1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58liners Part 2: Requirements and test methods under wet conditionsThe European Standard EN 13063-2:2
2、005, incorporating amendment A1:2007, has the status of a British StandardICS 91.060.40Chimneys System chimneys with clay/ceramic flue BRITISH STANDARDBS EN 13063-2:2005Incorporating amendment no. 1BS EN 13063-2:2005This British Standard was published under the authority of the Standards Policy and
3、Strategy Committee on 5 December 2005 BSI 2007ISBN 978 0 580 60209 2Amendments issued since publicationAmd. No. Date Comments17365 28 September 2007 Implementation of CEN amendment A1:2007This publication does not purport to include all the necessary provisions of a contract. Users are responsible f
4、or its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard is the UK implementation of EN 13063-2:2005, incorporating amendment A1:2007.The UK participation in its preparation was entrusted by Technical Committee
5、 B/506, Chimneys, to Subcommittee B/506/3, Chimneys and their components having inner linings of clay or ceramic.A list of organizations represented on this subcommittee can be obtained on request to its secretary.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13063-2:2005+A1 July 2007 ICS 91.
6、060.40 Supersedes EN 13063-2:2005 English Version Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditions Conduits de chemines - Conduits de chemines rsistant aux feux de chemines paroi intrieure en terre cuite/cramique - Partie 2: Exigen
7、ces et mthodes dessai en conditions humides Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 2: Anforderungen und Prfungen fr feuchte Betriebsweise This European Standard was approved by CEN on 1 April 2005 and includes Amendment 1 approved by CEN on 14 June 2007. CEN members are bo
8、und to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
9、CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same st
10、atus as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roman
11、ia, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reserved
12、 worldwide for CEN national Members. Ref. No. EN 13063-2:2005+A1:2007: EEN 13063-2:2005+A1:2007 (E) 2 Contents Page Foreword .3 1 Scope 4 2 Normative references5 3 Terms and definitions .5 4 Shapes, dimensions and tolerances .7 5 Material requirements .7 6 Replacement of single components of the sys
13、tem chimney12 7 Designation 13 8 Product information 14 9 Marking and labelling15 10 Evaluation of conformity 15 Annex A (normative) Test methods.18 Annex B (informative) Thermal resistance .27 Annex C (normative) Sampling procedures for an AQL of 10 % and inspection level S2 .28 Annex ZA (informati
14、ve) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive .32 Bibliography39 EN 13063-2:2005+A1:2007 (E) 3 Foreword This document (EN 13063-2:2005+A1:2007) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held
15、 by UNI. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008 and conflicting national standards shall be withdrawn at the latest by April 2009. This document includes Amendment 1 approved by CEN o
16、n 2007-06-14. This document supersedes EN 13063-2:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! “. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports
17、essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document is part 2 of a series of standards for system chimneys with clay/ceramic flue liners. Part 1 is for chimneys with sootfire resistance
18、and part 3 is for system air flue chimneys. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany
19、, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 13063-2:2005+A1:2007 (E) 4 1 Scope This European Standard specifies the requirements and test method
20、s for multiwall system chimneys working under wet conditions (in the following expressed as “wet chimney”) with pressure type N1, N2 or P1 according to EN 1443 and a working temperature below or equal T600 according to !EN 13063-1:2005+A1“, in which the products of combustion are conveyed to the atm
21、osphere through clay/ceramic flue liners. Marking and inspection are also covered by this document. This European Standard does not apply to structurally independent (free standing or self-supporting) system chimneys. The wet chimney may comprise the following appropriate components: clay/ceramic fl
22、ue liners; insulation layer; outer walls; acid resistant mortar for jointing flue liners or elastomeric sealant; mortar for jointing outer walls; terminal; chimney base; condensate collector; condensate outlet; cladding; opening section; cleaning and inspection door; distance piece; reinforcement. T
23、he wet system chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole system chimney. NOTE This document does not cover soot fire resistance chimneys. EN 13063-2:2005+A1:2007 (E) 5 2 Normative refere
24、nces The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 998-2:2003,!Specification for mortar for
25、masonry Part 2: Masonry mortar“ EN 1366-8,!Fire resistance tests for service installations Part 8: Smoke extraction ducts“ EN 1443:2003, Chimneys General requirements EN 1457:1999, Chimneys Clay/ceramic flue liners Requirements and test methods EN 12446:2003, Chimneys Components Concrete outer wall
26、elements !EN 13063-1:2005+A1:2007“, Chimneys System chimneys with clay/ceramic flue liners Part 1: Requirements and test methods for sootfire resistance !EN 13069:2005“, Chimneys Clay/ceramic outer walls for system chimneys Requirements and test methods EN 13162:2001, Thermal insulation products for
27、 buildings Factory made mineral wool (MW) products Specification EN 13216-1:2004, Chimneys - Test methods for system chimneys Part 1: General test methods EN 13384-1, Chimneys Thermal and fluid dynamic calculation methods Part 1: Chimneys serving one appliance !EN 14241-1“, Chimneys Elastomeric seal
28、s and elastomeric sealants Material requirements and test methods - Part 1: Seals in flue liners EN 14297:2004, Chimneys Freeze-thaw resistance test method for chimney products !ISO 2859-1, Sampling procedures for inspection by attributes Part 1: Sampling schemes indexed by acceptance quality limit
29、(AQL) for lot-by-lot inspection“ 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1443:2003, EN 13216-1:2004, !EN 13063-1:2005+A1:2007“ and the following apply. 3.1 system chimney under wet conditions system chimney is a multiwall construction
30、, consisting mainly of an outer wall, an insulation layer and the inner clay/ceramic flue liner that can work under wet conditions (see Figure 1) EN 13063-2:2005+A1:2007 (E) 6 Key 1 flue liner 2 insulation layer 3 outer wall 4 back ventilation 5 cavities for structural reinforcement 6 non ventilated
31、 air gap Figure 1 Examples of construction of a chimney for wet conditions 3.2 wet operating conditions conditions when the chimney is designed to operate normally with the temperature of the inner surface of the flue liner at and below the water dew point 3.3 condensate collector flue liner base un
32、it for collecting the condensates with an opening for discharging the condensates 3.4 condensate outlet drain to ensure the discharge of the condensates from the condensates collector 3.5 jointing materials for flue liners 3.5.1 prefabricated elastomeric seals prefabricated element made of elastomer
33、ic material, which ensures a gastight seal in a joint EN 13063-2:2005+A1:2007 (E) 7 3.5.2 on site applied elastomeric sealant sealing material which is applied on site to ensure the gas tightness 3.5.3 acid resistant mortar jointing material made with acid resistant mortar 4 Shapes, dimensions and t
34、olerances 4.1 Flue liners 4.1.1 General Flue liners shall meet the requirements on size and tolerance of dimensions given in EN 1457:1999, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6 and 7.7. 4.1.2 External diameter of flue liner When tested in accordance with A.2.6, the external diameter of circular flue liners m
35、easured on any diameter shall not deviate more than 3 % of the manufacturers stated nominal external diameter. 4.2 Insulation The insulation layer shall meet the requirements on tolerances of dimension given in EN 13162:2001, 4.2.2 (length and width) and 4.2.3 (thickness class T3). 4.3 Outer wall el
36、ements Outer wall elements shall fulfil the requirements on shapes and tolerances on dimensions given in: concrete outer wall elements: EN 12446:2003, Clause 7; clay/ceramic outer walls: !EN 13069:2005“, Clause 6; metal outer walls: !EN 13063-1:2005+A1:2007“, Annex B. 4.4 Cleaning and inspection doo
37、rs Dimensions and tolerances shall be declared by the manufacturers. 5 Material requirements 5.1 General requirements for components 5.1.1 Flue liners Flue liners shall meet the requirements of EN 14571999, 8.1, 9.1, 9.2, Clauses 10, 11, 12 and 13. If the requirement of EN 1457:1999, 13.1 “Water vap
38、our permeability“ is not fulfilled, the flue liner may be used for wet chimneys, if the system test for system chimneys under wet conditions according to !EN 13216-1:2004, 5.6, is passed according to the requirements in 5.3.2.1.“ EN 13063-2:2005+A1:2007 (E) 8 5.1.2 Maximum load for opening sections
39、When tested as described in A.2.3, components shall withstand a load (F) of at least five times the manufacturers declared design load (H G). 100GHF=(1) where F is the minimum load, expressed in kilonewton (kN); is the safety factor equal to 5; H is the height of the chimney, is expressed in meter (
40、m); G is expressed in kilogram per meter (kg/m). NOTE The limiting factor of the maximum height of system chimneys is the compressive strength of the opening section. 5.1.3 Jointing material for flue liners 5.1.3.1 Acid resistant mortar 5.1.3.1.1 Density The density of jointing material shall not va
41、ry more than 10 % of the manufacturers declared value when tested in accordance with A.2.2.2. 5.1.3.1.2 Compressive strength The compressive strength shall be tested after a 24 h preconditioning under water in accordance with A.2.2.3.The compressive strength shall be at least 10 N/mm. 5.1.3.1.3 Wate
42、r resistance Acid resistant mortar for jointing the components in system chimneys stated for use in wet conditions shall be tested in accordance with A.2.2.4 and the mass loss from any sample shall not exceed 3 %. 5.1.3.1.4 Acid resistance When tested in accordance with A.2.2.5, the mass loss from a
43、ny sample shall not exceed 2 %. 5.1.3.2 Prefabricated elastomeric seals The elastomeric seals shall comply with !EN 14241-1“. 5.1.4 Insulation 5.1.4.1 General The insulation shall be to the manufacturers specifications and shall be prefabricated and have an independent, permanent shape before and af
44、ter being exposed to heat (e.g. blocks or bonded loose material). EN 13063-2:2005+A1:2007 (E) 9 5.1.4.2 Durability under normal operating conditions When tested in accordance with A.2.1 at test temperature related to the temperature class (see Table 1), the change in the outside surface temperature
45、of the test sample after the fourth cycle of heating shall not exceed 10 % of the maximum outside surface temperature of the sample of the first cycle. Table 1 Test temperatures Temperature class T 80 T 100 T 120 T 140 T 160 T 200 T 250 T 300 T 400 T 450 T 600 Test temperature (C) 100 120 150 170 19
46、0 250 300 350 500 550 700 5.1.5 Outer wall elements Outer wall elements shall fulfil EN 12446 for concrete outer wall elements, !EN 13069“ for clay/ceramic outer wall or Annex B of !EN 13063-1:2005+A1:2007“ for metal outer walls. 5.1.6 Jointing material for outer wall elements Jointing materials use
47、d for jointing outer walls according to EN 12446 for concrete outer wall elements and !EN 13069“ for clay/ceramic outer walls, where supplied with the system chimney, shall comply with the system chimney manufacturers declared specification and shall be at least M2,5 according to EN 998-2:2003, 5.3.
48、1, Table 1. 5.1.7 Wind load The freestanding part of the chimney above the last lateral support of the system chimney shall withstand a wind load of 1,5 kN/m2. The maximum permissible height of a chimney outside the building of a system chimney shall be calculated according to calculation methods ap
49、plicable in the place of use of the chimney, taking into account the tilt momentum of the outer wall element. Alternatively the tilt momentum of the complete construction can be taken into account. A test method to evaluate the tilt momentum is given in A.2.4. 5.2 Safety in use 5.2.1 Thermal shock resistance The wet chimney shall be tested at the normal operating conditions in accordance with the heat stress test method described in !