1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 12045:2000 The Euro
2、pean Standard EN 12045:2000 has the status of a British Standard ICS 91.060.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Shutters and blinds power operated Safety in use Measurement of the transmitted forceThis British Standard, having been prepared under the direction o
3、f the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 August 2000 BSI 08-2000 ISBN 0 580 34027 9 BS EN 12045:2000 Amendments issued since publication Amd. No. Date Comments National foreword This British St
4、andard is the official English language version of EN 12045:2000. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/3, Domestic shutters and blinds, which has the responsibility to: aid en
5、quirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented o
6、n this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence I
7、ndex”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself
8、 confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.(8523($167$1
9、$5 1250(8523e(11( (8523b,6 - the movement occurring in the course of travel can be controlled by the user activating the control device (stopping, starting, reversing).Page 4 EN 12045:2000 %6, 3.4 automatic operation powered operation when the control device is such that one of the movements is outs
10、ide the control of the user (setting in motion extension or retraction, or stopping, starting or reversing) NOTE An automatic operation relating to extension, whereby, e.g., when setting in motion, the user cannot stop the movement during the travel. The operation can be automatic for the whole cycl
11、e. In this case, there is no possibility for the user to stop the movement in either direction, once the operation has been commenced. 3.5 transmitted force the static force (F) exercised by the edge of the curtain, the bottom rail or front profile on a fixed obstacle during extension. Figures 1 to
12、4 illustrate directions of the transmitted forces 3.6 shutter with accumulating or retractable laths shutter for which the transmitted force against an obstacle results due to the progressive accumulation of the weight of the slats 3.7 accumulation condition the curtain being placed at 0,16 m from i
13、ts fully extended position, a static force of 150 N applied to the bottom of the curtain in the direction of retraction shall cause a minimum displacement of 0,04 m 3.8 crushing area area likely to occur in the last 0,40 m travel of the curtain, when the transmitted force is 150 N. In the case of aw
14、nings which project, the crushing zone exists if, the awning being in the fully extended position, a fixed obstacle is located less than 0,40 m from the front profile, this being situated at less than 1,80 m head height (see Figures 1 to 4) ) P %RWWRP UDLO P ) P ) Figure 1 Crushing area Direction of
15、 transmitted force Roller shutter Figure 2 Crushing area Direction of transmitted force Sliding panel shutter (1 or 2 leaves)Page 5 EN 12045:2000 %6, P P Figure 3 Crushing area Direction of the transmitted force Wing shutter = P G P ) ) 1 Figure 4 Crushing area Direction of transmitted force Folding
16、 arms awning 3.9 shearing area (Case of conservatory awning) area likely to occur over each fixed idling roller, by the passage of the front profile, assuming the following conditions exist simultaneously: The transmitted force of the front profile exceeds or is equal to 150 N; The front profile is
17、lower than 1,80 m, head height; The distance between the front profile and the fixed roller or any associated fixed obstacle, is 0,07 m. See Figure 5. Figure 5 Conservatory awning Shearing area above each roller created by the passage of the front profile )URQWSURILOH 5ROOHU H = = HP DQG ) 1 DQG =P
18、6KHDULQJDUHD )Page 6 EN 12045:2000 %6, 4 Measurement of transmitted force 4.1 Shutters with accumulating or retractable laths Verification of the accumulation condition Test aim: to measure - the speed of extension of curtain, in the last 0,40 m; - the displacement of the bottom rail in the directio
19、n of retraction under the action of a static force of 150 N. Dimensions: the test is carried out for a height and width of product given by the manufacturer. If the accumulating condition occurs, it will be satisfied for all greater heights and smaller widths. Test preparation: the product is provid
20、ed for the test in a rigid frame and mounted according to the installation instructions of the manufacturer. It is presented vertically and extended up to a distance of 0,16 m from the fully extended position. Test: a load of 150 N shall be applied to the middle of the bottom rail or at mid-height o
21、f the leading edge of the curtain in the direction of retraction. The displacement obtained shall be recorded. The average speed of extension of the curtain shall be measured in the last 0,40 m. Figure 6 illustrates an example of a test device in the case of a roller shutter. P / G P 1 1 Figure 6 Ac
22、cumulating test for the laths Roller shutter 4.2 Roller, sliding shutters, external venetian blinds, flatclosing concertina shutters Test aim: measurement of the transmitted force, when the accumulating condition is not satisfied. Dimensions: for a given motor, the test is carried out for the minimu
23、m dimensions specified by the manufacturer. Test preparation: the product is provided for the test in a rigid frame and mounted according to the installation instructions of the manufacturer. It is presented vertically so that the travel of the curtain is limited to 0,40 m (first measurement) and to
24、 0,10 m (second measurement) from its full extension (see Figures 1 and 2).Page 7 EN 12045:2000 %6, Test: a force measuring device, dynamometer or other, accurate to 3 % is placed at the middle of the bottom rail (in the case of roller shutters or venetian blind) or at a mid-height of the leading ed
25、ge (in case of sliding panel shutters or flat closing concertina shutter) in the direction of retraction. The curtain being operated in the direction of extension, the effort required to immobilize the curtain in recorded. The transmitted force is the highest value of the two measurements recorded.
26、4.3 Wing shutters Test aim: measurement of the transmitted force and the amount of distance between the leaves out of phase (see Figure 3). Dimensions: for a given motor, the test is carried out for the minimum dimensions specified by the manufacturer. Test: the test is carried out as described in 4
27、.2 (force measurement device placed at the middle of the edge of the “closing” leaf and measurements at 0,40 m and then 0,10 m of the full extension position). Furthermore, it is verified, when the “closing” leaf is at 0,40 m of the fully extension position, the previous leaf has a minimum gap of 0,
28、10 m, the measurement being between edges of leaves (see Figure 3). 4.4 Projection awnings, guided blinds and conservatory awnings Test aim: measurement of transmitted force at the extended position. Dimensions: the test is carried out at the minimum dimensions specified by the manufacturer: for fol
29、ding and trellis arm awnings, for each type of arm, for other awnings and blinds, for the heaviest front profile. Test preparation: the awning or blind provided on a rigid frame and mounted according to the manufacturers installation instructions and extended until the front profile is situated 0,40
30、 m (first measurement) and to 0,10 m (second measurement) from the fully extended position, arms in the horizontal position in the case of pivot arm awning. Test: a dynamometer, accurate to 3 %, is located at the middle of the front profile parallel to the side edge of the fabric and at right angles
31、 to the front profile or roller tube. The awning or blind is extended, the force necessary to maintain the front profile in a stationary position shall be recorded. The transmitted force is the highest value of the two measurements recorded. 4.5 Conservatory awnings Test aim: measurement of the transmitted force at each idling roller and the distance between these and the front profile. Dimensions: the test is carried out with the heaviest front profile at the minimum size of the product as specified by the manufacturer.