BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf

上传人:terrorscript155 文档编号:552159 上传时间:2018-12-09 格式:PDF 页数:22 大小:660.37KB
下载 相关 举报
BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf_第1页
第1页 / 共22页
BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf_第2页
第2页 / 共22页
BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf_第3页
第3页 / 共22页
BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf_第4页
第4页 / 共22页
BS EN 673-2011 Glass in building Determination of thermal transmittance (U value) Calculation method《建筑玻璃 热传递系数(U值)的测定 计算方法》.pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 673:2011Glass in building Determination of thermal transmittance (U value) Calculation methodBS EN 673:2011 BRITISH STANDARDNational forewordThis British Standard is the UK

2、 implementation of EN 673:2011. It supersedes BS EN 673:1998, which is withdrawn.The UK participation in its preparation was entrusted to T e c h n i c a l C o m m i t t e e B / 5 2 0 / 4 , P r o p e r t i e s a n d g l a z i n g m e t h o d s .A list of organizations represented on this committee c

3、an be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 71226 5 ICS 81.040.20 Compliance with a British Standard cannot confer immunity from legal ob

4、ligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2011.Amendments issued since publicationDate T e x t a f f e c t e dBS EN 673:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 673 February 2011 ICS 81.040.20 Supersedes

5、 EN 673:1997English Version Glass in building - Determination of thermal transmittance (U value) - Calculation method Verre dans la construction - Dtermination du coefficient de transmission thermique, U - Mthode de calcul Glas im Bauwesen - Bestimmung des U-Werts (Wrmedurchgangskoeffizient) - Berec

6、hnungsverfahren This European Standard was approved by CEN on 2 January 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibl

7、iographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respon

8、sibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Gre

9、ece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Managem

10、ent Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 673:2011: EBS EN 673:2011EN 673:2011 (E) 2 Contents Page Foreword 3Introduction .41 Scope 42 Normative references 53 Terms and defin

11、itions .54 Symbols, dimensionless numbers and subscripts 54.1 Symbols 54.2 Dimensionless Numbers .64.3 Subscripts 65 Basic formulae .75.1 General 75.2 U value 75.3 Radiation conductance hr.85.4Gas conductance hg85.4.1 General 85.4.2 Vertical glazing .95.4.3 Horizontal and angled glazing 96 Basic mat

12、erial properties 96.1 Emissivity .96.2 Gas properties . 106.3 Infrared absorption of the gas . 127 External and internal heat transfer coefficients 127.1 External heat transfer coefficient he. 127.2 Internal heat transfer coefficient hi. 127.3 Design values 138 Declared values: standardized boundary

13、 conditions . 139 Expression of the results . 149.1 U values . 149.2 Intermediate values 1410 Test report . 1410.1 Information included in the test report . 1410.2 Identification of the glazing . 1410.3 Cross section of the glazing 1510.4 Results . 15Annex A (normative) Iteration procedure for glazi

14、ng with more than one gas space 16Bibliography . 18BS EN 673:2011EN 673:2011 (E) 3 Foreword This document (EN 673:2011) has been prepared by Technical Committee CEN/TC 129 “Glass in building”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national sta

15、ndard, either by publication of an identical text or by endorsement, at the latest by August 2011, and conflicting national standards shall be withdrawn at the latest by August 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.

16、 CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 673:1997. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements

17、of EU Directive(s). According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hunga

18、ry, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 673:2011EN 673:2011 (E) 4 Introduction CEN/TC 129/WG9 “Light and energy transmission, thermal insulation“ prepar

19、ed a working draft based on the document ISO/DIS 10292, “Thermal insulation of glazing: Calculation rules for determining the steady state U value of double or multiple glazing“, document that was prepared by ISO/TC 160, “Glass in building“. This was published in 1997 as EN 673. This edition is a re

20、vision of EN 673:1997. The main change in this edition is that the internal and external heat transfer coefficients have been amended slightly to avoid any ambiguities. The original annex on the determination of emissivity has been removed and reference is made to EN 12898. Other changes include the

21、 incorporation of amendments A1 and A2 to EN 673:1997 and general improvements to the text to aid understanding. 1 Scope This European Standard specifies a calculation method to determine the thermal transmittance of glazing with flat and parallel surfaces. This European Standard applies to uncoated

22、 glass (including glass with structured surfaces, e.g. patterned glass), coated glass and materials not transparent in the far infrared which is the case for soda lime glass products, borosilicate glass and glass ceramic. It applies also to multiple glazing comprising such glasses and/or materials.

23、It does not apply to multiple glazing which include in the gas space sheets or foils that are far infrared transparent. The procedure specified in this European Standard determines the U value1) (thermal transmittance) in the central area of glazing. The edge effects due to the thermal bridge throug

24、h the spacer of a sealed glazing unit or through the window frame are not included. Furthermore, energy transfer due to solar radiation is not taken into account. The effects of Georgian and other bars are excluded from the scope of this European Standard. The standard for the calculation of the ove

25、rall U value of windows, doors and shutters (see EN ISO 10077-1 1) gives normative reference to the U value calculated for the glazing components according to this standard. For the purpose of product comparison, a vertical position of the glazing is specified. In addition, U values are calculated u

26、sing the same procedure for other purposes, in particular for predicting: heat loss through glazing; conduction heat gains in summer; condensation on glazing surfaces; the effect of the absorbed solar radiation in determining the solar factor (see Bibliography, 2). Reference should be made to 3, 4 a

27、nd 5 or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard. A procedure for the determination of emissivity is given in EN 12898. 1) In some countries the symbol k has been used hitherto. BS EN 673:2011EN 673:2011 (E) 5 Th

28、e rules have been made as simple as possible consistent with accuracy. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced

29、document (including any amendments) applies. EN 674, Glass in building Determination of thermal transmittance (U value) Guarded hot plate method EN 675, Glass in building Determination of thermal transmittance (U value) Heat flow meter method EN 12898, Glass in building Determination of the emissivi

30、ty 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 U value parameter of glazing which characterizes the heat transfer through the central part of the glazing, i.e. without edge effects, and states the steady-state density of heat transfer rat

31、e per temperature difference between the environmental temperatures on each side NOTE The U value is given in watts per square metre Kelvin W/(m2K). 3.2 declared value U value obtained under standardized boundary conditions (see Clause 8) 4 Symbols, dimensionless numbers and subscripts 4.1 Symbols A

32、 constant - c specific heat capacity of gas J/(kgK) d thickness of material layer (glass or alternative glazing material) m F volume fraction - h - heat transfer coefficient W/(m2K) - also thermal conductance W/(m2K) M number of material layers - n exponent - N number of spaces - BS EN 673:2011EN 67

33、3:2011 (E) 6 r thermal resistivity of glass (glazing material) mK/W P gas property - s width of gas space m T absolute temperature K U thermal transmittance W/(m2K) temperature difference K corrected emissivity - nnormal emissivity (perpendicular to the surface) - gas density kg/m3Stefan-Boltzmanns

34、constant 5,67 x 10-8W/(m2K4) dynamic viscosity of gas kg/(ms) - thermal conductivity of gas in space W/(mK) temperature on the Celsius scale C 4.2 Dimensionless Numbers Gr Grashof number - Nu Nuselt number - Pr Prandtl number - 4.3 Subscripts c convection e external i internal j jthmaterial layer k

35、kthspace g gas m mean n normal r radiation s space BS EN 673:2011EN 673:2011 (E) 7 t total 1;2 first, second etc. 5 Basic formulae 5.1 General The method of this standard is based on a calculation according to the following principles. 5.2 U value The U value is given by: 1U=1he+1ht+1hi(1) where hea

36、nd hiare the external and internal heat transfer coefficients; htis the total thermal conductance of the glazing. 1ht=1hs1N+ dj1M rj(2) where hsis the thermal conductance of each gas space; N is the number of spaces; djis the thickness of each material layer; rjis the thermal resistivity of each mat

37、erial (thermal resistivity of soda lime glass = 1,0 mK/W); M is the number of material layers. hs,k= hr,k+ hg,k(3) where hs,kis the heat transfer of the kthspace; hr,k is the radiation conductance; hg,kis the U value of gas. NOTE The thermal resistivity of components other than glass (e.g. interlaye

38、rs in laminated glass) may be taken into account in determining the U value. For the purpose of this standard, thermal conductivity values used for glass in building should be obtained from the table of generally accepted values in the relevant product standard (e.g. EN 572-1 for basic soda lime sil

39、icate glass). In instances where the effects are not considered significant or important, a simplified approach may be taken, i.e. ignoring the effects of components other than glass. BS EN 673:2011EN 673:2011 (E) 8 5.3 Radiation conductance hrThe radiation conductance is given by: 3km,1k,2k,1r1114

40、Th+= (4) where is the Stefan-Boltzmanns constant; Tm,kis the mean absolute temperature of the gas space; 1,k and 2,k are the corrected emissivities of the surfaces bounding the enclosed space between the panes at Tm,k. 5.4 Gas conductance hg 5.4.1 General The gas conductance is given by: kkk,gshNu=

41、(5) where skis the width of the kthspace; k is the thermal conductivity of the kthgas; Nu is the Nusselt number. Nu = A (Gr Pr)n(6) where A is a constant; Gr is the Grashof number; Pr is the Prandtl number; n is an exponent. Gr =9,81 s3 T 2Tm2(7) Pr =c(8) BS EN 673:2011EN 673:2011 (E) 9 where T is t

42、he temperature difference between glass surfaces bounding the gas space; is the density; is the dynamic viscosity; c is the specific heat capacity; Tmis the mean temperature. The Nusselt number is calculated from Equation (6). If Nu is less than 1, then the value unity is used for Nu in Equation (5)

43、. 5.4.2 Vertical glazing For vertical glazing: A is 0,035 n is 0,38 5.4.3 Horizontal and angled glazing For horizontal or angled glazing and upward heat flow the heat transfer by convection is enhanced. This effect shall be considered by substituting the following values of A and n in Equation (6).

44、Horizontal spaces A = 0,16 n = 0,28 Space at 45 A = 0,10 n = 0,31 For intermediate angles linear interpolation is satisfactory; however, the linear interpolation shall be between the two nearest points. When the direction of heat flow is downward the convection shall be considered suppressed for pra

45、ctical cases and Nu = 1 is substituted in Equation (5). 6 Basic material properties 6.1 Emissivity The corrected emissivities of the surfaces bounding the enclosed spaces are required to calculate the radiation conductance hrin Equation (4). For uncoated soda lime glass surfaces or for soda lime gla

46、ss surfaces with coatings which have no effect on the emissivity, the corrected emissivity to be used is 0,837. NOTE 1 With reasonable confidence the same value may be used for uncoated borosilicate glass. For other coated surfaces the normal emissivity nshall be determined with an infrared spectrom

47、eter in accordance with EN 12898. The corrected emissivity shall be determined from the normal emissivity in accordance with EN 12898. BS EN 673:2011EN 673:2011 (E) 10 NOTE 2 Two different definitions of emissivity should be theoretically used to describe radiation exchange between: a) glass surface

48、s facing each other in glazing; b) a glass surface facing a room. However, in practice numerical differences are found to be negligibly small. Thus corrected emissivity describes both types of heat exchange with a sufficient approximation. NOTE 3 For laminated glass and laminated safety glass where

49、a low emissivity coating is in direct contact with an interlayer, the effect of the low emissivity coating is negated, in terms of U value. 6.2 Gas properties The properties of the gas filling the space are required. These are: thermal conductivity density dynamic viscosity specific heat capacity c The relev