1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 15869-3:2010Inland navigation vessels Electrical shore connection,three phase current 400 V, upto 63 A, 50 HzPart 3: On-board unit, safety requirementsBS EN 15869-3:2010 BR
2、ITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15869-3:2010.The UK participation in its preparation was entrusted to TechnicalCommittee SME/32/-/11, Ships and marine technology - Intermodal,inland navigation and short sea shipping.A list of organizations represen
3、ted on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 6397
4、9 1ICS 47.020.60; 47.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 April 2013.Amendments issued since publicationDate Text affectedBS EN 15869-3:2010EUROPE
5、AN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15869-3 February 2010 ICS 47.020.60; 47.060 English Version Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements Bateaux de navigation intrieure - Connexion au
6、 rseau lectrique terrestre, courant triphas 400 V, 63 A, 50 Hz -Partie 3: Unit bord, exigences de scurit Fahrzeuge der Binnenschifffahrt - Elektrischer Landanschluss, Drehstrom 400 V, bis 63 A, 50 Hz - Teil 3: Bordseitiger Teil, sicherheitstechnische Anforderungen This European Standard was approved
7、 by CEN on 25 December 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national s
8、tandards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notifi
9、ed to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembo
10、urg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights
11、 of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15869-3:2010: EBS EN 15869-3:2010EN 15869-3:2010 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Safety requirements 7 4.1 Cable set .7
12、 4.2 Feed unit .9 4.2.1 General9 4.2.2 Mechanical safety 10 4.2.3 Electrical safety10 5 Designation 10 5.1 Cable set .10 5.2 Feed unit .10 6 Marking .11 6.1 Cable set .11 6.2 Feed unit .11 7 Manufacturers declaration of conformity.11 Figures Figure 1 Example of a cable set with extension 7 Figure 2
13、Block diagram of a feed unit. 9 Tables Table 1 Maximum length of cable set and extension 8 BS EN 15869-3:2010EN 15869-3:2010 (E) 3 Foreword This document (EN 15869-3:2010) has been prepared by Technical Committee CEN/TC 15 “Inland navigation vessels”, the secretariat of which is held by DIN. This Eu
14、ropean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2010, and conflicting national standards shall be withdrawn at the latest by August 2010. EN 15869, Inland navigation vessels Electrical shore conne
15、ction Three-phase current 400 V, up to 63 A, 50 Hz comprises: Part 1: General requirements Part 2: Onshore unit, safety requirements Part 3: On-board unit, safety requirements According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound
16、 to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Swi
17、tzerland and the United Kingdom. . BS EN 15869-3:2010EN 15869-3:2010 (E) 4 Introduction Inland navigation vessels are equipped with a variety of electrical loads operating at 230 V or 400 V. While underway, continuous electrical power supply is provided by the onboard system from generators driven b
18、y diesel engines. When the vessel is berthed, these generators have to remain in operation if there is no suitable onshore power supply available. In some cases, this leads to intense noise pollution both for the crew on the vessel itself and on other vessels lying alongside and also for residents a
19、shore. The exhaust fumes are an additional pollution factor. The electrical shore connections specified in this standard make it possible to provide the vessels with an electrical power supply while berthed and to eliminate noise and exhaust pollution. This calls for a uniform Europe-wide connection
20、 that can be activated and deactivated by the vessels crew in all ports and berths, if possible, without requiring any assistance from shore-based personnel. This standard contains electrical safety requirements for the prevention of hazards in making, using and breaking the shore connection. Furthe
21、rmore, cashless settlement for the electricity used shall be possible, ideally a standard Europe-wide payment system. Electrical shore connections with a permissible current of over 63 A as used for passenger ships with a hotelling function are not covered by this standard. BS EN 15869-3:2010EN 1586
22、9-3:2010 (E) 5 1 Scope This European Standard specifies requirements applicable to equipment for shore-to-vessel supply of three-phase 400 V electrical power up to 63 A and a frequency of 50 Hz to berthed inland navigation vessels. This part of the European Standard specifies safety requirements for
23、 the connection cable and the on-board unit of the electrical shore connection. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the re
24、ferenced document (including any amendments) applies. EN 15869-1, Inland navigation vessels Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz Part 1: General requirements EN 15869-2, Inland navigation vessels Electrical shore connection, three phase current 400 V, up to 63 A,
25、 50 Hz Part 2: Onshore unit, safety requirements EN 60076-1, Power transformers Part 1: General (IEC 60076-1:1993, modified) EN 60309-1, Plugs, socket-outlets and couplers for industrial purposes Part 1: General requirements (IEC 60309-1:1999) EN 60309-2, Plugs, socket-outlets and couplers for indus
26、trial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories (IEC 60309-2:1999) EN 60309-4, Plugs, socket-outlets and couplers for industrial purposes Part 4: Switched socket-outlets and connectors with or without interlock (IEC 60309-4:2006, modified) EN 6
27、0529, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989) HD 22.16 S2, Cables of rated voltages up to and including 450/750 V and having cross-linked insulation Part 16: Water resistant polychloroprene or equivalent synthetic elastomer sheathed cables 3 Terms and definitions For
28、the purposes of this document, the following terms and definitions apply. 3.1 electrical shore connection equipment consisting of electrical power-supply station, cable set and feed unit for the supply of electrical power to inland navigation vessels in ports and at berths EN 15869-1:2010 3.2 electr
29、ical power-supply station shore-side part of the electrical shore connection with one or more connector units EN 15869-1:2010 BS EN 15869-3:2010EN 15869-3:2010 (E) 6 3.3 connector unit unit for connecting an inland navigation vessel EN 15869-1:2010 3.4 activation medium system for activating the sup
30、ply of power and cashless settlement of the costs EN 15869-1:2010 3.5 feed unit all the onboard devices for receiving the electrical power on board EN 15869-1:2010 3.6 connection cable insulated, protected (e.g. fire protection) electrical component 3.7 cable set connection cable fitted with plug an
31、d coupler (flexible cable) or plug and permanently installed on one end on the vessel BS EN 15869-3:2010EN 15869-3:2010 (E) 7 4 Safety requirements 4.1 Cable set Key 1 plug 2 coupler 3 cable coupler 4 connection cable 1 + 4 + 2 flexible cable set a field for marking Figure 1 Example of a cable set w
32、ith extension An H07RNF cable according to HD 22.16 S2 shall be used as the cable set as shown in Figure 1. The cross-section shall be as indicated in Table 1. BS EN 15869-3:2010EN 15869-3:2010 (E) 8 Table 1 Maximum length of cable set and extension Cross-section mm2 Max. length for 16 A m Max. leng
33、th for 32 A m Max. length for 63 A m 5 2,5 70 not permissible not permissible 5 4 130 not permissible not permissible 5 6 220 110 not permissible 5 10 180 not permissible 5 16 280 140 It is recommended selecting the cable length such that the mass of one single cable set does not exceed 20 kg. For h
34、eavy cable sets, mobile cable drums should be used NOTE Five-core cables have the following approximate masses: 5 2,5 mm 0,26 kg/m, 5 4 mm 0,48 kg/m, 5 6 mm2 0,62 kg/m, 5 10 mm2 1,07 kg/m, 5 16 mm2 1,53 kg/m. The cable set may be permanently attached to the feed unit (type A) or be connected by mean
35、s of a plug-and-socket connection (type B). The plug-and-socket connections shall meet the requirements of EN 60309-1, EN 60309-2 and EN 60309-4. The cable set shall be provided by the vessel. Cable sets may be extended. The cross-sections of all the connection cables used shall be as shown in Table
36、 1 and be designed according to the overall length of the cable set. BS EN 15869-3:2010EN 15869-3:2010 (E) 9 4.2 Feed unit 4.2.1 General Key 1 equipment plug or permanently attached cable according to EN 15869-1 2 phase-sequence indicator 3 all-pole switch according to EN 15869-1 4 isolating transfo
37、rmer according to EN 15869-1 5 overload protector 6 indicator light 7 interlock against on-board supply system generators 8 main control panel a The values given apply to the 16 A connection. For the 32 A connection, 32 A and 22 kVA apply For the 63 A connection, 63 A and 44 kVA apply Figure 2 Block
38、 diagram of a feed unit The feed unit (see Figure 2) shall be prefabricated for permanent installation on board. BS EN 15869-3:2010EN 15869-3:2010 (E) 10 The feed unit shall be supplied with instructions containing details on how the unit is to be safely installed (e.g. permanent installation, freed
39、om of movement when using it, height of the plug-and-socket device, prevention of the risk of falling, keeping walkways clear, reducing the effects of the weather, etc.). 4.2.2 Mechanical safety The housing of the feed unit shall be sufficiently mechanically resistant, durable, flame-resistant and n
40、on-hygroscopic. It shall not be possible to open it with without tools. The feed unit shall be constructed for ambient temperatures of 20 C to +60 C. 4.2.3 Electrical safety If the feed unit is not integrated in the onboard electrical switchgear cabinet, it shall have a connection block to connect a
41、 cable leading to this control panel. The feed unit shall not have any socket outlets fitted. . The feed unit shall only be connectable to the onboard electrical power supply by a power transformer in accordance with EN 60076-1. Feed units constructed for deck installation shall have at least IP 55
42、degree of protection in accordance with EN 60529. Each onboard electrical power supply shall have one feed unit only. If there is more than one plug-and-socket connection, they shall be interlockable against each other. The plug-and-socket connection shall meet the requirements of EN 60309-1, EN 603
43、09-2 and IEC 60309-4. A phase-sequence indicator shall be installed. . The feed from the electrical shore connection shall be all-pole switchable on the vessel-side and protected against overload. The switches and overload protector may be located in the main control panel of the vessel. An interloc
44、k shall be provided to prevent parallel operation of the onboard generators with the shore-side electricity supply. It shall be visible on the feed unit whether the connection is live or not. 5 Designation 5.1 Cable set Designation of a cable set of an electrical shore connection according to Part 3
45、 (3) of this standard, with a plug-and-socket connector on both ends (type B) (B) and 50 m in length (50) for a current of 32 A (32): Cable set EN 15869-3 B 50 32 5.2 Feed unit Designation of a feed unit of an electrical shore connection according to Part 3 (3) of this standard, with a permanently a
46、ttached cable (type A) (A) and 20 m in length (20): Feed unit EN 15869-3 A 20 Designation of a feed unit of an electrical shore connection according to Part 3 (3) of this standard, without a permanently attached cable (type B) (B): Feed unit EN 15869-3 B BS EN 15869-3:2010EN 15869-3:2010 (E) 11 6 Ma
47、rking 6.1 Cable set The connection cable of the electrical shore connection shall have permanent markings on the shore-side plug-and-socket connection that include at least the following details: “cable set according to EN 15869-3“; manufacturer or manufacturers mark; cross-section; length in metres
48、. 6.2 Feed unit The feed unit of the electrical shore connection shall have permanent markings that include the following details: EN 15869-3; manufacturer or manufacturers mark; notice with at least the following details: “Supply of only one electrical power-supply station according to EN 15869-2 b
49、y means of a cable set according to EN 15869-3. Supply to on-board systems of other vessels only if they have a feed unit according to EN 15869-3 and only by means of a cable set according to EN 15869-3. If the cable set is extended: note the cross-sections of the connection cable!“. table of maximum length data for cable sets and extensions. 7 Manufacturers declaration of conformity The manufacturer declares the conformity of the electr