BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf

上传人:吴艺期 文档编号:574550 上传时间:2018-12-13 格式:PDF 页数:12 大小:291.17KB
下载 相关 举报
BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf_第1页
第1页 / 共12页
BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf_第2页
第2页 / 共12页
BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf_第3页
第3页 / 共12页
BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf_第4页
第4页 / 共12页
BS EN 50117-3-1996 Coaxial cables used in cabled distribution networks - Sectional specification for outdoor drop cables《电缆分布网络中用的同轴电缆 室外接地电缆的分规范》.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 50117-3:1996Incorporating Corrigendum No. 1Coaxial cables used in cabled distribution networks Part 3: Sectional specification for outdoor drop cablesThe European Standard EN 50117-3:1996 has the status of a British StandardICS 33.120.10BS EN 50117-3:1996This British Standard,

2、having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 August 1996 BSI 17 March 2006The following BSI references relate to the work on this standard:Committee reference EPL/46/1Special announ

3、cement in BSI News Update May 1996ISBN 0 580 26022 4Committees responsible for this British StandardThe preparation of this British Standard was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, RF connectors and accessories for cabling and signalling, to Subcommittee EPL/46/1,

4、Communication cables, on which the following bodies were represented:AEA TechnologyBritish Approvals Services for CablesBritish Broadcasting CorporationBritish Cable Makers ConfederationBritish Railways BoardBritish Telecommunications plcCable Communication AssociationConfederation of Aerial Industr

5、iesERA TechnologyFederation of the Electronics IndustryLondon UndergroundMinistry of DefenceSociety of Cable Television EngineersAmendments issued since publicationAmd. No. Date Comments15845 Corrigendum No. 1 March 2006 See national forewordBS EN 50117-3:1996 BSI 17 March 2006 iContentsPageCommitte

6、es responsible Inside front coverNational foreword iiForeword 21Scope 32 Normative references 33 Definitions 34 Materials and cable construction 36 Identification marking and labelling 39 Materials and cable construction tests 410 Mechanical and thermal characteristics 411 Electrical characteristics

7、 measurement and test methods 512 Quality assessment procedures 5List of references Inside back coverBS EN 50117-3:1996ii BSI 17 March 2006National forewordThis British Standard has been prepared by Subcommittee EPL/46/1 and is the English language version of EN 50117-3:1996, Coaxial cables used in

8、cabled distribution networks Part 3: Sectional specification for outdoor drop cables, published by the European Committee for Electrotechnical Standardization (CENELEC).This Part should be read in conjunction with BS EN 50117-1:2002. Together with BS EN 50117-1:2002, BS EN 50117-2-1: 2005, BS EN 501

9、17-2-2:2004, BS EN 50117-2-3:2004 and BS EN 50117-4:2004, it supersedes BS 5425-1:1986 which is withdrawn.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “Internatio

10、nal Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British

11、Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 6, an inside back cover and a back cover.This standard has been updated (see copyright date) and may have had

12、 amendments incorporated. This will be indicated in the amendment table on the inside front cover.EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 50117-3February 1996ICS 33.120.10Descriptors: Coaxial cables, cabled distribution networks, sectional specification for outdoor drop cablesEnglish versi

13、onCoaxial cables used in cabled distribution networks Part 3: Sectional specification for outdoor drop cablesCbles coaxiaux pour rseaux cbls de distribution Partie 3: Spcification intermdiaire pour cbles de raccordement usage extrieurKoaxialkabel fr Kabelverteilanlagen Teil 3: Rahmenspezifikation fr

14、 HausanschlukabelThis European Standard was approved by CENELEC on 1995-07-04. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and

15、bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsib

16、ility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Nethe

17、rlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENELECEuropean Committee for Electrotechnical StandardizationComit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B-1050 Brussels 1996 Copyright

18、 reserved to CENELEC membersRef. No. EN 50117-3:1996 EEN 50117-3:1996 BSI 17 March 20062ForewordThis European Standard was prepared by Subcommittee SC 46XA, Coaxial cables, of the Technical Committee CENELEC SC 46X, Communication cables.The text of the draft was submitted to the formal vote and was

19、approved by CENELEC as EN 50117-3 on 1995-07-04.The following dates were fixed: latest date which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1996-07-01 latest date by which the national standards conflicting with the EN hav

20、e to be withdrawn (dow) 1996-07-01EN 50117-3:1996 BSI 17 March 2006 31 ScopeThis Sectional Specification is intended to be used in conjunction with the Generic Specification EN 50117-1, Coaxial cables for use in cabled distribution networks operating at frequencies between 5 MHz and 862 MHz.This Sec

21、tional Specification applies to drop cables for outdoor applications.The purpose of the standard is to specify values and preferential characteristics of the cables, and to identify the applicable tests from the Generic Specification. Reference is made to suitable schemes for Quality Assessment.The

22、numbering of the clauses is the same as in the Generic Specification. All the clauses from the Generic Specification are applicable unless otherwise stated in this Sectional Specification. Any variations from the Generic Specification are also detailed in this specification.2 Normative referencesThi

23、s European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these public

24、ations apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments).EN 50117-1, Coaxial cables used in cabled distribution networks Part 1: Generic specification. HD 624.

25、4, Materials used in communication cables Part 4: PE sheathing (under consideration). 3 DefinitionsTerminology, units of measure and symbols are the same as in the Generic Specification.4 Materials and cable construction4.3 DielectricUnless otherwise specified nominal cable diameter over the dielect

26、ric should preferably be selected from the following: 4.4 Outer conductor or screenWhen braiding is used, the braid angle according to 3.2.2.1 shall be between 15 and 45. The coverage factor according to 3.2.2.4 shall be greater than or equal to 65 %, or, when the cable is provided with a metal foil

27、, greater than or equal to 25 %. These values are also valid for cables with two bidirectional layers of helically wound wires.4.5 SheathThe sheaths of cables covered by this Sectional Specification shall be in polyethylene (PE). Sheaths shall be in black PE for aerial applications.For aerial figure

28、 eight cables, the messenger shall be solid or stranded, made from galvanized or phosphated steel, or aluminium alloy wires.The messenger type shall be specified in the Detail Specifications.NOTE Tests on messenger wires remain under consideration.6 Identification marking and labelling6.2 Sheath mar

29、kingCables shall be marked on the outer sheath withi) Cable typeii) Supplier identificationat least once per metre.3,7 mm 4,8 mm 6,9 mm 7,2 mmEN 50117-3:19964 BSI 17 March 2006Additional marking is permissible provided i) and ii) above are clearly identifiable. Sheath marking shall not be easily rem

30、ovable.9 Materials and cable construction tests9.4 OvalityNot applicable.9.5 Carbon black contentApplicable for black PE sheaths only.9.6 Tensile strength and elongation after break for metalsApplicable only for copper inner conductors.9.7 Tensile strength and elongation at break for metalsApplicabl

31、e only for copper clad steel inner conductors.9.8 Torsion test for copper clad metalsApplicable only for copper clad steel inner conductors.9.9 Tensile strength and elongation for plasticsApplicable on the outer sheath of the cable.RequirementsPlastic materials used in the construction of these cabl

32、e shall meet the requirements of HD 624 as follows: 9.10 FlammabilityNot applicable.10 Mechanical and thermal characteristics10.1 Adhesion of dielectricThe test shall be performed to determine the value of the adhesion of the dielectric to the inner conductor.The application of this test on semi air

33、 spaced cables is under consideration.The adhesion of the dielectric to the inner conductor, Fa, shall be given in MPa by the following:Fa = F/(*d*l)where Fa is in MPa RequirementsThe maximum value shall be 1,0 MPa.The minimum value shall be 0,1 MPa.Where the diameter of the inner conductor is small

34、er than 1,6 mm the test shall be performed on a 25 mm sample length (l). Otherwise it shall be performed on a 50 mm sample length.10.2 Bending10.2.2 FlexingNot applicable.10.4 Crush resistance of cableApplicable with an applied load of F = 700 N.The measurement will be done in accordance with 11.9.2

35、 with a rise time of 1 ns.After a recovery time of no more than 5 min the maximum irregularity shall be less than 1 %.Polyethylene sheaths HD 624.4F is the strip force in Newtonsd is the diameter of the inner conductor in mml is the length of the sample in mmEN 50117-3:1996 BSI 17 March 2006 510.6 C

36、limatic tests10.6.1 Climatic sequenceApplicable.The cables shall comply with one of the two following classes:i) Class 40/70/4 (IEC 68)ii) Class 20/70/4 (IEC 68)10.6.2 Damp heatNot applicable.11 Electrical Characteristics Measurement and test methods11.2 Insulation resistanceApplicable.RequirementTh

37、e insulation resistance shall be not less than 104M5.km.11.3 Voltage test of dielectricApplicable with a voltage of 2 kV d.c or 1,5 kV a.c. rms.11.5 Characteristic impedance11.5.1 Mean characteristic impedanceThe mean characteristic impedance shall be 75 5 3 5.11.6 Return lossApplicable, with requir

38、ed values in accordance with the following table:NOTE is the longitudinal loss at 800 MHzIn each frequency band, 3 peak values up to 4 dB lower than the specified limit are permissible.11.7 Relative propagation velocity (velocity ratio)The value may be given in the Detail Specification for informati

39、on.11.8 Longitudinal lossThe longitudinal loss shall not exceed the values stated in the Detail Specification.The values shall be given for at least the following frequencies:5 50 100 200 400 800 MHz11.9 Regularity of impedanceThe measurement shall be performed on both ends of delivery lengths.When

40、method A is used the regularity shall be better than 40 dB.When method B is used the regularity shall be better than 1 %.11.10 Screening attenuationThe screening attenuation shall be measured after subjecting the cable length to the test of 10.2.1 and shall be not less than 75 dB from 30 MHz up to 1

41、 000 MHz.11.11 Transfer impedanceUnder consideration.12 Quality assessment proceduresUnder consideration.5 30 MHz 30 470 MHz 470 862 MHz 18 dB/100 m 23 dB 23 dB 20 dB 18 dB/100 m 20 dB 20 dB 18 dB6blankBS EN 50117-3:1996 BSI 17 March 2006List of referencesSee national foreword.BS EN 50117-3:1995BSI3

42、89 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are update

43、d by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British St

44、andard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receiv

45、e the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-

46、.In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards

47、through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members

48、 of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding onl

49、ine access to British Standards via British Standards Online can be found at http:/www.bsi- information about BSI is available on the BSI website at http:/www.bsi-.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a r

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1