1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Radio frequency and coaxial cable assemblies Part 2-1: Sectional specification for flexible coaxial cable assembl
2、iesBS EN 60966-2-1:2009National forewordThis British Standard is the UK implementation of EN 60966-2-1:2009. It isidentical to IEC 60966-2-1:2008. It supersedes BS EN 60966-2-1:2003 whichis withdrawn.The UK participation in its preparation was entrusted to Technical CommitteeEPL/46, Cables, wires an
3、d waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for
4、 its correct application. BSI 2009ISBN 978 0 580 61636 5ICS 33.120.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 September 2009Amendments issued since publi
5、cationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60966-2-1:2009EUROPEAN STANDARD EN 60966-2-1 NORME EUROPENNE EUROPISCHE NORM August 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Nor
6、mung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60966-2-1:2009 E ICS 33.120.10 Supersedes EN 60966-2-1:2003English version Radio frequency and coaxial cable assemb
7、lies - Part 2-1: Sectional specification for flexible coaxial cable assemblies (IEC 60966-2-1:2008) Ensembles de cordons coaxiaux et de cordons pour frquences radiolectriques - Partie 2-1: Spcification intermdiaire pour cordons coaxiaux souples (CEI 60966-2-1:2008) Konfektionierte Koaxial- und Hochf
8、requenzkabel - Teil 2-1: Rahmenspezifikation fr flexible konfektionierte Koaxialkabel (IEC 60966-2-1:2008) This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europe
9、an Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (Engli
10、sh, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, B
11、elgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 6
12、0966-2-1:2009EN 60966-2-1:2009 - 2 - Foreword The text of document 46/262/CDV, future edition 3 of IEC 60966-2-1, prepared by IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved
13、by CENELEC as EN 60966-2-1 on 2009-07-01. This European Standard supersedes EN 60966-2-1:2003. The major change with respect to EN 60966-2-1:2003 is a better definition of the tests to be performed. This sectional specification is to be read in conjunction with EN 60966-1:1999. It contains the same
14、clauses as that of EN 60966-1 and completes or amends them when required. When a clause of EN 60966-1 does not appear in this standard, it applies as it is in EN 60966-1. When this standard states “addition“, “modification“ or “replacement“, the relevant text in Part 1 is to be adapted accordingly.
15、The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-07-01 Annex ZA h
16、as been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60966-2-1:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 60966-2-1:2009- 3 - EN 60966-2-1:2009 Annex ZA (normative) Normative references to international publications with
17、 their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE W
18、hen an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60068-2-6 -1)Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) EN 60068-2-6 20082)IEC 60096-2 -1)Radio-frequency c
19、ables - Part 2: Relevant cable specifications - - IEC 60410 -1)Sampling plans and procedures for inspection by attributes - - IEC 60966-1 1999 Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods EN 60966-1 1999 IEC 61169 Series Radio-f
20、requency connectors EN 61169 Series IEC 61196 Series Coaxial communication cables EN 61196 Series IEC QC 001002 Series IEC quality assessment system for electronic components (IECQ) - Rules of procedure - - ISO 9000 -1)Quality management systems - Fundamentals and vocabulary EN ISO 9000 20052)1)Unda
21、ted reference. 2)Valid edition at date of issue. BS EN 60966-2-1:2009 2 60966-2-1 IEC:2008(E) CONTENTS 1 Scope.5 2 Normative references .5 3 Terms and definitions .5 4 Design and manufacturing requirements.6 4.1 Cable design and construction.6 4.2 Connector design and construction6 4.3 Outline and i
22、nterface dimensions.6 5 Workmanship, marking and packaging7 6 Quality assessment 8 7 Test methods General .8 8 Electrical tests8 9 Mechanical robustness tests.9 10 Environmental tests9 11 Specialized test methods11 12 Test schedules .11 Figure 1 Length definition of cable assemblies.7 Figure 2 Examp
23、le of a cable assembly.7 Figure 3 Preferred arrangement for the vibration test .9 Figure 4 Example production flow chart for a flexible cable assembly 14 Table 1 Grouping of tests for specification purposes 12 Table 2 Test schedule13 Table 3 Assignment of CQCs .15 BS EN 60966-2-1:200960966-2-1 IEC:2
24、008(E) 5 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES Part 2-1: Sectional specification for flexible coaxial cable assemblies 1 Scope This part of IEC 60966 is a sectional specification that relates to flexible coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). It estab
25、lishes uniform requirements for testing the electrical, mechanical and climatic properties of flexible cable assemblies composed of flexible coaxial cables and coaxial connectors. NOTE 1 For the purposes of this sectional specification, a cable assembly is always regarded as an integral unit. All sp
26、ecifications apply to the finished assembly and not to individual and non-assembled parts thereof. NOTE 2 This sectional specification should be supplemented with detail specifications giving additional details as required by the particular application. This application will not necessarily require
27、all tests. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-2-6,
28、Environmental testing Part 2-6: Tests Test Fc: Vibration (sinusoidal) IEC 60096-2, Radio-frequency cables Part 2: Relevant cable specifications IEC 60410, Sampling plans and procedures for inspection by attributes IEC 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specifi
29、cation General requirements and test methods IEC 61169 (all parts), Radio-frequency connectors IEC 61196 (all parts), Coaxial communication cables IEC QC 001002 (all parts), IEC Quality Assessment System for Electronic Components (IECQ) Rules of procedure ISO 9000, Quality management systems Fundame
30、ntals and vocabulary 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60966-1 apply. BS EN 60966-2-1:2009 6 60966-2-1 IEC:2008(E) 4 Design and manufacturing requirements Clause 4 of IEC 60966-1 is applicable except as follows: Replacement: 4.1 Cable d
31、esign and construction Cables should conform to IEC 60096-2 or IEC 61196. Where cable designs deviating from these publications are required, they shall comply with the requirements of the detail specification. If required, the manufacturer may use additional protective tubing or cable deviating fro
32、m IEC 61196, in order to comply with the requirements of the detail specification. The materials used in the cable shall be given as engineering information in the detail specification. 4.2 Connector design and construction Connectors should conform to IEC 61169. Where connector designs deviating fr
33、om IEC 61169 are required, the interface should conform to the relevant part of IEC 61169 where available and shall comply with the requirements of the detail specification. The materials used in the connector shall be given as engineering information in the detail specification. 4.3 Outline and int
34、erface dimensions The outline and interface dimensions shall be in accordance with the detail specification of the cable assembly. The length, unless otherwise specified in the detail specification, is defined as between the reference planes of the connectors. In case of right angle connectors, the
35、length applies to the axis of the connectors (see Figure 1). If not indicated in the detail specification, the length tolerance shall be 1 % for cables equal to, or longer than, 300 mm and 3 mm for cables shorter than 300 mm. BS EN 60966-2-1:200960966-2-1 IEC:2008(E) 7 Length IEC 1761/08 Figure 1 Le
36、ngth definition of cable assemblies 5 Workmanship, marking and packaging Clause 5 of IEC 60966-1 is applicable, except as follows. 5.2 Marking Addition: Cable assemblies made in accordance with this sectional specification comprise a section of cable and two connectors. When specified in the detail
37、specification, the assembly may additionally include markers for identification of the assembly and interconnecting ends. End caps and other accessories may also be specified (see Figure 2). NOTE Occasionally, the cable assembly will comprise only a cable and one connector. Flexible cable Connector
38、1 Marking end 1aIdentificationaConnector 2 Marking end 2aIEC 1762/08 a When specified. Figure 2 Example of a cable assembly BS EN 60966-2-1:2009 8 60966-2-1 IEC:2008(E) 6 Quality assessment Clause 6 of IEC 60966-1 applies. 7 Test methods General Clause 7 of IEC 60966-1 applies. 8 Electrical tests Cl
39、ause 8 of IEC 60966-1 is applicable except as follows: 8.1.4 Information to be given in the detail specification Addition: While the parameter return loss (Ar) is preferred, the reflection factor (r) or the VSWR (voltage standing wave ratio)may be specified where rA10rlog 20= and VSWR rr+=118.4 Inse
40、rtion loss stability Replacement: 8.4.1 Object To determine the change of insertion loss when the cable assembly is subjected to bending and twisting (separately). 8.4.2 Procedures 8.4.2.1 Bending The test is to be performed as in 8.6.2.1 of IEC 60966-1 by measurement of the insertion loss (not the
41、phase). 8.4.2.2 Twisting The test is to be performed as in 8.6.2.2 of IEC 60966-1 by measurement of the insertion loss (not the phase). BS EN 60966-2-1:200960966-2-1 IEC:2008(E) 9 8.4.4 Information to be given in the detail specification Replacement: The following information is to be given: a) dyna
42、mic bending radius of the cable (radius of the mandrel); b) whether method 1 or 2 is used for the bending test; c) test frequencies; d) maximum change of insertion loss. 9 Mechanical robustness tests Clause 9 of IEC 60966-1 applies. 10 Environmental tests Clause 10 of IEC 60966-1 is applicable excep
43、t as follows: 10.2 Vibration, bumps and shock Replacement : 10.2.1 Vibration 10.2.1.1 Procedure The tests shall be carried out in accordance with test Fc of IEC 60068-2-6. The vibration severity shall be chosen from D.2.1 of IEC 60966-1, unless otherwise indicated in the detail specification. Vibrat
44、ing plate FixedTo measuring instrumentation IEC 1763/08 Figure 3 Preferred arrangement for the vibration test BS EN 60966-2-1:2009 10 60966-2-1 IEC:2008(E) The preferred arrangement for the vibration test is described in Figure 3. The cable portion of the cable assembly shall be vibrated in each of
45、three perpendicular directions, one of which shall be parallel to the common axis of the connectors. The continuity of the inner and outer conductors shall be monitored during the test. 10.2.1.2 Requirements There shall be no evidence of cracking, breaking or loosening of parts of a component and th
46、ere shall be no current discontinuity in excess of 1 s. After the test, the insertion loss and return loss shall not exceed the specified limits. 10.2.1.3 Information to be given in the detail specification The following information is to be given: a) mounting and fixing details of the cable assembl
47、y; NOTE The length of the cable in relation to its diameter, between the mounting plate and the fixed plate is an important variable. The fixed plate should be rigid. b) profile and severity parameters for vibration. These should include duration, frequency and acceleration or displacement. 10.2.2 B
48、umps This test shall be specified, if necessary, in the detail specification. For the recommended severities, see D.2.2 of IEC 60966-1. 10.2.3 Shock This test shall be specified, if necessary, in the detail specification. For the recommended severities, see D.2.3 of IEC 60966-1. 10.3.1 Procedure Add
49、ition: The test severities indicated in D.2.4 of IEC 60966-1 are preferred. 10.4.1 Procedure Addition: See D.2.5 of IEC 60966-1 for test severities. 10.5.1 Procedure Addition: See D.2.6 of IEC 60966-1 for test severities. BS EN 60966-2-1:200960966-2-1 IEC:2008(E) 11 11 Specialized test methods Clause 11 of IEC 60966-1 applies. 12 Test schedules Clause 12 of IEC 60966-1 is applicable except as follows. Replacement: 12.1 General In addition to