1、BRITISH STANDARDBS EN 60155:1995IEC 155:1993Incorporating amendments nos. 1 and 2g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58The European Standa
2、rd EN 60155:1995, incorporating amendments A1:1995 and A2:2007, has the status of a British StandardICS 29.140.30Glow-starters for fluorescent lampse UK participation in its preparation was entrusted to Technical Committee Lamps.organizations represented on this committee can be obtained on request
3、retary.BS EN 60155:1995National forewordThiEN 601wiThe stthe text by the IbyThCPL 34/1, A list of to its secThis British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 July
4、1995 BSI 2007The following BSI references relate to the work on this standard:Committee reference CPL/34/1Draft for comment 91/28809 DCISBN 0 580 24182 3Amendments issued since publicationAmd. No. Date Comments9126 September 199616940 28 February 2007 See national forwordThis publication does not pu
5、rport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.s British Standard was published by BSI. It is the UK implementation of 55:1995, incorporating amendment A1:
6、1995 and A2:2007. It is identical th IEC 60155:1993, incorporating amendment 1:1995 and 2:2006.art and finish of text introduced or altered by amendment is indicated in tags !“. Tags indicating changes to IEC text carry the number of EC amendment. For example, text altered by IEC amendment 1 is indi
7、cated !“.EUROPISCHE NORMICS 29.140.30Descriptors: StEnglish versionInterrupteurs damorlampes fluoresc(CEI 155:1993)Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.responsibility of a CENELEC member into its own lan
8、guage and notified to the Central Secretariat has the same status as the official versions.CENELECEuropean Committee for ElectrotechnicalektrotechniStassart 3Comit Europen de Normalisation EEuropisches Komitee fr ElCentral Secretariat: rue de 1995 Copyright reserved to CENELEC membersStandardization
9、lectrotechniquesche Normung5, B-1050 BrusselsRef. No. EN 60155:1995 ECENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United
10、Kingdom.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by tr
11、anslation under the Glow-starters for fluorescent lamps(IEC 155:1993)age lueur pour ence (starters)Glimmstarter fr Leuchstofflampen(IEC 155:1993)This European Standard was approved by CENELEC on 1994-12-06; CENELEC members are bound to comply with the CEN/CENELEC Internal January 1992 + A1 December
12、1995 + A2 January 2007arter, fluorescent lamp, starting test, endurance test, deactivated lamp, type test, markingEUROPEAN STANDARDNORME EUROPENNEEN 60155EN 60155:1995ForewordThe text of the International Standard IEC 155:1993, prepared by SC 34A, Lamps, of IEC TC 34, Lamps and related equipment, wa
13、s submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 60155 on 1994-12-06 without any modification.The following dates were fixed: For products which have complied with EN 60155:1989 and its amendment A2:1993 before 1995-12-01, as shown by the manufacturer or by a certific
14、ation body, this previous standard may continue to apply for production until 2000-12-01.This standard is to be used in conjunction with EN 60081:1989, EN 60901:1990 and EN 60921:1991.Annexes designated normative are part of the body of the standard. In this standard, Annex A, Annex B and Annex ZA a
15、re normative. Annex ZA has been added by CENELEC.Foreword of amendment A1:1995The text of document 34A/586/DIS, future amendment 1 to IEC 155:1993, prepared by SC 34A, Lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amen
16、dment A1 to EN 60155:1955 on 1995-11-28.The following dates were fixed: For products which have complied with EN 60155:1995 before 1996-0-01, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 2001-09-01.Annexes designated “norm
17、ative” are part of the body of the standard.Annexes designated “informative” are given for information only.In this standard, Annex ZA is normative and Annex C is informative.Annex ZA has been added by CENELEC.Foreword to amendment A2:2007The text of document 34A/1174/FDIS, future amendment 2 to IEC
18、 60155:1993, prepared by SC 34A, Lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 60155:1995 on 2006-12-01.The following dates were fixed: Endorsement noticeThe text of amendment 2:2007 to the Internati
19、onal Standard IEC 60155:1993 was approved by CENELEC as an amendment to the European Standard without any modification. latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1995-12-01 latest date by which the nat
20、ional standards conflicting with the EN have to be withdrawn (dow) 1995-12-01 latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1996-09-01 latest date by which the national standards latest date by whic
21、h the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-09-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2009-12-01 BSI 20072conflicting with the amendment have to
22、 be withdrawn (dow) 1996-09-01EN 60155:1995ContentsPageForeword 2Introduction 5Section 1. General and safety requirements1Scope 52 Normative references 53 Definitions 54 General requirements 55 General requirements for tests 56Marking 57 Requirements and tests for safety 6Section 2. Performance spec
23、ification8 Starting test 89Endurance test 910 Deactivated lamp test 911 Information for luminaire design 11Annex A (normative) Ballasts to be used for life testing 20Annex B (normative) Starters for class II fluorescent lamp luminaires 20Annex C (informative) Information for luminaire design 22Annex
24、 D (normative) Starter contacts Suitable metals 23Annex E (informative) Guide to good practice in selection of plastic materials for starter enclosures 23Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European Publications 24Figure 1
25、 Dimensions of starters 11Figure 2 Tumbling barrel 12Figure 3 Circuit for starting test 13Figure 4 Circuit for endurance test Starters for lamp ratings up to and including 80 W13Figure 5 Circuit for endurance test Starters for lamps rated at 100 W and 125 4Figure 6 “GO” and “NOT GO” gauge for starte
26、rs 15Figure 7 “NOT GO” gauge for starters 16Figure 8 “GO” gauge for starters 17Figure B.1 Dimensions of starters for class II fluorescent lamp luminaires 21Figure B.2 “GO” gauge for starters for class II luminaires 22 BSI 2007 3Figure 9 Circuit for measurement of pulse voltage 18Figure 10 Ball-press
27、ure test apparatus 19blankEN 60155:1995Section 1. General and safety requirementsIntroductionThis standard for interchangeable glow-starters for fluorescent lamps comprises two sections: Section 1 describes the general requirements with which glow-starters shall comply in order to ensure safety, and
28、 Section 2 covers the requirements for performance.The additional requirements with which glow-starters for use in class II luminaires shall comply are specified in Annex B.1 ScopeThis standard specifies interchangeable glow-starters used with pre-heat type fluorescent lamps, hereafter called “start
29、ers”.Section 1 specifies the general and safety requirements with which starters shall comply.Section 2 specifies the performance.NOTE Starters are generally designed to operate with a range of lamps, depending on supply voltage, single lamp or series pair operation, maximum lamp voltage and lamp st
30、arting requirements.2 Normative referencesThe following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. All normative documents are subject to revision,
31、and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.IEC 81:1984, Tubular fluo
32、rescent lamps for general lighting service. IEC 400:1991, Lampholders for tubular fluorescent lamps and starterholders. IEC 598, Luminaires. IEC 695-2-1:1991, Fire hazard testing. Part 2: Test methods Section 1: Glow-wire test and guidance. IEC 901:1987, Single-capped fluorescent lamps Safety and pe
33、rformance requirements. IEC 921:1988, Ballasts for tubular fluorescent lamps. Performance requirements. !ISO 4046:1978, Paper, board, pulp and related #ISO 2081:1986, Metallic coatings Electroplated coatings of zinc on iron or steel. ISO 2093:1986, Electroplated coatings of tin Specification and tes
34、t methods.$3 Definitions3.1 startera device, other than a main switch, which closes or opens the pre-heating circuit of a fluorescent lamp for the purpose of starting the lamp3.2 glow-startera starter which depends for its operation on a glow discharge in a gaseous atmosphere3.3 non-reclosure voltag
35、ea reduced voltage at which the starter contacts must not reclose after operation at the test voltage specified for testing the speed of operation3.4 deactivated lampa lamp in which one or both filaments are deprived of emitting material, but neither of which is broken3.5 glow-starters with operatin
36、g time limitationa glow-starter which prevents prolonged attempts to start lamps which refuse to start, e.g. lamps with deactivated electrodesthe following types can be distinguisheda) starters which are non-resettable (one shot);b) starters with a manual reset;c) starters with an automatic reset, b
37、y actuating the main switch or other intended actions.4 General requirementsStarters shall be so designed and constructed that in normal use their operation is without danger to the user or surroundings. In general, compliance is checked by carrying out all the tests specified.5 General requirements
38、 for tests5.1 Requirements for type tests only are included.5.2 Unless otherwise specified, the tests shall be made at an ambient temperature of 25 C 5 C.5.3 The tests shall be carried out in the order of the clauses. BSI 2007 5items Vocabulary.“#ISO 1456:2003, Metallic coatings Electrodeposited coa
39、tings of nickel plus chromium and of copper plus nickel plus chromium.$6 Marking6.1 Starters shall be provided with durable and legible marking as follows:EN 60155:1995a) manufacturers or responsible vendors name, or trade mark;b) type or catalogue reference;c) lamp(s) for which the starter is inten
40、ded.If this requirement is marked in the form of a lamp wattage range, the marking shall:i) either include all the standardized wattages within that range in IEC 81 or 901; orii) indicate departures from that range either on the packaging material or in catalogues published by the manufacturer;d) te
41、mperature range for which the starter is intended to be used, if applicable.6.2 Other useful indications, for example the circuit for which the starter is intended and, in some cases, the rated voltage of the starter, shall either be marked on the starter, or be referred to in the manufacturers publ
42、ications.If applicable, the information shall be given that the starter is equipped with means of operating time limitation.6.3 Marking shall be indelible and easily legible. It shall comply with the requirements of 7.11.7 Requirements and tests for safety7.1 Type test quantityThe type test quantity
43、 shall consist of five starters to be submitted to the tests specified in 7.3 to 7.11 and 7.12.1, and 10 capacitors to be submitted to the test specified in 7.12.2 and 7.12.3. In addition, for starters with operating time limitations, five starters shall be submitted to the test specified in 7.13.7.
44、2 Conditions of acceptanceThe type shall be considered as satisfying the requirements of this subclause if all five starters comply with the tests specified in 7.3 to 7.11 and in 7.12.1 and if applicable, 7.13, and if all 10 capacitors comply with the tests specified in 7.12.2 and 7.12.3.If any fail
45、ures occur during a test, that test and the preceding ones, which may have influenced the results of that test, are repeated on a further five starters, all of which shall then comply with the repeated tests.All 10 starter capacitors submitted to the tests specified in 7.12.2 and 7.12.3 shall pass t
46、he tests. If any failure occurs during these tests, they shall be 7.3 Protection against accidental electric shocksEnclosures for interchangeable starters shall ensure protection against electric shocks. Protection may be ensured either by an insulating enclosure, by an appropriate non-metallic lini
47、ng, or other means which prevent accidental contact between live parts and the enclosure.Compliance is checked by inspection.7.4 Insulation resistance under humidity conditionsImmediately after a humidity treatment of 24 h 2 in an atmosphere of 91 % to 95 % relative humidity, and an ambient temperat
48、ure between 20 C and 27 C maintained within limits of 1 C, the insulation resistance between live parts and the metal canister of the starter shall be not less than 2 M7 measured after 1 min at 500 V d.c. In the case of canisters of insulating material, they shall be covered by tinfoil and the prece
49、ding requirements shall be satisfied, the test being carried out between the foil and live parts.Before starting the humidity treatment, the starters shall be kept in an ambient temperature which does not differ from the temperature within the humidity test enclosure by more than C, for at least 4 h.7.5 Dielectric strengthImmediately after the insulation resistance test, the starter shall be subjected to and satisfactorily withstand for 1 min without breakdown a sinusoidal a.c. voltage of 1 500 V r.m.s. applied b