1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectric and optical fibre cables Test methods for non-metallic materialsPart 505: Mechanical tests Elongation at low temperature for insulations and sheathsBS EN 60811-505:2012N
2、ational forewordThis British Standard is the UK implementation of EN 60811-505:2012. It isidentical to IEC 60811-505:2012. In the UK, the relationship between the supersessions of BS EN 60811 seriescan be summarized as follows.Superseded standards are withdrawnThe UK participation in its preparation
3、 was entrusted by Technical CommitteeGEL/20, Electric cables, to Subcommittee GEL/20/17, Electric Cables - Lowvoltage.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontrac
4、t. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 65327 8ICS 29.035.01; 29.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under t
5、he authority of the StandardsPolicy and Strategy Committee on 31 July 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60811-505:2012BS EN 60811-100 together with Supersedes - -201, -202, -203, -501 BS EN 60811-1-1:1995 -301, -302, -411, -601, -602, -603, -604
6、 BS EN 60811-5-1:2000 -401, -412 BS EN 60811-1-2:1995 -402, -502, -503, -606 BS EN 60811-1-3:1995 -403, -404, -507 BS EN 60811-2-1:1998 -405, -409 BS EN 60811-3-2:1995 -406, -511, -605, -607 BS EN 60811-4-1:2004 -407, -408, -410, -510, -512, -513 BS EN 60811-4-2:2004 -504, -505, -506 BS EN 60811-1-4
7、:1995 -508, -509 BS EN 60811-3-1:1995EUROPEAN STANDARD EN 60811-505 NORME EUROPENNE EUROPISCHE NORM June 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Mar
8、nix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60811-505:2012 E ICS 29.035.01; 29.060.20 Supersedes EN 60811-1-4:1995 (partially) + A2:2001 (partially)English version Electric and optical fibre cabl
9、es - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths (IEC 60811-505:2012) Cbles lectriques et fibres optiques - Mthodes dessai pour les matriaux non-mtalliques - Partie 505: Essais mcaniques - Essai dallongement basse t
10、emprature pour les enveloppes isolantes et les gaines (CEI 60811-505:2012) Kabel, isolierte Leitungen und Glasfaserkabel - Prfverfahren fr nichtmetallene Werkstoffe - Teil 505: Mechanische Prfungen - Dehnungsprfungen bei niedriger Temperatur fr Isolierhllen und Mntel (IEC 60811-505:2012) This Europe
11、an Standard was approved by CENELEC on 2012-04-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
12、concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENEL
13、EC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany,
14、 Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. EN 60811-505:2012 - 2 - Foreword The text of document 20/1301/FDIS, future edition 1 of
15、IEC 60811-505, prepared by IEC/TC 20 “Electric cables“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60811-505:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standar
16、d or by endorsement (dop) 2013-01-17 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2015-04-17 This document supersedes 8.3 and 8.4 of EN 60811-1-4:1995 + A2:2001 (partially). Full details of the replacements are shown in Annex A of EN 60811-100:
17、2012. There are no technical changes with respect to EN 60811-1-4:1995, but see the Foreword to EN 60811-100. This standard is to be read in conjunction with EN 60811-100. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC an
18、d/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Stan
19、dard IEC 60811-505:2012 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 60811-1-4:1985 NOTE Harmonized as EN 60811-1-4:1995 (not modified). BS EN 60811-505:2012- 3
20、- EN 60811-505:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only t
21、he edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC
22、60811-100 2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General EN 60811-100 2012 IEC 60811-501 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties
23、of insulating and sheathing compounds EN 60811-501 - IEC 60811-504 - Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths EN 60811-504 - BS EN 60811-505:2012 2 60811-505 IEC:2012 CONTENT
24、S INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 6 4 Test method . 6 4.1 General . 6 4.2 Elongation test at low temperature for insulation . 7 4.2.1 Sampling . 7 4.2.2 Preparation of test pieces 7 4.2.3 Apparatus 7 4.2.4 Procedure and test conditions . 8 4.2.5 Eval
25、uation of results 8 4.3 Elongation test at low temperature for sheaths 8 4.3.1 Sampling . 8 4.3.2 Preparation of test pieces 8 4.3.3 Apparatus 9 4.3.4 Procedure and test conditions . 9 4.3.5 Evaluation of results 9 5 Test report 9 Bibliography 11 Figure 1 Dumb-bell test piece 10 Figure 2 Small dumb-
26、bell test piece . 10 BS EN 60811-505:201260811-505 IEC:2012 5 INTRODUCTION The IEC 60811 series specifies the test methods to be used for testing non-metallic materials of all types of cables. These test methods are intended to be referenced in standards for cable construction and for cable material
27、s. NOTE 1 Non-metallic materials are typically used for insulating, sheathing, bedding, filling or taping within cables. NOTE 2 These test methods are accepted as basic and fundamental and have been developed and used over many years principally for the materials in all energy cables. They have also
28、 been widely accepted and used for other cables, in particular optical fibre cables, communication and control cables and cables for ships and offshore applications. BS EN 60811-505:2012 6 60811-505 IEC:2012 ELECTRIC AND OPTICAL FIBRE CABLES TEST METHODS FOR NON-METALLIC MATERIALS Part 505: Mechanic
29、al tests Elongation at low temperature for insulations and sheaths 1 Scope This Part 505 of IEC 60811 gives the procedure for performing elongation tests at low temperature on extruded insulations and sheaths. 2 Normative references The following documents, in whole or in part, are normatively refer
30、enced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60811-100:2012, Electric and optical fibre cables Test methods for non
31、-metallic materials Part 100: GeneralIEC 60811-501, Electric and optical fibre cables Test methods for non-metallic materials Part 501: Mechanical tests Tests for determining the mechanical properties of insulating and sheathing compoundsIEC 60811-504, Electric and optical fibre cables Test methods
32、for non-metallic materials Part 504: Mechanical tests Bending tests at low temperature for insulation and sheaths 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60811-100 apply. 4 Test method 4.1 General This part of IEC 60811 shall be used in conju
33、nction with IEC 60811-100. All the tests shall be carried out not less than 16 h after the extrusion of the insulating or sheathing compounds. Tests shall be carried out at the temperature specified in the relevant cable standard. For tests on insulation, the test is intended for insulated conductor
34、s of circular cross-section having an external diameter greater than 12,5 mm and for sector-shaped cores large enough to prepare dumb-bells. Where it is not possible to prepare dumb-bells, a bending test suitable for testing the performance of cores of smaller diameter is described in IEC 60811-504.
35、 This test is intended for the sheaths of cables not subjected to the bend test as specified in IEC 60811-504. It is intended for cables with an overall diameter over 12,5 mm, or for flat cables having, a major axis dimension over 12,5 mm. Cables with an overall diameter up to BS EN 60811-505:201260
36、811-505 IEC:2012 7 and including 12,5 mm shall be subjected to the low temperature bending test detailed in IEC 60811-504. 4.2 Elongation test at low temperature for insulation 4.2.1 Sampling Each core to be tested shall be represented by two samples of suitable length. 4.2.2 Preparation of test pie
37、ces After all covering (including outer semi-conducting layer, if any) has been removed, the insulation shall be cut open in the direction of the axis, after which the conductor and the internal semi-conducting layer, if any, shall be removed. The insulation need not be ground or cut if the inner an
38、d outer surfaces are smooth, and its mean specified thickness does not exceed 2,0 mm. Samples having a thickness exceeding this limit, or samples having imprints or ridges on the inner side, shall be ground or cut to obtain two parallel and smooth surfaces, and a thickness which does not exceed 2,0
39、mm. The minimum thickness after grinding or cutting shall be 0,8 mm but if the original thickness of the insulation does not allow it, then 0,6 mm shall be permitted as the minimum thickness. Grinding and cutting shall be carefully carried out to avoid undue heating and mechanical stresses in the in
40、sulation. All strips shall be conditioned at ambient temperature for at least 3 h. After this preparation, two dumb-bells from each sample in accordance with Figure 1, or if necessary Figure 2, shall be punched in the direction of the axis of each sample; if possible, two dumb-bells shall be punched
41、 side by side. For sector-shaped cores, the dumb-bells shall be punched out of the rounded “back” of the core. If an apparatus is used which allows the direct measurement of the distance between the marker lines during the test, the dumb-bells shall be marked in accordance with IEC 60811-501. 4.2.3
42、Apparatus The test may be carried out on a machine provided with a cooling device or on a machine installed in a cooling chamber. Using a liquid as the refrigerant, the conditioning time shall be not less than 10 min at the specified test temperature. When cooling in air, the conditioning time for c
43、ooling the apparatus and test piece together shall be at least 4 h. If the apparatus has been pre-cooled, this period may be reduced to 2 h, and if the apparatus and test piece have been pre-cooled, the conditioning time after the test piece has been fixed in the apparatus shall be not less than 1 h
44、. If a liquid mixture is used for cooling, it shall not impair the insulating or sheathing material. An apparatus which allows direct measurement of the distance between the marker lines during the elongation test is preferred, but it is also permissible to use an apparatus with which the displaceme
45、nt between the grips can be measured. BS EN 60811-505:2012 8 60811-505 IEC:2012 4.2.4 Procedure and test conditions The grips of the tensile apparatus shall be of a non-self-tightening type. In both pre-cooled grips, the dumb-bell shall be clamped over the same length. The free length between the gr
46、ips shall be about 30 mm for both types of dumb-bells if the direct measurement of the distance between the marker lines is to be made during the test. If the displacement of the grips is to be measured, the free length between the grips shall be (30 0,5) mm for the dumb-bell in accordance with Figu
47、re 1, and (22 0,5) mm for the dumb-bell in accordance with Figure 2. The speed of separation of the grips of the tensile machine shall be (25 5) mm/min. The test temperature shall be as specified for the type of compound in the standard for the type of cable. The elongation shall be determined by me
48、asuring the distance between the marker lines, if possible, or between the grips at the moment of the rupture. 4.2.5 Evaluation of results For calculating the elongation, the increase of the distance between the marker lines shall be related to the initial distance of 20 mm (or 10 mm if the dumb-bel
49、l in accordance with Figure 2, is used), and expressed as a percentage of this distance. If the alternative method of measuring the distance between the grips is used, the increase of this distance shall be related to the original distance, being 30 mm for the dumb-bell in accordance with Figure 1, and 22 mm for the dumb-bell according to Figure 2. When this method is used, the test piece shall be examined before being removed from the apparatus; if the test piece has partly s