1、BRITISH STANDARD BS EN 14317-1:2004 Thermal insulation products for buildings In-situ thermal insulation formed from exfoliated vermiculite (EV) products Part 1: Specification for bonded and loose-fill products before installation The European Standard EN 14317-1:2004 has the status of a British Sta
2、ndard ICS 91.100.60 BS EN 14317-1:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 26 August 2004 BSI 26 August 2004 ISBN 0 580 44341 8 National foreword This British Standard is the official English language version of EN 14317-1:2004. T
3、he UK participation in its preparation was entrusted by Technical Committee B/502, Aggregates, to Subcommittee B/502/5, Lightweight aggregates, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The
4、British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards
5、 Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the resp
6、onsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front co
7、ver, the EN title page, pages 2 to 26, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN143171 August2004
8、ICS91.100.60 Englishversion ThermalinsulationproductsforbuildingsInsituthermal insulationformedfromexfoliatedvermiculite(EV)productsPart 1:Specificationforbondedandloosefillproductsbefore installation ProduitsisolantsthermiquespourlebtimentIsolation thermiqueformeenplacebasedegranulatslgersde vermic
9、uliteexfolie(EV)Partie1:Spcificationde produitslisetenvracavantmiseenoevre WrmedmmstoffefrGebudeAnder VerwendungsstellehergestellteWrmedmmungmit ProduktenausexpandiertemVermiculite(EV)Teil1: SpezifikationfrgebundeneundSchttdmstoffevordem Einbau ThisEuropeanStandardwasapprovedbyCENon10June2004. CENme
10、mbersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENme
11、mber. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,
12、Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION
13、 EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN143171:2004:EEN 14317-1:2004 (E) 2 Contents page Foreword3 1 Scope 4 2 Normative references 4 3 Terms, definitions, symbo
14、ls, units and abbreviated terms.5 3.1 Terms and definitions .5 3.2 Symbols and abbreviations 6 4 Requirements.6 4.1 General6 4.2 For all applications 6 4.3 For specific applications.8 5 Test methods9 5.1 Sampling.9 5.2 Conditioning.9 5.3 Testing 9 6 Designation code.10 7 Evaluation of conformity.10
15、8 Marking and labelling 11 Annex A (normative) Determination of the declared values of thermal conductivity .12 Annex B (normative) Factory production control .14 Annex C (normative) Preparation of the test specimens to measure thermal conductivity.15 Annex D (normative) Special conditions to be use
16、d for the determination of organic content.16 Annex E (normative) Determination of the water repellency of exfoliated vermiculite.17 Annex F (informative) Example of the determination of the declared value of thermal conductivity for a product or product group 19 Annex ZA (informative) Clauses of th
17、is European Standard addressing essential requirements or other provisions of EU Directives .21 Bibliography 26 EN 14317-1:2004 (E) 3 Foreword This document (EN 14317-1:2004) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is h
18、eld by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2005, and conflicting national standards shall be withdrawn at the latest by February 2005. This document has been prepared und
19、er a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directive(s), see informative Annex ZA which is an integral part of this document. This standard consists of two parts. The fir
20、st part, which is the harmonised part satisfying the mandate, the CPD and is the basis for the CE marking, covers the products, which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installed products. This European Standard is one of a s
21、eries for mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose and urea formaldehyde in-situ formed insulation products used in buildings, but this standard may be used in other areas where appropriate. According to the CEN/CENELEC Internal
22、Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherland
23、s, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14317-1:2004 (E) 4 1 Scope This document specifies the requirements for the four types of exfoliated vermiculite products Vermiculite Aggregate (EVA), Coated Vermiculite (EVC), Hydrophobic Vermiculite
24、(EVH) and Premixed Vermiculite (EVM), containing less than 1 % organic material as defined by Annex D for in-situ insulation of roofs, ceilings, walls and floors. This document is a specification for the insulation products before installation. This document describes the product characteristics and
25、 includes procedures for testing, evaluation of conformity, marking and labelling. This document does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be f
26、ound in regulations or non-conflicting standards. This document does not cover factory made insulation products of formed shapes and boards made with exfoliated vermiculite or in-situ products intended to be used for the insulation of building equipment and industrial installations. This document do
27、es not specify performance requirements for airborne sound insulation and for acoustic absorption applications. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated referenc
28、es, the latest edition of the referenced document (including any amendments) applies. EN 932-1, Tests for general properties of aggregates Part 1: Methods for sampling. EN 932-2, Tests for general properties of aggregates Part 2: Methods for reducing laboratory samples. EN 933-1, Tests for geometric
29、al properties of aggregates Part 1: Determination of particle size distribution Sieving method. EN 1097-3, Tests for mechanical and physical properties of aggregates Part 3: Determination of loose bulk density and voids. EN 12667, Thermal performance of building materials and products Determination
30、of thermal resistance by means of guarded hot plate and heat flow meter methods Products of high and medium thermal resistance. EN 13055-1, Lightweight aggregates Lightweight aggregates for concrete, mortar and grout. EN 13055-2, Lightweight aggregates Part 2: Lightweight aggregates for bituminous m
31、ixtures and surface treatments and for unbound and bound applications excluding concrete, mortar and grout. EN 13172:2001, Thermal insulating products Evaluation of conformity. EN 13820, Thermal insulating materials for building applications Determination of organic content. EN 14317-1:2004 (E) 5 3
32、Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 exfoliated vermiculite insulation material which results from expanding or exfoliating a natural micaceous mineral by heating prEN IS
33、O 9229:1997 3.1.2 vermiculite aggregate exfoliated vermiculite with no treatment or surface coating, used either as a loose insulation in the cavities of walls and roofs and loose placement on ceilings, or for site mixing to specified mix proportions with bonding materials when applied as a surface
34、layer 3.1.3 coated vermiculite exfoliated vermiculite which has a coating 3.1.4 hydrophobic vermiculite exfoliated vermiculite which is treated to give specific hydrophobic properties and used where moisture or water repellency is required 3.1.5 premixed vermiculite exfoliated vermiculite premixed w
35、ith binders, which will require the site addition of water or other material, to enable the insulation product to be bonded, both to itself and the surface of the roof, ceiling, wall or floor 3.1.6 settlement decrease of installed insulation thickness with time, expressed as a percentage of the init
36、ial installed thickness (after compaction if prescribed) 3.1.7 level given value which is the upper or lower limit of requirement, where the level is given by the declared value of the characteristic concerned 3.1.8 class combination of two levels of the same property between which the performance s
37、hall fall, where the level is given by the declared value of the characteristic concerned 3.1.9 internal direct measurements measurements carried out by the manufacturer using the method detailed for a requirement 3.1.10 internal indirect measurements measurements carried out by the manufacturer usi
38、ng the manufacturers own test method EN 14317-1:2004 (E) 6 3.1.11 external direct measurements measurements carried out by a third party using the method detailed for a requirement 3.2 Symbols and abbreviations Symbols and units used in this document: d Nis the thickness of the product m K is the fa
39、ctor related to number of test results is the thermal conductivity W/(mK) Dis the declared thermal conductivity W/(mK) Iis one test result of thermal conductivity W/(mK) 90/90is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(mK) meanis the mean thermal conductivity
40、 W/(mK) is the water vapour diffusion resistance factor n is the number of test results R Dis the declared thermal resistance m 2 K/W R 90/90is the 90 % fractile with a confidence level of 90 % for the thermal resistance m 2 K/W s is the estimate of the standard deviation of the thermal conductivity
41、 W/(mK) CR is the symbol of the declared value for crushing resistance LD is the symbol of the declared value for loose bulk density PS is the symbol of the declared particle size WR is the symbol for water repellency Abbreviated terms used in this document: EVA is vermiculite aggregate as defined i
42、n 3.1.2 EVC is coated vermiculite as defined in 3.1.3 EVH is hydrophobic vermiculite as defined in 3.1.4 EVM is premixed vermiculite as defined in 3.1.5 ITT is initial type testing 4 Requirements 4.1 General Product properties shall be assessed in accordance with Clause 5. To comply with this docume
43、nt, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. One test result for a product property is the average of the measured values on the number of test specimens given in Table 1. 4.2 For all applications 4.2.1 Thermal resistance and thermal conductivity Therm
44、al resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667. EN 14317-1:2004 (E) 7 The thermal conductivity shall be determined in accordance with Annex A and declared by the manufacturer according to the following: the reference mean temperature s
45、hall be 10 C; the measured values shall be expressed with three significant figures; the declared thermal values shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %; the declared thermal resistance, R D , shall be calculated from th
46、e thickness, d N , and the corresponding declared thermal conductivity value, D , where R D= d N / (see NOTE 3); the value of thermal conductivity, 90/90 , shall be rounded upwards to the nearest 0,001 W/(mK) and declared as Din levels with steps of 0,001 W/(mK); the value of the declared thermal re
47、sistance, R D , shall be rounded downwards to the nearest 0,05 m 2 K/W, and declared in levels with steps of 0,05 m 2 K/W; An example of the determination of the declared value of thermal conductivity is given in the Annex F. NOTE 1 for exfoliated vermiculite is normally in the range 0,05 to 0,08 W/
48、(mK). NOTE 2 A correlation between thermal conductivity and any other property specific to the manufacturers product can be used for indirect testing. NOTE 3 The declaration of the installed thermal resistance is described in prEN 14317-2. 4.2.2 Loose bulk density Loose bulk density shall be determined in accordance with EN 1097-3. However the container should be filled using a flat bottomed scoop held centrally over the container w