1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 13352:2012Specification for the performance of automatic tank contents gaugesBS EN 13352:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementatio
2、n of EN 13352:2012. It supersedes BS EN 13352:2002, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee PVE/393/5, Tank contents gauges for petroleum liquids.A list of organizations represented on this committee can be obtained on request to its secretary.
3、This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 71515 0 ICS 23.020.10; 75.180.30 Compliance with a British Standard
4、cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2012.Amendments issued since publicationDate T e x t a f f e c t e dBS EN 13352:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13
5、352 March 2012 ICS 75.180.30 Supersedes EN 13352:2002English Version Specification for the performance of automatic tank contents gauges Spcification de performance des jauges automatiques de niveau de rservoir Anforderungen an automatische TankfllstandmessgerteThis European Standard was approved by
6、 CEN on 28 January 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national stand
7、ards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and no
8、tified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithua
9、nia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels
10、 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13352:2012: EBS EN 13352:2012EN 13352:2012 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Normative references 63 Terms and definitions .64 General requirements 84.1 Te
11、mperature ranges 84.2 Variations in the properties of stored products .84.3 Humidity 84.4 Characteristics of the materials .95 Performance requirements .95.1 Level measurement .95.2 Temperature measurement .95.3 Water detection 95.4 Essential information . 105.5 Indicator device. 115.6 Manufacturers
12、 instructions . 115.7 Classification and designation 116 Test methods . 126.1 Sampling 126.2 Test sequence . 126.3 Test report . 127 Marking and labelling . 138 Test of provision of essential information . 138.1 Test objective 138.2 Evaluation 138.3 Test equipment . 138.4 Test method . 138.5 Test re
13、sult 149 Test for level and temperature performance . 149.1 Test objective 149.2 Evaluation 149.3 Test equipment . 149.3.1 Test vessel . 149.3.2 Secondary vessel 149.3.3 Reference level measurement device (RLMD) . 149.3.4 Reference temperature measurement devices (RTMD) 149.3.5 Monitoring devices .
14、149.3.6 ATG 159.3.7 Environmental chamber . 159.3.8 Temperature stabilisation 159.4 Test method . 159.4.1 Test schedule 159.4.2 Preparation 169.4.3 Trial run 169.4.4 MPE test A for level 169.4.5 MPE test B for level and temperature . 189.4.6 Repeatability test for level . 19BS EN 13352:2012EN 13352:
15、2012 (E) 3 9.4.7 Test of the temperature category of the indicator device unit . 219.5 Test results and analysis 229.5.1 General . 229.5.2 MPE test A for level . 229.5.3 MPE test B for temperature 239.5.4 MPE test B for level . 249.5.5 Repeatability test for level 249.5.6 Test of the temperature cat
16、egory of the liquid level measurement . 259.5.7 Classification of the ATG 2710 Test for water detection capability 2810.1 Test objective . 2810.2 Evaluation. 2810.3 Test equipment 2810.4 Test . 2810.4.1 Preparation . 2810.4.2 Stabilisation . 2910.4.3 Test procedure . 2910.5 Test results 3011 Environ
17、mental aspects . 30Annex A (informative) Evaluation of conformity. 31A.1 General . 31A.2 Initial type testing 31A.3 Factory production control. 31A.4 Continuous surveillance . 32Annex B (informative) Gauge sensors installation . 33B.1 General . 33B.2 Reference datum points 33B.3 Safety 34B.4 Ingress
18、 protection . 35Annex C (informative) A-deviations 36Annex D (informative) Environmental Aspects 37Annex E (normative) Compatibility with fuels . 39E.1 Compatibility tests for materials 39E.2 Test for parts exposed to fuels vapours . 39E.3 Test for parts in direct contact with fuels . 39Bibliography
19、 41BS EN 13352:2012EN 13352:2012 (E) 4 Foreword This document (EN 13352:2012) has been prepared by Technical Committee CEN/TC 393 “Equipment for storage tanks and for filling stations”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard,
20、either by publication of an identical text or by endorsement, at the latest by September 2012, and conflicting national standards shall be withdrawn at the latest by September 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.
21、CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13352:2002. The main changes with respect to the previous edition are listed below: test liquid changed; requirement concerning the compatibility of the materials in contact wi
22、th fuels (including ethanol blends and biodiesel) and/or their vapour added; test equipment modified; test procedures modified to reduce the number of tests without affect the overall performances; some procedures are performed in climatic chamber; some notes about the performance of water indicatio
23、n added that may be affected if the fuel to monitor is an ethanol blend; information concerning environmental aspects included. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, B
24、elgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom
25、. BS EN 13352:2012EN 13352:2012 (E) 5 Introduction The principal function of a tank gauge is to measure the level of liquid contained in a storage tank without the need to access the tank and take manual dip readings. The gauge measures liquid parameters, which can include height, mass, temperature,
26、 density and pressure. These can then be used to determine the tanks content. Methods of establishing tanks content, e.g. direct volume measurement, are not addressed in this standard. The increasing need for continuous inventory control for security, effective site operation and environmental prote
27、ction has made the use of tank gauges a practical solution for any tank installation. In addition, in the case of volatile products, the advent of vapour emission control makes access to the tank for dipping purposes increasingly difficult. Automatic tank gauging systems are devices which can interf
28、ace with other measuring equipment and can be capable of providing one or more of the following functions: Basic gauging Where the gauge is used solely to confirm that there is sufficient ullage to accept delivery of a quantity of product into the tank or where the gauge is used solely to measure th
29、e liquid contents of the tank. Inventory control Where the tank contents information is used for stock accounting purposes. This can be transferred manually or, where the gauge forms part of an integrated system, automatically. Automatic reconciliation Where the tank contents information is used tog
30、ether with measured additions to and depletions from the storage tanks contents in a defined time period to identify possible discrepancies. Automatic Calibration Where the tank level information in connection with refuel volume is used to calculate tank calibration data. BS EN 13352:2012EN 13352:20
31、12 (E) 6 1 Scope This European Standard specifies the minimum performance requirements for various classes of automatic tank gauges which are limited to static tanks of shop fabricated manufacture both metallic and non metallic, underground and above ground which do not exceed 5 m in height. It is a
32、pplicable to gauges for fuels (products) which are flammable, having a flash point up to but not exceeding 100 C, stored at premises (e.g. filling stations) at which fuel is dispensed for use in vehicles and other forms of transportation. This European Standard applies to gauges suitable for use at
33、ambient tempera-tures and subject to normal operational pressure variations. Gauging of liquefied gases are not covered by this standard. This European Standard relates to the measurement of product level, measurement of product temperature and detection of the presence of free water. The detection
34、of free water may be compromised for Alcohol blended fuels. NOTE 1 This standard is not intended to cover safety functionalities (i.e. overfill prevention, leak detection, etc.). Further Standards apply. NOTE 2 This standard is not intended to cover legal metrology requirements. 2 Normative referenc
35、es The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2
36、28, Automotive fuels Unleaded petrol Requirements and test methods EN 590:2009+A1:2010, Automotive fuels Diesel Requirements and test methods EN 14214, Automotive fuels Fatty acid methyl esters (FAME) for diesel engines Requirements and test methods EN 15376, Automotive fuels Ethanol as a blending c
37、omponent for petrol Requirements and test methods EN 60296, Fluids for electrotechnical applications Unused mineral insulating oils for transformers and switchgear (IEC 60296) EN ISO/IEC 17025:2005, General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005)
38、3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 automatic tank gauge (ATG) device capable, as a minimum, of providing a measurement of the level of liquid contained in a storage tank without the need for manual access into the tank 3
39、.2 ullage product quantity which can safely be delivered into the tank without running the risk of exceeding the maximum safe filling capacity BS EN 13352:2012EN 13352:2012 (E) 7 3.3 gauge sensor device which measures one or more of product level, temperature and free water presence 3.4 gauging syst
40、em combined system of gauge sensor(s) and associated indicator device(s) 3.5 indicator device device which receives and displays the output signals from the gauge sensor(s). It may process that data and display, print or transmit information as required 3.6 maximum permissible error (MPE) extreme va
41、lues of an error permitted by specifications, regulations etc. for a given measuring instrument 3.7 measuring range (MR) distance between the upper and lower limits of measurement over which the performance requirements are satisfied 3.8 readability property of a measuring instrument where the indic
42、ating device is constructed in such a way that its indication may be read without ambiguity 3.9 reference level measurement device (RLMD) certified level measurement device used for verification of the ATGs performance 3.10 reference temperature measurement device (RTMD) certified temperature measur
43、ement device used for verification of the ATGs performance 3.11 repeatability ability of a measuring instrument to provide closely similar indications for repeated applications of the same measurand under the same conditions of measurement (ISO-Publication) Note 1 to entry: These conditions include:
44、 reduction to a minimum of the variations due to the observer; the same measurement procedure; the same observer; the same measuring equipment, used under the same conditions; the same location; repetition over a short period of time. Note 2 to entry: Repeatability can be expressed quantitatively in
45、 terms of the dispersion characteristics of the indications. BS EN 13352:2012EN 13352:2012 (E) 8 3.12 resolution smallest difference between indications of a displaying device that can be meaningfully distinguished (ISO-Publication) Note 1 to entry: For a digital displaying device, this is the chang
46、e in the indication when the least significant digit changes by one step. Note 2 to entry: This concept applies also to a recording device. 3.13 consecutive readings reading taking from the indicator device at intervals of no less than 1 minute, in consideration of the refresh time of the measuremen
47、t and display cycle 4 General requirements 4.1 Temperature ranges The components of an automatic tank gauge shall be designed for operation under atmospheric conditions and rated subdivided into the temperature categories according to Table 1. Table 1 Temperature category Temperature category Temper
48、ature range O 25 C to +55 C P 5 C to +45 C U 5 C to +30 C I +5 C to +40 C NOTE The temperature category are intended to cover Over-ground, Underground, Indoor and Protected environments. 4.2 Variations in the properties of stored products The performance requirements for ATGs according to 5.1 and 5.
49、2 shall be satisfied when using one or more of the following test liquids: Type 1 Diesel according to EN 590:2009+A1:2010; Type 2 Transformer oil according to EN 60296. NOTE 1 The above test liquids have defined ranges of variations in their physical properties. NOTE 2 The above test liquids cover also the characteristics of gasoline and bio-fuels