Hz to 2 000 Hz 20 g T
42、hree (3) axis or two (2) axis (straight connectors) Duration 4 h per axis at ambient temperature 404 Transverse load Applicable on rear of plug; torque moment = 15 Nm 406 Mechanical endurance 500 cycles 408 Mating and unmating forces 0,23 Nm max. 409 Contact retention in insert 27 N min., applicable
43、 on cabled specimen 417 Tensile strength (crimped connection) See Table 2. 418 Gauge insertion/extraction forces (female contacts) Not applicable 422 Locking wire hole strength Applicable 507 Plating porosity Applicable BS EN 4652-210:2015EN 4652-210:2015 (E) 11 EN 2591- Designation of the test Deta
44、ils 508 Measurement of thickness of coating on contacts Applicable 509 Adhesion of coating on contacts Applicable 513 Magnetic permeability 2 6 Qualification Qualification test programme: see EN 4652-001. BS EN 4652-210:2015EN 4652-210:2015 (E) 12 7 Quality assurance See EN 9133. 8 Designation EXAMP
45、LE Description block CONNECTOR, COAXIAL Identity block EN4652-210A50 Number of the basic standard Connector interface type code (see EN 4652-001) 2 = TNC Technology of assembly code (see EN 4652-001) 1 = clamp Connector model code (see EN 4652-001) 0 = straight plug Cable group code (see Table 3) Im
46、pedance: 50 = 50 NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. 9 Marking See EN 4652-001. 10 Packaging See EN 4652-001. 11 Storage See EN 4652-001. BS EN 4652-210:2015This page deliberately left blankBSI is the national body responsible for p
47、reparing British Standards and other standards-related publications, information and services.BSI is incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)BSI Group Headquarters389 Chiswick High R
48、oad London W4 4AL UKAbout usWe bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined thro
49、ugh our open consultation process. Organizations of all sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Standards by visiting our website at or contacting our Customer Services team or Knowledge Centre.Buying standardsYou ca