1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Connectors forelectronic equipment Tests and measurements Part 16-116: Mechanical testson contacts and terminatio
2、ns Test 16p: Torsional strength,fixed male tabsBS EN 60512-16-16:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSINational forewordThis British Standard is the UK implementation of EN 60512-16-16:2008.It is identical to IEC 60512-16-16:2008.The U
3、K participation in its preparation was entrusted to TechnicalCommittee EPL/48, Electromechanical components and mechanical struc-tures for electronic equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to includ
4、e all the necessary provisionsof a contract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 55920 4ICS 31.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy an
5、d Strategy Committee on Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60512-16-16:200831 January 2009Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD EN 60512-16-16 NORME EUROPENNE EUROPISCHE NO
6、RM September 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by a
7、ny means reserved worldwide for CENELEC members. Ref. No. EN 60512-16-16:2008 E ICS 31.220.10 English version Connectors for electronic equipment - Tests and measurements - Part 16-16: Mechanical tests on contacts and terminations - Test 16p: Torsional strength, fixed male tabs (IEC 60512-16-16:2008
8、) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 16-16: Essais mcaniques des contacts et des sorties - Essai 16p: Rsistance la torsion des languettes fixes (CEI 60512-16-16:2008) Steckverbinder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 16-16: Mechanische P
9、rfungen an Kontakten und Anschlssen - Prfung 16p: Verdrehfestigkeit von Flachsteckern (IEC 60512-16-16:2008) This European Standard was approved by CENELEC on 2008-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Euro
10、pean Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (Eng
11、lish, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria,
12、 Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licen
13、sed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSIEN 60512-16-16:2008 - 2 - Foreword The text of document 48B/1890/FDIS, future edition 1 of IEC 60512-16-16, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structur
14、es for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-16-16 on 2008-08-01. This standard is to be read in conjunction with EN 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed:
15、latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-08-01 Annex ZA has been added by CENELEC. _ Endo
16、rsement notice The text of the International Standard IEC 60512-16-16:2008 was approved by CENELEC as a European Standard without any modification. _ Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSI- 3 - EN 60512-16-16:2008 Annex ZA (normative) Norm
17、ative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced
18、document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 - 1)Connectors for electronic equipment - Tests and measurements - Part 1-1:
19、General examination - Test 1a: Visual examination EN 60512-1-1 2002 2)1)Undated reference. 2)Valid edition at date of issue. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSI 4 60512-16-16 IEC:2008 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUR
20、EMENTS Part 16-16: Mechanical tests on contacts and terminations Test 16p: Torsional strength, fixed male tabs 1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing electomechanical components within the scope of IEC technical committee 48. It may
21、also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified torque. If so specified in the detail specification, forces other t
22、han torsional may be applied. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appli
23、es. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparations 3.1 Preparation of specimen The specimens shall consist of a connector fitted with one or more male tabs. It may be wired if so specified in the deta
24、il specification. Any preconditioning given in the detail specification shall be applied. Three such specimens shall be prepared. 3.2 Equipment A universal testing machine suitable for the test procedure detailed in Clause 4 shall be required, equipped with all relevant test fixtures needed to hold
25、the specimen under test. BS EN 60512-16-16:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSI60512-16-16 IEC:2008 5 3.3 Mounting If mounting of the specimen is appropriate, it shall be as specified in the component detail specification. P 0,8L L S
26、cDpt T DpfIEC 1008/08 Key L Length of the contact under test, tip to component surface T Torque P Plane of application of torque DptPermanent displacement of the tip of the specimen (tab) DpfPermanent displacement of the tip of the specimen (fixing) ScSurface of the component Figure 1 Application of
27、 the torque 4 Test method 4.1 General A torque T shall be applied to the fixed tab in the direction specified in Figure 1. The torque shall be steadily increased from zero to that specified in the component specification. This torque shall be maintained for 1 minute. The torque shall be removed, and
28、 the (permanent) displacement of the tab shall be measured. Permanent displacement is defined as the difference between the initial position of the tab before application of any torque and its position after all torque is removed. At least 10 tabs shall be selected at random from the 3 specimens pro
29、vided that at least one tab shall be near the periphery, and one, at or near, the centre of the connector insert or BS EN 60512-16-16:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSI 6 60512-16-16 IEC:2008 housing. For inserts or housings having
30、 3 or less tabs, all tabs shall be tested. This shall be repeated, on an adjacent (new) tab, with the torque being applied in the opposite direction. 4.2 Measurements and requirements 4.2.1 Before testing Visual examination according to IEC 60512-1-1 shall be carried out. There shall be no defects w
31、hich would impair the validity of the test. 4.2.2 During testing The displacement and permanent displacement of the component, measured at the plane of application of the torque shall be measured. NOTE In the case of a tab being made from a highly resilient material (e.g. spring steel or beryllium c
32、opper) the displacement may be large whilst the permanent displacement is negligible. In the case of a tab being held in a plastic material, recovery of displacement of that material may take place over a period. Furthermore, as the properties of such plastic materials may vary considerably with tem
33、perature, these tests will normally be done at laboratory temperatures (NTP), and any deviation from this should be given in the relevant detail specification. The permanent displacement shall not exceed any value given in the component detail specification. 4.2.3 After testing Visual examination ac
34、cording to IEC 60512-1-1 shall be carried out. There shall be no defects that would impair the normal functioning of the connector. This shall be judged by a mating test with its counterpart. 5 Details to be specified When this test is required by a detail specification, the following shall be given
35、 therein: a) whether preconditioning is required; b) whether the specimen is to be wired, and if so, details of this; c) whether special mounting of the specimen is required; d) torque to be applied and orientation with respect to the tab; e) allowable permanent set; f) number of specimens to be tes
36、ted shall be 3 unless otherwise specified; g) any deviation from the standard test method. _ BS EN 60512-16-16:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSIThis page deliberately left blankLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS
37、, 26/05/2009 07:25, Uncontrolled Copy, (c) BSIBSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worl
38、dwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the qual
39、ity of our products andservices. We would be grateful if anyone finding an inaccuracy orambiguity while using this British Standard would inform the Secretary ofthe technical committee responsible, the identity of which can be foundon the inside front cover.Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 89
40、96 7400BSI offers members an individual updating service called PLUS whichensures that subscribers automatically receive the latest editions ofstandards.Buying standardsOrders for all BSI, international and foreign standards publicationsshould be addressed to BSI Customer Services.Tel: +44 (0)20 899
41、6 9001 Fax: +44 (0)20 8996 7001Email: You may also buy directly using a debit/credit card from the BSI Shopon the website response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards, unless otherwise requeste
42、d.Information on standardsBSI provides a wide range of information on national, European andinternational standards through its Library.Various BSI electronic information services are also available which givedetails on all its products and services. Contact the Information Centre. Tel: +44 (0)20 89
43、96 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standardsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact MembershipAdministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 899
44、6 7001 Email: Information regarding online access to British Standards via BritishStandards Online can be found at information about BSI is available on the BSI website CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of thepublications of the internati
45、onal standardization bodies. Except as permitted under theCopyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrievalsystem or transmitted in any form or by any means electronic, photocopying, recording orotherwise without prior written permission from BSI. This does
46、not preclude the free use, in the course of implementing the standard of necessarydetails such as symbols, and size, type or grade designations. If these details are to be used forany other purpose than implementation then the prior written permission of BSI must beobtained. Details and advice can be obtained from the Copyright & Licensing Manager.Tel: +44 (0)20 8996 7070 Email: WB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 2Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 26/05/2009 07:25, Uncontrolled Copy, (c) BSI