BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf

上传人:twoload295 文档编号:573498 上传时间:2018-12-13 格式:PDF 页数:26 大小:1.03MB
下载 相关 举报
BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf_第1页
第1页 / 共26页
BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf_第2页
第2页 / 共26页
BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf_第3页
第3页 / 共26页
BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf_第4页
第4页 / 共26页
BS EN 15882-2-2015 Extended application of results from fire resistance tests for service installations Fire dampers《服务设施耐火试验结果的扩展应用 防火档板》.pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 15882-2:2015Extended application of resultsfrom fire resistance tests forservice installationsPart 2: Fire dampersBS EN 15882-2:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15882-2:2015.The UK participation in its preparati

2、on was entrusted to TechnicalCommittee FSH/22/-/4, Fire resistance tests for dampers, seals andsmoke extraction.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Use

3、rs are responsible for its correctapplication. The British Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 86317 2ICS 13.220.99Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of t

4、heStandards Policy and Strategy Committee on 30 April 2015.Amendments issued since publicationDate Text affectedBS EN 15882-2:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15882-2 April 2015 ICS 13.220.99 English Version Extended application of results from fire resistance tests for servi

5、ce installations - Part 2: Fire dampers Application tendue des rsultats des essais de rsistance au feu des installations de service - Partie 2 : Clapets rsistant au feu Erweiterter Anwendungsbereich der Ergebnisse aus Feuerwiderstandsprfungen fr Installationen - Teil 2: Brandschutzklappen This Europ

6、ean Standard was approved by CEN on 11 January 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references co

7、ncerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member

8、into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France

9、, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMI

10、TEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15882-2:2015 EBS EN 15882-2:2015EN 15882-2:2015 (E) 2 Contents Page Foreword 3 Introduction .4 1 S

11、cope 5 2 Normative references 5 3 Terms and definitions .6 4 Determination of worst case .6 5 Conditions and application rules .6 5.1 Change of fixing damper to supporting construction .6 5.2 Multiple damper assemblies .7 5.2.1 E Classification only 7 5.2.2 EI, E-S, EI-S Classifications 8 5.3 Altern

12、ative penetration seals 8 6 Influence of parameters and factors on fire damper performance .9 7 Critical parameters and factors 9 7.1 General 9 7.2 Common operational parameters and factors 9 7.3 Constructional parameters .9 7.4 Parameters of components of damper . 10 7.5 Installing parameters 11 8

13、Methodology 12 9 Report of the extended application analysis . 20 Bibliography . 22 BS EN 15882-2:2015EN 15882-2:2015 (E) 3 Foreword This document (EN 15882-2:2015) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European

14、Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2015 and conflicting national standards shall be withdrawn at the latest by October 2015. Attention is drawn to the possibility that some of the elements

15、of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. EN 15882, Extended ap

16、plication of results from fire resistance tests for service installations consists of the following parts: Part 1: Ducts Part 2: Fire dampers Part 3: Penetration seals Part 4: Linear joint seals According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following

17、countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway

18、, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 15882-2:2015EN 15882-2:2015 (E) 4 Introduction It should be noted that fire-resisting dampers are special products that are exposed to different conditions to other elements of construct

19、ion; in particular they are subjected to significantly different pressure regimes. Also, integrity is evaluated by leakage measurements. Consequently, this European Standard may adopt a different approach to other extended field of application standards, with more emphasis on testing. BS EN 15882-2:

20、2015EN 15882-2:2015 (E) 5 1 Scope This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. I

21、t also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction. This European Standard explains the principles behind how a co

22、nclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved. This European Standard does not cover dampers used for smoke control. This European Standard only applies to extended fields of application based on tests successfully u

23、ndertaken to EN 1366-2. Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10 % or 12 min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individua

24、lly consequently E (134 min achieved) may be extended, but EI (61 min achieved) may not be extended for a classification of EI60. Additionally, leakage determined during such tests is to be at least 10 % below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN 13

25、501-3 before the EXAP rules can be applied. The 10 % below the leakage limits is to be fulfilled for the extended period in addition to the classification period. By application of this European Standard, it should be possible to identify what specifications should be tested to maximize the field of

26、 application. Some information on test programmes is given for guidance purposes. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For unda

27、ted references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1, Fire resistance tests - Part 1: General Requirements EN 1366-1:2014, Fire resistance tests for service installations - Part 1: Ventilation ducts EN 1366-2, Fire resistance tests for service i

28、nstallations - Part 2: Fire dampers EN 13501-3, Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers EN 15882-1, Extende

29、d application of results from fire resistance tests for service installations - Part 1: Ducts ISO 10294-4, Fire resistance tests - Fire dampers for air distribution systems - Part 4: Test of thermal release mechanism BS EN 15882-2:2015EN 15882-2:2015 (E) 6 3 Terms and definitions For the purposes of

30、 this document, the terms and definitions given in EN 1363-1 and EN 1366-2 and the following apply. 3.1 multiple section assemblies assemblies of individual damper units to form larger units 3.2 horizontal orientation of damper position of the damper mounted horizontally EXAMPLE When installed in th

31、e plane of a floor or a ceiling. 3.3 vertical orientation of damper position of the damper mounted vertically, e.g. when installed in the plane of a wall 3.4 supporting construction construction used as part of the test assembly to support the test specimen and to fill in the furnace aperture 3.5 st

32、andard supporting construction supporting construction that has known fire behaviour and for which a Direct Field of Application has been established 4 Determination of worst case In certain circumstances a rule can call for a new test to be undertaken. To avoid having to re-test everything, a deter

33、mination shall be made of worst case. Firstly consider the classification required: E, EI, E-S, EI-S. Consider all the test reports that give the required classification. Determine which criteria failed first in each test. The resulting worst case will be the one where the time to failure of each an

34、d any of the parameters was the lowest. If the test periods show that none of the criteria failed before the classification period plus 10 % or 12 min, then the supporting construction shall be considered. The worst case shall be with the fire damper mounted in the lightest construction in terms of

35、mechanical stability. The sponsor may pick a heavier supporting construction, but then any extended field of applications shall only apply to this supporting construction and those heavier and more dense as per direct field of application. The method of determination of worst case and the related ex

36、tended fields of application shall be reported in the extended field of application report. 5 Conditions and application rules 5.1 Change of fixing damper to supporting construction a) No change in the location of the fixings relative to the damper and the supporting construction shall be permitted.

37、 The pitch between the fixings shall not be increased. BS EN 15882-2:2015EN 15882-2:2015 (E) 7 b) Alternative fixings may be used if their performance is proven by fire test, stress, linear expansion and loading information data. Any other information available may be considered. c) Any alternative

38、fixings shall be included as part of the extended field of application report. d) Hanger and relating anchor information shall be assessed in accordance with EN 15882-1. 5.2 Multiple damper assemblies 5.2.1 E Classification only 5.2.1.1 Method To allow the use of multiple assemblies of E classified

39、fire dampers, either side by side or on top of each other, the following test shall be performed. An assembly consisting of fire dampers that have already successfully gained a classification conforming to EN 13501-3 shall be made and installed into a supporting construction using the proposed metho

40、d. A fire damper selected using the worst case method in accordance with Clause 4 shall be made into an assembly as shown in Figure 1. This will allow the other EXAP rules from the tables which follow to apply to multi-section units, as they do to single section units. The unit to be tested shall be

41、 constructed so as to be made up of at least four sections and shall have a maximum overall size of 2 600 mm 2 600 mm. This is to allow for a small gap around the outside of the damper and a minimum span of supporting construction of 200 mm all round. See Figure 1 which is applicable to both vertica

42、l (shown) and horizontal test installations. The test method shall be generally as EN 1366-2 (note: also refer to intumescent fire damper test, if this becomes relevant), but instead of a closed plenum with a fan, an extended open duct 1 m long shall be fixed to the dampers. The plate thermometers f

43、or control of furnace temperature shall be placed at the centre of area of each fire damper section. Leakage shall not be measured. A 300 Pa differential pressure shall not be set across the unit. The criteria used shall be the integrity at all of the following: round the joint between the damper in

44、stallation and the supporting construction; any point within the damper assembly, (joints, blades, etc.); sustained flaming at any point around the perimeter or at the blades or joints. If the individual fire damper sections do not close within the first 90 s, provision shall be made to manually clo

45、se the sections after 2 min (air may be drawn into the bottom of the furnace having a cooling effect). Wire thermocouples shall be placed at each thermal sensing element for information purposes. This information shall be recorded. Classification will be as the original single section units with reg

46、ard to the E classification as long as the above integrity criteria are fulfilled. BS EN 15882-2:2015EN 15882-2:2015 (E) 8 5.2.1.2 Field of application If, due to the size restriction of 2 600 mm 2 600 mm, the assembly is made up of four individual units which are smaller than or of the same size as

47、 the original single unit tested, assemblies for application may be made of units up to the single unit size tested. EXAMPLE 1 An assembly of four units with an overall size of 2 600 mm 2 600 mm, made from individual units with overall size 1 300 mm 1 300 mm, representing a single section size teste

48、d of 1 500 mm 1 300 mm, allows an assembly of overall size 3 000 mm 2 600 mm to be used. If the assembly is made up of four or more units, leading to whatever overall size, the size of unit to be used shall have been tested previously as a single unit. For application, the units then used to make up

49、 assemblies shall not exceed the size of the units tested as part of the assembly. This test may not be used to allow larger units to be back assessed to single sections for classification to EN 13501-3: EXAMPLE 2 An assembly of 6 units of individual overall size 600 mm 600 mm, giving an assembly size of 1 200 mm 1 800 mm, allows the use of multiple assemblies of units of individual size 600 mm 600 mm. If the individual unit tested was 1 000 mm 1 000 mm, the use of this to build assemblies is not now permitted as this could have been ass

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1