BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf

上传人:registerpick115 文档编号:575804 上传时间:2018-12-13 格式:PDF 页数:8 大小:462.14KB
下载 相关 举报
BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf_第1页
第1页 / 共8页
BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf_第2页
第2页 / 共8页
BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf_第3页
第3页 / 共8页
BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf_第4页
第4页 / 共8页
BS EN 60512-16-2-2008 Connectors for electronic equipment - Tests and measurements - Part 16-2 Mechanical tests on contacts nand terminations — Test 16b Restricted nentry《电子设备用连接器 .pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARDBS EN 60512-16-2: 2008Connectors for electronic equipment Tests and measurements Part 16-2: Mechanical tests on contacts and terminations Test 16b: Restricted entryICS 31.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g

2、40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60512-16-2:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 August 2008 BSI 2008ISBN 978 0 580 55908 2National forewordThis British Stand

3、ard is the UK implementation of EN 60512-16-2:2008. It is identical to IEC 60512-16-2:2008. The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represented on this

4、 committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda iss

5、ued since publicationDate CommentsEUROPEAN STANDARD EN 60512-16-2 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Sta

6、ssart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-16-2:2008 E ICS 31.220.10 English version Connectors for electronic equipment - Tests and measurements - Part 16-2: Mechanical tests on contact

7、s and terminations - Test 16b: Restricted entry (IEC 60512-16-2:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 16-2: Essais mcaniques des contacts et des sorties - Essai 16b: Entre restreinte (CEI 60512-16-2:2008) Steckverbinder fr elektronische Einrichtungen - Mess- und

8、 Prfverfahren - Teil 16-2: Mechanische Prfungen an Kontakten und Anschlssen - Prfung 16b: Steckffnung (IEC 60512-16-2:2008) This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for g

9、iving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three officia

10、l versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committ

11、ees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United

12、 Kingdom. Foreword The text of document 48B/1878/FDIS, future edition 1 of IEC 60512-16-2, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 6

13、0512-16-2 on 2008-07-01. This standard is to be read in conjunction with EN 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national stan

14、dard or by endorsement (dop) 2009-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60512-16-2:2008 was approved by CENELEC as a European

15、Standard without any modification. _ 2 BS EN 60512-16-2:2008CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 16-2: Mechanical tests on contacts and terminations Test 16b: Restricted entry 1 Scope and object This part of IEC 60512, when required by the detail specification, is used for

16、 testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to assess the effectiveness of the means by which an oversize male contact, or ot

17、her similar object, is prevented from entering the equivalent female contact. NOTE Although this test is particularly applicable to cylindrical contacts, the use for contacts with other geometries is not excluded. In which case, the detail specification should contain sufficient detail, given under

18、5.e), to enable the test to be done. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments

19、) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparations 3.1 Preparation of specimen The specimen shall consist of a connector with its terminations, and may be wired if so specified in the detail sp

20、ecification. Any preconditioning given in the component detail specification shall be applied. If lubricant is required by the detail specification, this shall be applied in the manner so specified. 3.2 Equipment A test gauge, as specified in the detail specification, shall be provided. 3.3 Pre-cond

21、itioning Any pre-conditioning of the samples required by the applicable detail specification shall be applied. 3.4 Mounting If mounting of the specimen is necessary, it shall be as specified in the detail specification. 3 BS EN 60512-16-2:20084 Test method 4.1 Procedure Attempts shall be made to ent

22、er the specified test gauge into the connector under test. If a maximum force to achieve this is given in detail specification, this shall not be exceeded. If no such force is specified, the maximum force deemed appropriate by the testing laboratory shall be applied. The value of this force shall be

23、 recorded. 4.2 Measurements and requirements 4.2.1 Before testing Visual examination according to IEC 60512-1-1 shall be carried out. There shall be no defects, which would impair the validity of the test. 4.2.2 During testing If it is possible to cause the test gauge to enter the connector under te

24、st, such force shall be measured. NOTE It is recommended that electrical contact between the test probe and the contact under test be one criterion of entry. 4.2.3 After testing Visual examination according to IEC 60512-1-1 shall be carried out. Details shall be specified. 5 Details to be specified

25、When this test is required by a detail specification, the following shall be given therein: a) whether preconditioning is required; b) wiring of the specimen; c) whether special mounting of the specimen is required; d) maximum force to be applied may be specified; e) if the contact is not cylindrica

26、l, sufficient details of equipment procedure, and measurements, for the test to be done; f) any deviation from the standard test method. _ 4 BS EN 60512-16-2:2008Annex ZA(normative) Normative references to international publications with their corresponding European publications The following refere

27、nced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common mo

28、difications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 -1)Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 20022)1)Undated reference. 2)Valid edition at date o

29、f issue. 5 BS EN 60512-16-2:2008BS EN 60512-16-2: 2008BSI Group Headquarters389 Chiswick High Road,London W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards Institution (BSI)BSI is the independent national body responsible for preparing British Standards. It presents the UK view on stand

30、ards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of

31、our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996

32、 7400BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996

33、9001 Fax: +44 (0)20 8996 7001 Email: You may also buy directly using a debit/credit card from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise

34、requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and serv

35、ices. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership A

36、dministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via British Standards Online can be found at http:/ information about BSI is available on the BSI website at http:/.CopyrightCopyright subsists in all BSI publications. BS

37、I also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying

38、, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070 Email:

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1