BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf

上传人:王申宇 文档编号:573414 上传时间:2018-12-13 格式:PDF 页数:14 大小:725.95KB
下载 相关 举报
BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf_第1页
第1页 / 共14页
BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf_第2页
第2页 / 共14页
BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf_第3页
第3页 / 共14页
BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf_第4页
第4页 / 共14页
BS EN 15765-2009 Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICPMS) after pressure digestion《食品 微量元素测定 高压溶出.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、BS EN 15765:2009ICS 67.050NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFoodstuffs Determination oftrace elements Determination oftin by inductivelycoupled plasma massspectrometry (ICP-MS) after pressuredigestionLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STAN

2、DARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 January2010 BSI 2010ISBN 978 0 580 61087 5Amendments/corrigenda issued since publicationDate CommentsBS EN 15765:2009National forewordThis Briti

3、sh Standard is the UK implementation of EN 15765:2009.The UK participation in its preparation was entrusted to TechnicalCommittee AW/-/3, Food analysis - Horizontal methods.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purp

4、ort to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 15765:2

5、009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15765 December 2009 ICS 67.050 English Version Foodstuffs - Determination of trace elements - Determination of tin by inductively coupled plasma mass spectrometry (ICP-MS) after pressure digestion Produits alimentaires - Dosage des lments trace

6、s - Dosage de ltain par spectromtrie de masse plasma induit par haute frquence (ICP-MS) aprs digestion sous pression Lebensmittel - Bestimmung von Elementspuren - Bestimmung von Zinn mit Massenspektrometrie mit induktiv gekoppeltem Plasma (ICP-MS) nach Druckaufschluss This European Standard was appr

7、oved by CEN on 7 November 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationa

8、l standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and not

9、ified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, M

10、alta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of ex

11、ploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15765:2009: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 15765:2009EN 15765:2009 (E) 2 Contents Page Foreword 31 Scope 42 Normative references

12、 43 Principle 44 Reagents .45 Apparatus and equipment 56 Procedure .67 Evaluations .78 Precision .79 Test report 8Annex A (informative) Results of the inter-laboratory test .9Bibliography . 11Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 157

13、65:2009EN 15765:2009 (E) 3 Foreword This document (EN 15765:2009) has been prepared by Technical Committee CEN/TC 275 “Food analysis - Horizontal methods”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an id

14、entical text or by endorsement, at the latest by June 2010, and conflicting national standards shall be withdrawn at the latest by June 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held res

15、ponsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, Fra

16、nce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled C

17、opy, (c) BSIBS EN 15765:2009EN 15765:2009 (E) 4 1 Scope This European Standard specifies a method for the determination of tin in foodstuffs by inductively coupled plasma mass spectrometry (ICP-MS) after pressurized digestion. The collaborative study included carrot puree, tomato puree, pineapple, m

18、ixed fruit, white wine, peach powder, tomato powder, beans powder, powdered fruit yoghurt and fish powder foodstuffs having a mass fraction of tin ranging from 2,5 mg/kg to 259 mg/kg. 2 Normative references The following referenced documents are indispensable for the application of this document. Fo

19、r dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13805, Foodstuffs Determination of trace elements Pressure digestion 3 Principle The sample is mineralized through pressurized digestion wi

20、th nitric acid and hydrochloric acid in accordance with EN 13805. The digestion solution obtained thereby is diluted and then atomised and ionised in an inductively coupled argon plasma. After extraction from the plasma by a system of sampler and skimmer cones the positive (charged) tin ions are sep

21、arated according to their mass charge ratio in a mass spectrometer and quantified in a detector system. 4 Reagents 4.1 General The concentration of tin in the reagents and water used shall be low enough not to affect the results of the determination. Solution shall be understood as an aqueous soluti

22、on unless otherwise specified. 4.2 Nitric acid, mass fraction w(HNO3) 65 %, mass concentration (HNO3) 1,4 g/ml. 4.3 Hydrochloric acid, w(HCl) 30 %, density (HCl) 1,15 g/ml. 4.4 Stock solutions 4.4.1 Tin stock solution, mass concentration (Sn) = 1 000 mg/l. 4.4.2 Rhodium stock solution (internal stan

23、dard), mass concentration (Rh) = 1 000 mg/l. 4.5 Standard solutions 4.5.1 Tin standard solution 1, mass concentration (Sn) = 50 mg/l Fill a 50 ml volumetric flask with 10 ml to 20 ml of water, add 2,5 ml of hydrochloric acid (4.3) and mix. Cool to ambient temperature, and add by means of a pipette e

24、xactly 2,5 ml of tin stock solution (4.4.1) and dilute to volume with water. This solution is stable for at least one week. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 15765:2009EN 15765:2009 (E) 5 4.5.2 Tin standard solution 2, mass conce

25、ntration (Sn) = 1,0 mg/l Fill a 50 ml volumetric flask with 10 ml to 20 ml of water, add 2,5 ml of hydrochloric acid (4.3) and mix. Cool to ambient temperature, and add by means of a pipette exactly 1,0 ml of tin standard solution 1 (4.5.1) and dilute to volume with water. This solution is stable fo

26、r one week. 4.5.3 Rhodium standard solution, mass concentration (Rh) = 10 mg/l Fill a 50 ml volumetric flask with 10 ml to 20 ml of water, add 2,5 ml of hydrochloric acid (4.3) and mix. Cool to ambient temperature, and add by means of a pipette exactly 0,5 ml of rhodium stock solution (4.4.2) and di

27、lute to volume with water. This solution is stable for at least four weeks. 4.6 Calibration solutions The following concentrations of the calibration solutions are examples and may be changed according to the sensitivity of measuring instrument and the concentration range to be investigated. Care sh

28、all be taken that calibration is carried out within the linear range of the detector system while paying attention to the varying frequency of isotopes. The quantity of internal standard added should be sufficient enough to obtain a stable and reproducible intensity. For calibration at least three c

29、alibration solutions of different concentration shall be used. The acid concentration should correspond to the one in the measuring solution. The preparation of the following solutions is given as an example: Calibration solutions with mass concentrations of 5 g/l, 10 g/l, 20 g/l and 40 g/l. The cal

30、ibration solutions are prepared from the tin standard solution 2 (4.5.2) according to following procedure: Fill four 50 ml volumetric flasks with 10 ml to 20 ml of water, add 0,5 ml of nitric acid (4.2) and 0,1 ml of hydro-chloric acid (4.3) and mix. Cool to ambient temperature, and pipette exactly

31、the same amount of internal standard, e.g. 0,5 ml of rhodium standard solution (4.5.3), into each of the measuring flasks. Then, for the calibration solutions of mass concentrations of 5 g/l, 10 g/l, 20 g/l and 40 g/l, pipette exactly 0,25 ml, 0,50 ml, 1,0 ml and 2,0 ml of the standard solution 2 (4

32、.5.2), respectively, into the four separate 50 ml volumetric flasks and make up to volume with water. These solutions shall be freshly prepared on each day of measurement. The calibration solutions described here shall be understood as examples. The concentrations prepared shall be in the linear ran

33、ge of the ICP-MS detector system. Furthermore, the acid concentration of the calibration solutions shall be matched to the amounts of acid being present in the diluted digestion solution. 4.7 Blank solution (blank solution) The blank solution contains water, nitric acid and hydrochloric acid in amou

34、nts that correspond to the concentrations in the measurement solution, for example 0,5 ml of nitric acid (4.2) and 0,1 ml of hydrochloric acid (4.3) in 50 ml as well as the same amount of internal standard (0,5 ml rhodium standard solution (4.5.3) as used for the calibration solutions in 50 ml. 5 Ap

35、paratus and equipment 5.1 General All apparatus and equipment that come into direct contact with the sample and solutions shall be pre-cleaned appropriately. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 15765:2009EN 15765:2009 (E) 6 5.2 ICP

36、-MS instrument with inductively coupled argon plasma as ionisation unit, sample feeding and nebulising system as well as an instrument controlling unit and an evaluation unit. 6 Procedure 6.1 Digestion of the sample Mineralize the sample by pressurized digestion in accordance with EN 13805. For the

37、quantification of tin, add 0,5 ml to 1 ml of hydrochloric acid (4.3) to the digestion vessel, which contains nitric acid (4.2) used for digestion, at an amount that corresponds to the amount of nitric acid. Do not add the hydrochloric acid until the spontaneous reaction with nitric acid has subsided

38、. After addition of the hydrochloric acid close the digestion vessel immediately in order to avoid loss of active chlorine. Start pressurized digestion shortly thereafter. The digestion requirements are based on the specifications of the instrument manufacturer, the reactivity of the sample, the max

39、imum pressure stability of the digestion vessel and the attainable temperature. EXAMPLE 1 Precisely weigh 0,4 g to 0,5 g of dry sample (residual moisture of less than 20 %) into a 100 ml digestion vessel and add 5 ml of nitric acid (4.2). Carefully shake the digestion vessel to prevent clots from fo

40、rming in the sample. After the spontaneous reaction has subsided, add 1 ml of hydrochloric acid (4.3) and close the digestion vessel as quickly as possible. For samples with a higher degree of moisture content, the weighed quantities can be increased. The digestion solution that results from the pre

41、ssurized digestion according to EN 13805 is made up to a defined volume, e.g. 20 ml, by water. This solution is diluted, using water, by a factor of 10 or higher for the subsequent determination of tin. It is important that the amount of internal standard is exactly the same, both in the measurement

42、 solutions and in the calibrations solutions. EXAMPLE 2 For preparation of the measurement solution directly in the vessel used for measurement, pipette exactly 1,0 ml digestion solution and 0,5 ml rhodium standard solution (4.5.3) into the measurement vessel and make up with water to 10 ml. This so

43、lution should be measured on the day of preparation. 6.2 Inductively coupled plasma mass spectrometry 6.2.1 ICP-MS operating conditions Set the instrument according to the manufacturers specifications and ignite the plasma. Following sufficient warming up and stabilization of the instrument, optimis

44、e the settings. 6.2.2 Determination by ICP-MS Once the instrument is optimised start the measurements. For evaluation tin isotopes of the masses 117 and 118 shall be used. The internal standard rhodium is analysed for the mass 103. Correction with internal standard is implemented by the method setti

45、ngs of the instrument software. Measure the blank solution (4.7) and calibration solutions (4.6) and use the counting rate (counts/s) and concentrations to generate a calibration curve. Determine the linear range of the calibration function. The measurement solution is aspirated and measured. Use th

46、e calibration curve to convert the determined counting rate into concentration units. 6.3 Quality control For quality control, analyse a reference material with reliably known content of tin in parallel to each series of measurements. Include all procedural steps starting at the digestion. This also

47、 applies to each series of digestions including all procedural steps to prepare and measure blank solutions. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 02/04/2010 07:43, Uncontrolled Copy, (c) BSIBS EN 15765:2009EN 15765:2009 (E) 7 7 Evaluations 7.1 Calculation of the tin content in food

48、stuffs Calculate the tin content, w, in milligrams per kilogram of sample or , in milligrams per litre of sample according to Equation (1): w or = 000100010001EFVa(1) where a is the mass concentration of tin of the measurement solution, in micrograms per litre (g/l); V is the volume of the digestion

49、 solution diluted to volume, in millilitres (ml); E is the initial sample mass, in grams (g), or the initial sample volume, in millilitres (ml); F is the dilution factor ( 10). 7.2 Limit of quantification The ICP-MS instrument should be able to quantify 1 g/l tin in the diluted digestion solution. When using ICP-MS, the limit of quantification in the digestion solution prepared according to EN 13805 is mainly affected by the matrix content. Regarding the foodstuff, the limit of quantificatio

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1