1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 14116:2012Tanks for transport ofdangerous goods Digitalinterface for productrecognition devices for liquidfuelsCopyright European Committee for Standardization Provided by
2、IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 14116:2012. It supersedes BS EN 14116:2007+A2:2010 which is withdrawn.The UK participati
3、on in its preparation was entrusted to Technical Committee AUE/18, Tanks for the transport of dangerous goods.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Use
4、rs are responsible for its correct application. The British Standards Institution 2012. Published by BSI Standards Limited 2012ISBN 978 0 580 74088 6 ICS 13.300; 23.020.20; 35.240.60; 43.080.10 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was
5、 published under the authority of the Standards Policy and Strategy Committee on 31 October 2012.Amendments issued since publicationDate T e x t a f f e c t e dCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted
6、 without license from IHS-,-,-BS EN 14116:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14116 October 2012 ICS 01.040.01; 13.300; 23.020.20; 35.240.60 Supersedes EN 14116:2007+A2:2010English Version Tanks for transport of dangerous goods - Digital interface for product recognition devices
7、 for liquid fuels Citernes destines au transport de matires dangereuses -Interface numrique du dispositif de reconnaissance de produits ptroliers Tanks fr die Befrderung gefhrlicher Gter - Digitale Schnittstelle fr das Produkterkennungssystem fr flssige Kraft- und Brennstoffe This European Standard
8、was approved by CEN on 1 September 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning suc
9、h national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own
10、 language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, G
11、reece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMU
12、NG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14116:2012: ECopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo repro
13、duction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Normative references 63 Terms, definitions and abbreviations 63.1 Terms and definitions .63.2 Abbreviations .74 Functions 85 Design characteristics 95.1
14、General 95.2 Temperature range . 105.3 Materials of construction . 105.4 PRD 105.5 PID 115.5.1 General specification . 115.5.2 Diode and ESD protection . 125.6 Contact and insulation resistances 135.7 Electrical requirements for hoses . 135.8 System architecture of MultiPID 145.9 Electrical design c
15、haracteristic of MultiPID . 145.9.1 Technical description of MultiPID . 145.9.2 Modulation for the bi-directional communication . 165.9.3 Message timing . 166 Protocol structure . 186.1 Telegram transmission sequences . 186.2 Bit coding 186.3 Byte frame . 196.4 Byte sequence in multibyte variables 1
16、96.5 Telegram 196.6 Message format . 206.6.1 Format of messages #1 to #32 206.6.2 Format of messages #33 to #255 206.7 Message specification 206.7.1 Reserved messages . 206.7.2 Other messages 216.7.3 Message #1: Product description and overfill status (depot/station to truck) . 216.7.4 Message #2 Lo
17、cation and product details (depot/station to truck) . 236.7.5 Message #3 Multi product loading arm (depot to truck) . 246.7.6 Message #4 Tank properties (station to truck) 246.7.7 Message #5 Rack meter information (depot to truck) . 256.7.8 Message #6 Loading information (truck to depot) 266.7.9 Mes
18、sage #7 Delivery information (truck to station) 276.7.10 Message #8 Station information (station to truck) 286.7.11 Message #9 Acknowledge (depot to truck) 296.7.12 Message #10 Return product information (truck to return station) . 296.7.13 Message #32 CRC 16 297 Tests . 297.1 Type test 29Copyright
19、European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 3 7.1.1 General . 297.1.2 PID . 307.1.3 PRD function test 337.1.4 Test results 357.2 Production test 357.2
20、.1 General . 357.2.2 PID static test . 357.2.3 PID function test 357.2.4 PRD function test 357.2.5 Test results 368 Marking . 369 Installation, operating and maintenance recommendations 36Annex A (informative) Manufacturer ID 37Annex B (normative) Calculation algorithm for CRC 16 . 38Annex C (inform
21、ative) A-deviations 39Annex D (normative) Company code 40Bibliography 41Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 4 Foreword This document
22、 (EN 14116:2012) has been prepared by Technical Committee CEN/TC 296 “Tanks for transport of dangerous goods”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the late
23、st by April 2013, and conflicting national standards shall be withdrawn at the latest by April 2013. This document supersedes EN 14116:2007+A2:2010. In comparison with EN 14116:2007+A2:2010, the following significant changes have been made: content of the individual messages and the structure of the
24、 messages was revised. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of
25、 Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Copyright European Committee for Standardization Provided by IHS
26、 under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 5 Introduction Product recognition, the subject of this European Standard, is the digital interface that allows product data and/or other information to be tran
27、sferred between transport tanks and other installations. The European Committee for Standardisation (CEN) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning hose communication methods given in Clause 4. CEN takes no position c
28、oncerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the CEN that he is willing to negotiate licences either free of charge or under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, t
29、he statement of the holder of this patent right is registered with CEN. Information may be obtained from: FMC Technologies F.A. Sening GmbH Regentstrasse 1 D-25474 Ellerbek Germany Phone: +49-4101 304-0 Fax: +49-4101-304-133 / 255 Attention is drawn to the possibility that some of the elements of th
30、is document may be the subject of patent rights other than those identified above. CEN shall not be held responsible for identifying any or all such patent rights. CEN (http:/www.cen.eu/cen/WorkArea/IPR/Pages/default.aspx) and CENELEC (http:/www.cenelec.eu/membersandexperts/toolsandapplications/inde
31、x.html ) maintain on-line lists of patents relevant to their standards. Users are encouraged to consult the lists for the most up to date information concerning patents. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking
32、 permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 6 1 Scope This European Standard covers the digital interface at the product loading and/or discharge coupling which is used for the transfer of product related information and specifies the performance requirements, critical
33、safety aspects and tests to provide compatibility of devices. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the
34、latest edition of the referenced document (including any amendments) applies. EN 13616:2004, Overfill prevention devices for static tanks for liquid petroleum fuels EN 15208, Tanks for transport of dangerous goods Sealed parcel delivery systems Working principles and interface specifications EN 6007
35、9-0, Explosive atmospheres Part 0: Equipment General requirements (IEC 60079-0) EN 60079-11, Explosive atmospheres Part 11: Equipment protection by intrinsic safety “i“ (IEC 60079-11) ISO 2859-1, Sampling procedures for inspection by attributes Part 1: Sampling schemes indexed by acceptance quality
36、limit (AQL) for lot-by-lot inspection ISO 8601, Data elements and interchange formats Information interchange Representation of dates and times 3 Terms, definitions and abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 message
37、 defined data set 3.1.2 telegram frame that contains at least one standardised message 3.1.3 maximum input voltage Uiaccording to EN 60079-11 3.1.4 maximum output voltage U0according to EN 60079-11 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleN
38、o reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 7 3.1.5 maximum input current Iiaccording to EN 60079-11 3.1.6 maximum output current I0according to EN 60079-11 3.1.7 maximum input power Piaccording to EN 60079-11 3.1.8 maximum output power P0acc
39、ording to EN 60079-11 3.1.9 maximum internal capacitance Ciaccording to EN 60079-11 3.1.10 maximum internal inductance Liaccording to EN 60079-11 3.1.11 Multiple Product Identification Device MultiPID electronic device emulating at least one PID, extended by the ability of bi-directional communicati
40、on 3.2 Abbreviations For the purposes of this document, the following abbreviations apply. ASCII American Standard Code for Information Interchange CPDP Comit Professionnel Du Ptrole ESD Electro-Static Discharge LSB Least Significant Bit MSB Most Significant Bit PID Product Identification Device PRD
41、 Product Recognition Device RON Research Octane Number Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 8 4 Functions Whenever a physical connect
42、ion according to Figure 1 or Figure 2 is made, the digital interface enables the transfer of product recognition data to the transport tank. The purpose of this digital interface is to provide the data for the following types of applications: a) automatic product identification for each compartment
43、or tank; b) cross over prevention. Bi-directionality may add the ability of communication between the stationary parts and the tank vehicle, e.g. the transfer of data of measured quantities in both directions. Key 1 pipework of loading arm with insulated coupling 2 pipework of transport tank with in
44、sulated coupling 3 vapour line 4 product line 5 PID, vapour 6 PID, product 7 PRD a required, if only one connection is established Figure 1 Loading Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without lic
45、ense from IHS-,-,-BS EN 14116:2012EN 14116:2012 (E) 9 Key 1 pipework of transport tank with insulated coupling 2 conductive hoses band pipework of stationary tank with insulated couplings 3 vapour line 4 product line 5 PRD 6 PID, product 7 PID, vapour arequired, if only one connection is established
46、 bif the discharge hoses are not conductive then the conductivity of these hoses shall be achieved by other means Figure 2 Unloading PRD supplies an intrinsically safe circuit. 5 Design characteristics 5.1 General The PRD shall be located on the transport tank. The PID shall be connected in series t
47、o a current loop with the PRD. The PRD reads the PID by powering the PID through the hose or loading arm. The PID then sends its data by modulating the supply current, which is sensed by the PRD; see Figure 3. The PID sends its data, using messages, which are numbered from 1 to 255. The PID always transmits “message #1“. By implementing more messages, it is possible to program the PID with other types of information; see 6.6. Since the PID modulates the supply current, PIDs shall not be connected in parallel. Copyright European Committee for Standardization Provided by IHS under license with