1、BRITISH STANDARDBS EN14529:2005Respiratory protective devices Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes onlyThe European Standard EN 14529:2005 has the status of a British Stand
2、ardICS 13.340.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BS
3、IBS EN 14529:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2006 BSI 2006ISBN 0 580 46889 5National forewordThis British Standard is the official English language version of EN 14529:2005.The UK participation in its preparation wa
4、s entrusted by Technical Committee PH/4, Respiratory protection, to Subcommittee PH/4/13, Breathing apparatus, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement i
5、nternational or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not p
6、urport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European commi
7、ttee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, page i, a blank page, the EN title pa
8、ge, pages 2 to 26, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIBS EN
9、 14529:2005iWARNINGThe UK, as a member of CEN, is obliged to publish EN 14529:2005 as a British Standard. However, attention is drawn to the fact that during the development of this European Standard, the UK consistently voted against its approval as a European Standard.The reason for this disapprov
10、al is as follows. The Scope of EN 14529:2005 states that this standard “. . . specifies minimum requirements for self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes only.“Such equipment i
11、s intended for use in work situations where the risk on overpressurisation of the pressure vessels with their valves due to hot environmental conditions is low.“This European Standard does not apply to apparatus for work and rescue or to diving apparatus.”During discussion of this standard by BSI Co
12、mmittee PH/4/13, which mirrors the work of CEN Committee TC79/SC6, the UK committee expressed the opinion that the self-contained open-circuit compressed air breathing apparatus with half mask covered in this standard is not a safe combination to be used in those emergency situations where wearers m
13、ay be exposed to other conditions (such as exposure in confined spaces to, or leaks of, noxious or toxic substances) that will, on the basis of a risk assessment in accordance with The Control of Substances Hazardous to Health Regulations 2002, require the combination to meet higher minimum performa
14、nce requirements for the protection of the wearer.Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIblankLicensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14529August 2005ICS 13.34
15、0.30English VersionRespiratory protective devices - Self-contained open-circuitcompressed air breathing apparatus with half mask designed toinclude a positive pressure lung governed demand valve forescape purposes onlyAppareils de protection respiratoire - Appareils deprotection respiratoire autonom
16、es circuit ouvert, aircomprim avec demi-masque et soupape la demande commande la premire inspiration, pression positive,pour lvacuation uniquementAtemschutzgerte - Behltergerte mit Druckluft(Pressluftatmer) mit Halbmaske in der Ausfhrung miteinem berdrucklungenautomaten nur fr FluchtzweckeThis Europ
17、ean Standard was approved by CEN on 1 July 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerni
18、ng such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own langua
19、ge and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
20、 Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any
21、 form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14529:2005: ELicensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEN 14529:2005 (E) 2 Contents Page Foreword 3 Introduction4 1 Scope .5 2 Normative references .5 3 Terms and definitions.6 4
22、Description 6 5 Classification.6 6 Requirements 6 7 Testing .13 8 Marking 17 9 Information supplied by the manufacturer18 Annex A (informative) Methods of measurement of the insulation resistance of the carrying container21 Annex B (informative) Marking 24 Annex ZA (informative) Clauses of this Euro
23、pean Standard addressing essential requirements or other provisions of EU Directives25 Annex ZB (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 97/23/EC (PED) .26 Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c
24、) BSIEN 14529:2005 (E) 3 Foreword This European Standard (EN 14529:2005) has been prepared by Technical Committee CEN/TC 79 “Respiratory protective devices”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an
25、identical text or by endorsement, at the latest by April 2006, and conflicting national standards shall be withdrawn at the latest by April 2006. This European Standard has been prepared under a mandate given to CEN/CENELEC by the European Commission and the European Free Trade Association, and supp
26、orts essential requirements of EU Directive(s) 89/686/EEC and 97/23/EEC. For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this European Standard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the follow
27、ing countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
28、 Switzerland and United Kingdom. Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEN 14529:2005 (E) 4 Introduction A given respiratory protective device can only be approved when the individual components satisfy the requirements of the test specification which ma
29、y be a complete European Standard or part of a European Standard and practical performance tests have been carried out successfully on complete apparatus where specified in the appropriate European Standard. If for any reason a complete apparatus is not tested then simulation of the apparatus is per
30、mitted provided the respiratory characteristics and weight distribution are similar to those of the complete apparatus. Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEN 14529:2005 (E) 5 1 Scope This European Standard specifies minimum requirements for self-cont
31、ained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes only. Such equipment is intended for use in work situations where the risk on overpressurisation of the pressure vessels with their valves due t
32、o hot environmental conditions is low. This European Standard does not apply to apparatus for work and rescue or to diving apparatus. Laboratory and practical performance tests are included for the assessment of compliance with the requirements. 2 Normative references The following referenced docume
33、nts are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 132:1998, Respiratory protective devices Definitions of terms and pi
34、ctograms EN 134:1998, Respiratory protective devices - Nomenclature of components EN 140:1998, Respiratory protective devices Half mask and quarter masks Requirements, testing, marking EN 148-1, Respiratory protective devices - Threads for facepieces - Part 1: Standard thread connection EN 148-2, Re
35、spiratory protective devices - Threads for facepieces - Part 2: Centre thread connection EN 148-3, Respiratory protective devices - Threads for facepieces - Part 3: Thread connection for M 45 x 3 EN 1964-1, Transportable gas cylinders Specification for the design and construction of refillable trans
36、portable seamless steel gas cylinders of water capacities from 0,5 litre up to and including 150 litres Part 1: Cylinders made of seamless steel with an Rmvalue of less than 1100 MPa EN 1964-2, Transportable gas cylinders Specification for the design and construction of refillable transportable seam
37、less steel gas cylinders of water capacities from 0,5 litre up to and including 150 litres Part 2: Cylinders made of seamless steel with an Rmvalue of 1100 MPa and above EN 1964-3, Transportable gas cylinders Specification for the design and construction of refillable transportable seamless steel ga
38、s cylinders of water capacity from 0,5 litre up to and including 150 litres Part 3: Cylinders made of seamless stainless steel with an Rmvalue of less than 1100 MPa EN 1975, Transportable gas cylinders - Specification for the design and construction of refillable transportable seamless aluminium and
39、 aluminium alloy gas cylinders of capacity from 0, 5 litre up to 150 litre EN 12021, Respiratory protective devices - Compressed air for breathing apparatus EN 12245, Transportable gas cylinders - Fully wrapped composite cylinders EN 13274-2:2001, Respiratory protective devices - Methods of test - P
40、art 2: Practical performance tests EN 13274-3:2001, Respiratory protective devices - Methods of test - Part 3: Determination of breathing resistance Licensed Copy: Wang Bin, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEN 14529:2005 (E) 6 EN 13274-4:2001, Respiratory protective device
41、s - Methods of test - Part 4: Flame tests EN 13274-5, Respiratory protective devices - Methods of test - Part 5: Climatic conditions 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 132:1998 and the nomenclature given in EN 134:1998 apply. 4 D
42、escription Lung governed demand compressed air escape apparatus are designed and constructed to enable the wearer to breathe air on demand from a pressure vessel(s) either via a pressure reducer and a lung governed demand valve or a lung governed demand valve connected to the half mask. The exhaled
43、air passes without re-circulation from the half mask via the exhalation valve to the ambient atmosphere. This apparatus typically comprises pressure vessel(s), body harness, lung governed demand valve, pressure indicator(s), warning device (optional), connecting hoses and tubes and a half mask. 5 Cl
44、assification Lung governed demand compressed air escape apparatus are classified according to the rated working duration (see 6.23.1) which is defined by performing a breathing machine test in accordance with 7.6.4 with a minute volume of 35 l/min (20 cycles/min, 1,75 l/stroke). Rated working durati
45、on is defined in steps of 5 minutes, starting with 5 minutes as a minimum, up to a maximum of 30 min rated working duration, since the necessary escape time is considered to be the classification. NOTE It should be recognised that the effective duration may vary according to the breathing rate. 6 Re
46、quirements 6.1 General In all tests all test samples shall meet the requirements. Wherever a test clause is referenced, all sub-clauses of the test clause shall apply, unless otherwise stated. 6.2 Ergonomics The requirements of this European Standard are intended to take account of the interaction b
47、etween the wearer, the apparatus, and where possible the working environment in which the apparatus is likely to be used. The device shall satisfy 6.3, 6.8 and 6.9. 6.3 Design The diameter of pressurised parts downstream of the shut-off valve(s) shall not exceed 32 mm. The apparatus shall be designe
48、d so as not to interfere with work activities when carried in accordance with the manufacturers instructions. The apparatus shall be so designed that there are no protruding parts or sharp edges likely to be caught on projections in narrow passages or that may hurt the wearer. Licensed Copy: Wang Bi
49、n, na, Mon Aug 07 03:47:02 BST 2006, Uncontrolled Copy, (c) BSIEN 14529:2005 (E) 7 The apparatus shall be designed to ensure its full function in any orientation. The ready for use state of the apparatus shall identify the pressure in the pressure vessel(s) prior to use and during storage. In the ready for use state the half mask shall be securely attached to the apparatus. In the case of a permanent installation of the apparatus in a storage container the pressure vessel seal shall be opened automatically upon removal from the storage conta