BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf

上传人:cleanass300 文档编号:577006 上传时间:2018-12-13 格式:PDF 页数:28 大小:1.70MB
下载 相关 举报
BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf_第1页
第1页 / 共28页
BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf_第2页
第2页 / 共28页
BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf_第3页
第3页 / 共28页
BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf_第4页
第4页 / 共28页
BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf_第5页
第5页 / 共28页
亲,该文档总共28页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationRadio-frequency connectorsPart 19: Sectional specification Radio frequency coaxial connectors of type SSMBBS EN 61169-19:2011National forewordThis British Standard is the UK impl

2、ementation of EN 61169-19:2011. It is identical to IEC 61169-19:2011. It supersedes DD IEC/PAS 61169-19:2009,which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communicat

3、ion and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 64923 3 ICS 33.120.

4、30Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61169-19:2011E

5、UROPEAN STANDARD EN 61169-19 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC

6、 - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-19:2011 E ICS 33.120.30 English version Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial connectors of type SSMB (IEC 61169-19:2011) Connecteurs

7、 pour frquences radiolectriques - Partie 19: Spcification intermdiaire - Connecteurs coaxiaux pour frquences radiolectriques de type SSMB (CEI 61169-19:2011) Hochfrequenz-Steckverbinder - Teil 19: Rahmenspezifikation - Hochfrequenz-Koaxial-Steckverbinder des Typs SSMB (IEC 61169-19:2011) This Europe

8、an Standard was approved by CENELEC on 2011-03-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references

9、concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member

10、into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ic

11、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61169-19:2011EN 61169-19:2011 - 2 - Foreword The text of document 46F/138/CDV, future edition 1 of IEC 61169-1

12、9, prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-19 on 2011-03-03. Attention is drawn t

13、o the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by public

14、ation of an identical national standard or by endorsement (dop) 2011-12-03 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-03-03 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61169-19:2011 was a

15、pproved by CENELEC as a European Standard without any modification. _ BS EN 61169-19:2011- 3 - EN 61169-19:2011 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the applicat

16、ion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/

17、HD applies. Publication Year Title EN/HD Year IEC 61169-1 A1 A2 1992 1996 1997 Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods EN 61169-1 A1 A2 1994 1996 1997 BS EN 61169-19:2011 2 61169-19 IEC:2011 CONTENTS 1 Scope . 6 2 Normative references .

18、 6 3 Mating face and gauge information . 6 3.1 Dimensions General purpose connectors Grade 2 . 6 3.1.1 Connector with socket-centre contact 6 3.1.2 Connector with pin-centre contact 8 3.2 Gauges . 9 3.2.1 Gauge pins for socket-centre contact . 9 3.2.2 Test procedure 9 3.2.3 Gauge for outer contact o

19、f socket-centre contact . 10 3.2.4 Test procedure 10 3.3 Dimensions Standard test connectors Grade 0 11 3.3.1 Connector with socket-centre contact 11 3.3.2 Connector with pin-centre contact 12 4 Quality assessment procedure 13 4.1 General . 13 4.2 Rating and characteristics (see Clause 6 of IEC 6116

20、9-1) . 13 4.3 Test schedule and inspection requirements Acceptance tests . 15 4.3.1 Acceptance tests . 15 4.3.2 Periodic tests 16 4.4 Procedures 18 4.4.1 Quality conformance inspection . 18 4.4.2 Qualification approval and its maintenance 18 5 Instructions for preparation of detail specifications .

21、18 5.1 General . 18 5.2 Identification of the component 18 5.3 Performance 19 5.4 Marking, ordering information and related matters . 19 5.5 Selection of tests, test conditions and severities 19 5.6 Blank detail specification pro-forma for type SSMB connector . 20 Figure 1 Connector with socket-cent

22、re contact (for dimensions and notes, see Table 1) . 7 Figure 2 Connector with pin-centre contact (for dimensions and notes, see Table 2) . 8 Figure 3 Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) 9 Figure 4 Outer contact sizing and retention force gauges A and B (for

23、dimensions and notes, see Table 4) 10 Figure 5 Connector with socket-centre contact (for dimensions and notes, see Table 5) . 11 Figure 6 Connector with pin-centre contact (for dimensions and notes, see Table 6) . 12 Table 1 Dimensions of connector with socket-centre contact 7 Table 2 Dimensions of

24、connector with pin-centre contact . 8 Table 3 Dimensions of gauge pins for socket-centre contact 9 Table 4 Dimensions of gauge for outer contact 10 Table 5 Dimensions of connector with socket-centre contact 11 BS EN 61169-19:201161169-19 IEC:2011 3 Table 6 Dimensions of connector with pin-centre con

25、tact . 12 Table 7 Rating and characteristics . 13 Table 8 Acceptance tests . 15 Table 9 Periodic tests 16 BS EN 61169-19:2011 6 61169-19 IEC:2011 RADIO-FREQUENCY CONNECTORS Part 19: Sectional specification Radio frequency coaxial connectors of type SSMB 1 Scope The SSMB series connectors with charac

26、teristic impedance 50 are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cabl

27、es and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz. This sectional specification provides information and rules for preparation of detail specification of SSMB series R.F connectors together with the pro forma blank detail specification. It also p

28、rescribes mating face dimensions for grade 2 general purpose connectors, dimensional detail of grade 0 standard test connectors, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF connectors. This specification indicates recomme

29、nded performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated re

30、ferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods1Amendment 1 (1996) Amendment 2 (19

31、97) 3 Mating face and gauge information 3.1 Dimensions General purpose connectors Grade 2 3.1.1 Connector with socket-centre contact All non-dimensioned pictorial configurations are for reference purpose only. _ 1There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Ame

32、ndment 1:1996 and its Amendment 2:1997. BS EN 61169-19:201161169-19 IEC:2011 7 Note 1Note 4Note 3jihfedcgab (Note2)IEC 058/11Figure 1 Connector with socket-centre contact (for dimensions and notes, see Table 1) Table 1 Dimensions of connector with socket-centre contact Ref. mm Min. Max. a 2,74 - b -

33、 c - 1,34 d - 1,78 e 0,84 - f 0,84 - g 2,11 (nominal) h 3,10 - i 0,00 - j 2,77 - NOTE 1 Reference plane. NOTE 2 The form and dimension of outer contact detent meet electrical and mechanical performance requirements. NOTE 3 The diameters are chosen upon the assumption that the PTFE dielectric has a d

34、ielectric constant of 2,02 to give an impedance of 50 . NOTE 4 Resilient contact may be closed or open entry, method of resilience is optional, provided that when a pin of 0,36 mm to 0,38 mm diameter is inserted, VSWR mating and endurance performances are obtained. BS EN 61169-19:2011 8 61169-19 IEC

35、:2011 3.1.2 Connector with pin-centre contact Note 1lpkmnqrsutzywxSee detail ANote 2Detail AvIEC 059/11Figure 2 Connector with pin-centre contact (for dimensions and notes, see Table 2) Table 2 Dimensions of connector with pin-centre contact Ref. mm Min. Max. k - 3,10 l 1,91 - m - 0,84 n 0,00 - p 2,

36、11 (nominal) q 1,37 - r - 2,67 s 0,00 - t 0,71 0,74 u 88 92 v 0,05 0,15 w - 2,75 x 1,91 - y - 0,25 z 0,36 0,38 NOTE 1 Reference plane. NOTE 2 The diameters are chosen upon the assumption that the PTFE dielectric has a dielectric constant of 2,02 to give an impedance of 50 . BS EN 61169-19:201161169-

37、19 IEC:2011 9 3.2 Gauges 3.2.1 Gauge pins for socket-centre contact ba0,20 mm max.50 2Blend radiusR0,4 mm max.IEC 055/11Figure 3 Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) Table 3 Dimensions of gauge pins for socket-centre contact Ref. Gauge A Maximum material for s

38、izing purposes Gauge B Minimum material for measurement of retention force mm mm Min. Max. Min. Max. a 0,381 0,384 0,353 0,356 b 1,70 1,80 1,70 1,80 Material: steel, polished, surface roughness: Ra=0,4 m maximum. Mass of gauge: 16 g 1 g 3.2.2 Test procedure The gauge A shall be inserted into the soc

39、ket-centre contact three times with a minimum depth of b . This is a sizing operation and should only be carried out when the socket-centre contact is removed from the connector. After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain the mass of the gauge in a

40、 vertical downward position. This test also shall be carried out on connector when the socket-centre contact is not removed. BS EN 61169-19:2011 10 61169-19 IEC:2011 3.2.3 Gauge for outer contact of socket-centre contact Reference planeahbd radiuse radius f radiusicg radius orchamfer permissiblekjIE

41、C 060/11Figure 4 Outer contact sizing and retention force gauges A and B (for dimensions and notes, see Table 4) Table 4 Dimensions of gauge for outer contact Ref Gauge A (maximum material for sizing purpose) Gauge B (minimum material for measurement of gauge retention force) mm mm Min. Max. Min. Ma

42、x. a 0,74 0,75 0,58 0,64 b 0,48 0,51 0,43 0,46 c 0,14 0,15 0,075 0,125 d - 0,08 - 0,08 e 0,08 0,18 0,08 0,18 f 0,2 0,4 0,2 0,4 g - 0,38 - 0,38 h 1,68 - 1,68 - i 2,672 2,675 2,667 2,670 k 3,05 3,10 3,05 3,10 j 3,50 - 3,50 - Material: steel, polished, surface roughness: Ra=0,4 m maximum. Mass of gauge

43、: 460 g 20 g 3.2.4 Test procedure The gauge A shall be inserted into the outer contact of the socket-centre contact three times. This is a sizing operation. After this, the gauge B shall be inserted into the outer contact of the socket-centre contact. The contact shall support the mass of the gauge

44、in a vertical downward position. BS EN 61169-19:201161169-19 IEC:2011 11 NOTE Additional test: Following the sizing operation, the force necessary to insert gauge A into the outer contact of the socket-centre contact is measured. When this test is required, the maximum permitted insertion force is t

45、hen specified and is smaller than 27 N. 3.3 Dimensions Standard test connectors Grade 0 3.3.1 Connector with socket-centre contact Note 1efNote 2Note 2Note 3hdi gcba0,12 mm A0,012 mm A0,010 mm Ak B0,07 mm BIEC 061/11Figure 5 Connector with socket-centre contact (for dimensions and notes, see Table 5

46、) Table 5 Dimensions of connector with socket-centre contact Ref. mm Min. Max. a 2,740 2,840 b 2,464 2,514 c 1,295 1,340 d - 1,780 e 0,000 0,127 f 2,110( nominal)g 0,000 0,127 h 0,840 0,942 i 3,100 3,150 k 2,770 - NOTE 1 Reference plane. NOTE 2 The diameters are chosen upon the assumption that the P

47、TFE dielectric has a dielectric constant of 2,02 to give an impedance of BS EN 61169-19:2011 12 61169-19 IEC:2011 50 0,5 .NOTE 3 Resilient contact may be closed or open entry, method of resilience optional, provided that when a pin of 0,36 mm to 0,38 mm diameter is inserted, VSWR mating and enduranc

48、e performances are obtained. 3.3.2 Connector with pin-centre contact Note 1mu0,12 mm AnlpAvwxyzB0,075 mm BaaabstqrNote 2Note 2Detail ASee detail AIEC 062/11Figure 6 Connector with pin-centre contact (for dimensions and notes, see Table 6) Table 6 Dimensions of connector with pin-centre contact Ref.

49、mm Min. Max. l 3,050 3,100 m 1,905 - n 0,740 0,840 p 0,000 0,127 q 0,710 0,740 r 89 to 91 s 0,120 0,150 t 0,080 radius u 2,110( nominal) v 1,370 1,420 w 2,620 2,670 x 0,000 0,050 y - 2,750 z 1,910 - BS EN 61169-19:201161169-19 IEC:2011 13 Ref. mm Min. Max. aa - 0,250 ab 0,360 0,380 NOTE 1 Reference plane. NOTE 2 The diameters are chosen

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf