1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationAutomatic electrical controls for household and similar usePart 2-7: Particular requirements for timers and time switchesBS EN 60730-2-7:2010Licensed Copy: Wang Bin, ISO/EXCHANGE
2、 CHINA STANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSINational forewordThis British Standard is the UK implementation of EN 60730-2-7:2010. It was derived from IEC 60730-2-7:2008. It supersedes BS EN 60730-2-7:1992, which will be withdrawn on 1 October 2013.The CENELEC common modifications h
3、ave been implemented at the appropriate places in the text and are indicated by tags (e.g. ).The UK participation in its preparation was entrusted to Technical CommitteeCPL/72, Electrical control devices for household equipment and appliances. A list of organizations represented on this committee ca
4、n be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 53309 9 ICS 39.040.99; 97.120Compliance with a British Standard cannot confer immunity from leg
5、al obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60730-2-7:2010Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 0
6、8:37, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD EN 60730-2-7 NORME EUROPENNE EUROPISCHE NORM October 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marni
7、x 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60730-2-7:2010 E ICS 97.120 Supersedes EN 60730-2-7:1991 + corr. Mar.2001 + A1:1997 + corr. Mar.2001 + A11:1994 + corr. Mar.2001 + A12:1993 + corr. Mar.2
8、001 + A13:2003 + A14:2003English version Automatic electrical controls for household and similar use - Part 2-7: Particular requirements for timers and time switches (IEC 60730-2-7:2008, modified) Dispositifs de commande lectrique automatiques usage domestique et analogue - Partie 2-7: Rgles particu
9、lires pour les minuteries et les minuteries cycliques (CEI 60730-2-7:2008, modifie) Automatische elektrische Regel- und Steuergerte fr den Hausgebrauch und hnliche Anwendungen - Teil 2-7: Besondere Anforderungen an Zeitsteuergerte und Schaltuhren (IEC 60730-2-7:2008, modifiziert) This European Stand
10、ard was approved by CENELEC on 2010-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerni
11、ng such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its
12、 own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, I
13、reland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSIForeword The text of the
14、International Standard IEC 60730-2-7:2008, prepared by IEC TC 72, Automatic controls for household use, together with the common modifications prepared by the Technical Committee CENELEC TC 72, Automatic controls for household use, was submitted to the CENELEC Unique Acceptance Procedure and was app
15、roved as EN 60730-2-1 on 2010-10-01. This document supersedes EN 60730-2-7:1991 + A1:1997 + A11:1994 + A12:1993 + A13:2003 + A14:2003. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible f
16、or identifying any or all such patent rights. The following dates are fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-10-01 latest date by which the national standards conflicting with the EN hav
17、e to be withdrawn (dow) 2013-10-01 This Part 2-7 is to be used in conjunction with EN 60730-1:2000, Automatic electrical controls for household and similar use Part 1: General requirements, and any subsequent amendments. This European Standard has been prepared under a mandate given to CENELEC by th
18、e European Commission and the European Free Trade Association and covers essential requirements of EC Directive 2004/108/EC. See Annex ZZ. Annexes ZA and ZZ have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60730-2-7:2008 was approved by CENELEC as a Europea
19、n Standard with agreed common modifications. BS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 2 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSICONTENTS 1 Scope and normative references 4 2 Definitions 5 3 General requirements.6 4 General notes on tests .6
20、 5 Rating 6 6 Classification7 7 Information . 88 Protection against electric shock 99 Provision for protective earthing . 910 Terminals and terminations 911 Constructional requirements. 912 Moisture and dust resistance10 13 Electric strength and insulation resistance10 14 Heating 10 15 Manufacturing
21、 deviation and drift11 16 Environmental stress 11 17 Endurance11 18 Mechanical strength .16 19 Threaded parts and connections.16 20 Creepage distances, clearances and distances through solid insulation .16 21 Fire hazard testing .16 22 Resistance to corrosion 17 23 Electromagnetic compatibility (EMC
22、) requirements emission .17 24 Components .17 25 Normal operation17 26 Electromagnetic compatibility (EMC) requirements immunity .17 27 Abnormal operation 17 28 Guidance on the use of electronic disconnection 17 Annex H (normative) Requirements for electronic controls .18 Annex AA (normative) Number
23、 of cycles, automatic and manual action20 Table AA.1 Values for free standing, independently mounted and in-line cord timers and time switchesa.20 Annex ZA (normative) Normative references to international publications with their corresponding European publications 21 Annex ZZ (informative) Coverage
24、 of Essential Requirements of EC Directives. 22BS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 3 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSIAUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE Part 2-7: Particular requirements for timers and t
25、ime switches 1 Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Replacement: In general, this part of IEC 60730 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a c
26、ombination thereof, including heating, air conditioning and similar applications. This standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outlets. This standard does not a
27、pply to time-delay switches (TDS) within the scope of IEC 60669-2-31). Throughout this standard, the word “timers” means timers and time switches, unless the type is specifically mentioned. Devices which only indicate time or passage of time are not included. This standard does not apply to multi-fu
28、nctional controls having an integrated timing function which is not capable of being tested as a separate timing device. 1.1.1 This standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of automatic electrical
29、 control devices used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc. Timers for equipme
30、nt not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard is also applicable to timers for appliances within the scope of I
31、EC 60335-1. This standard does not apply to timers designed exclusively for industrial applications. Throughout this standard, the word “equipment“ means “appliance and equipment“. 1.1.2 This standard applies to automatic electrical control devices, mechanically, electromechanically, electrically or
32、 electronically operated, responsive to or controlling parameters such as temperature, pressure, passage or time, humidity, light, electrostatic effect, flow or liquid level. _ 1)IEC 60669-2-3:2006, Switches for household and similar fixed electrical installations Part 2-3: Particular requirements T
33、ime-delay switches (TDS) BS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 4 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSI1.1.3 This standard applies to automatic electrical control devices serving the starting of small motors that are used principally i
34、n appliances and apparatus for household and similar purposes. Such control devices may be built into or be separate from the motor. 1.1.4 This standard applies to non-automatic control devices when such are associated with automatic control devices. 1.2 Replacement: This standard applies to control
35、s with a rated voltage not exceeding 690 V and a rated current not exceeding 63 A. 1.3 Replacement: This standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. If a re
36、sponse value is of significant purpose for the safety of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply. 1.4 Replacement: This standard applies also to timers incorporating electronic devices, requirements
37、for which are contained in Annex H. 1.5 Normative references This subclause of Part 1 applies except as follows: Addition: IEC 60669-1:1998, Switches for household and similar fixed-electrical installations Part 1: General requirements 2)Amendment 1 (1999) Amendment 2 (2006) IEC 61010-1, Safety requ
38、irements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements 2 Definitions This clause of Part 1 is applicable except as follows: 2.3 Definitions relating to the function of controls Additional definition: 2.3.101 timing cycle program including all the
39、switching activities involved in a start-to-finish operation of a controlled appliance _ 2)There exists a consolidated edition 3.2 (2007) that includes edition 3 and its Amendments 1 and 2. BS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 5 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011
40、08:37, Uncontrolled Copy, (c) BSI2.5 Definitions of types of control according to construction Additional definitions: 2.5.101 plug-in timer timer or time switch designed for direct plug-in to a socket-outlet NOTE The plug-in timer is equipped with conductor blades, pins or other means, protruding f
41、rom the enclosure of the control or the control body itself, to match the dimensional parameters of the socket-outlet to which the control will be connected. 2.5.102 TV timer control for television equipment that can be set by the user, switching very high inrush currents of a very short duration ge
42、nerated by electrical power supply components and associated electronic component parts with various electrical characteristics NOTE Examples are power transformers, electronic tube filaments, large electric capacitors and others in television receivers, radio and video products. 2.5.103 synchronous
43、 timer timer or a time switch in which the transmission is effected by a device that is time-based on the frequency of the power supply for the prime mover or the load 2.5.104 hand-wound timer timer or time switch in which the transmission is provided by actuation 3 General requirements This clause
44、of Part 1 is applicable. 4 General notes on tests This clause of Part 1 is applicable except as follows: 4.1.4 Addition: 4.3.2.1 Addition: 5 Rating This clause of Part 1 is applicable. Text deleted Text deletedBS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 6 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA ST
45、ANDARDS, 19/07/2011 08:37, Uncontrolled Copy, (c) BSI6 Classification This clause of Part 1 is applicable except as follows: 6.3 According to their purpose 6.3.6 Additional subclause: 6.3.6.101 TV timer; 6.4 According to features of automatic action 6.4.3 Additional subclauses: 6.4.3.101 a timing ac
46、tion which automatically resets upon loss of the electrical supply (Type 1.Q or 2.Q); 6.4.3.102 a timing action which is interrupted upon loss of the electrical supply and resumes at the point of interruption upon restoration of the electrical supply (Type 1.R or 2.R); 6.4.3.103 a timing action of a
47、 time switch which, after interruption of the electrical supply for any interval up to the declared period of power reserve, resumes its intended operating sequence as if no interruption of the supply has occurred (Type 1.S or 2.S); 6.4.3.104 a timing action with a declared running accuracy in an am
48、bient temperature of 20 C to 25 C (Type 1.T or 2.T); 6.4.3.105 a timing action in which the difference between set time and actual switching time does not exceed the declared amount (Type 1.U or 2.U). 6.5 According to the degree of protection and control pollution degree Additional subclause: 6.5.10
49、1 According to declared industrial environmental conditions (see IEC 61010-1): 6.10 According to number of cycles of actuation (M) for each manual actuation Additional subclauses: 6.10.101 500 cycles; 6.10.102 2 500 cycles; 6.10.103 5 000 cycles. 6.15 According to construction Additional subclause: 6.15.101 plug-in timer. Text deletedBS EN 60730-2-7:2010EN 60730-2-7:2010 (E) 7 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 19/07/2011 08:37, Uncontrol