BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf

上传人:wealthynice100 文档编号:577083 上传时间:2018-12-13 格式:PDF 页数:18 大小:587.18KB
下载 相关 举报
BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf_第1页
第1页 / 共18页
BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf_第2页
第2页 / 共18页
BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf_第3页
第3页 / 共18页
BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf_第4页
第4页 / 共18页
BS EN 61196-3-1999 Radio-frequency cables - Specifications - Sectional specification for coaxial cables for local area networks《射频电缆 规范 局域网用同轴电缆分规范》.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS EN 61196-3:1999 IEC 61196-3: 1998 Radio frequency cables Part 3: Sectional specification for coaxial cables for local area networks The European Standard EN61196-3:1998 has the status of a British Standard ICS 33.120.10BSEN61196-3:1999 This British Standard, havingbeen prepared u

2、nder thedirection of the Electrotechnical Sector Committee, was published underthe authority of the Standards Committee and comesinto effect on 15January1999 BSI 09-1999 ISBN 0 580 32005 7 National foreword This British Standard is the English language version of EN61196-3:1998. It is identical with

3、 IEC61196-3:1998. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, r.f. connectors, and accessories for communication and signalling, to Subcommittee EPL/46/1, Communication cables, which has the responsibility to: aid enquirers to un

4、derstand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented

5、on this subcommittee can be obtained on request to its secretary. From1 January1997, all IEC publications have the number60000 added to the old number. For instance, IEC27-1 has been renumbered as IEC60027-1. For a period of time during the change over from one numbering system to the other, publica

6、tions may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to international publications with their corresponding European publications. The British Standards which impleme

7、nt these international or European publications may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the nec

8、essary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, theEN

9、title page, pages2 to12 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSEN61196-3:1999 BSI 09-1999 i Co

10、ntents Page National foreword Inside front cover Foreword 2 Text of EN61196-3 5ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN61196-3 November1998 ICS 33.120.10 Descriptors: Radio frequency cables, local area networks English version Radio frequency cables Part3: Sectional specification

11、 for coaxialcablesforlocalarea networks (IEC61196-3:1998) Cbles pour frquences radiolectriques Partie3: Spcification intermdiaire pour cbles coaxiaux pour rseaux locaux (CEI61196-3:1998) Hochfrequenzkabel Teil3: Rahmenspezifikation fr Koaxialkabel fr lokale Netze (IEC61196-3:1998) This European Stan

12、dard was approved by CENELEC on1998-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerni

13、ng such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its

14、 own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, P

15、ortugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1998 CENELECAll rights of e

16、xploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN61196-3:1998 EEN61196-3:1998 BSI 09-1999 2 Foreword The text of document46A/323/FDIS, future edition1 of IEC61196-3, prepared by SC46A, Coaxial cables, of IEC TC46, Cables, wires, waveguides, R.F. connectors,

17、 and accessories for communication and signalling, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN61196-3 on1998-10-01. This EN61196-3 is to be used in conjunction with IEC61196-1:1995. The following dates were fixed: Annexes designated “normative” are part of the bo

18、dy of the standard. In this standard, Annex ZA is normative. Annex ZA has been added by CENELEC. Endorsement notice The text of the International Standard IEC61196-3:1998 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword 2 1 General 5 1.1 Scope and objec

19、t 5 1.2 Normative references 5 1.3 Definitions 5 1.4 Installation considerations 5 1.4.1 Pulling strength 5 1.4.2 Temperature rating 5 1.4.3 Bending radius 5 2 Materials and cable construction 5 2.1 General 5 2.2 Cable construction 5 2.3 Inner conductor 5 2.3.1 Conductor material 5 2.3.2 Conductor c

20、onstruction 6 2.4 Dielectric 6 2.5 Outer conductor or screen 6 2.6 Sheath 6 2.7 Colour of the sheath 6 2.8 Identification 6 2.8.1 Cable identification 6 2.8.2 Sheath marking 6 2.9 Delivery and storage 6 3 Characteristics and requirements 6 3.1 General 6 3.2 Engineering information 7 3.2.1 Connector

21、7 3.2.2 Mass 7 3.2.3 Bending radius 7 3.2.4 Capacitance 7 3.2.5 Voltage rating 7 3.3 Electrical integrity 7 3.3.1 Sheath spark test 7 3.3.2 Dielectric withstand voltage 7 3.3.3 Insulation resistance 7 3.4 Transmission characteristics 7 3.4.1 Characteristic impedance 7 3.4.2 Loop DCR 7 3.4.3 Outer co

22、nductor DCR 7 3.4.4 Attenuation 7 3.4.5 Attenuation after ageing 7 3.4.6 Velocity ratio 7 3.4.7 Surface transfer impedance 7 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop)1999-07-01 latest date by which the

23、 national standards conflicting with the EN haveto be withdrawn (dow)2001-07-01EN61196-3:1998 BSI 09-1999 3 Page 3.4.8 Screening attenuation 7 3.4.9 Return loss 7 3.5 Mechanical characteristics 7 3.5.1 Elongation after break of the inner conductor 7 3.5.2 Elongation after break of the insulation 7 3

24、.5.3 Tensile strength and elongation after break of the sheath 7 3.5.4 Tensile strength and elongation after break of the sheath after ageing 8 3.5.5 Bending at low temperature of the cable 8 3.5.6 Bending radius at room temperature 8 3.5.7 Dielectric adhesion 8 3.6 Environmental characteristics 8 3

25、.6.1 Cable test under fire conditions 8 3.6.2 Smoke opacity, toxicity, halogen gas emission 8 4 Quality assurance 8 5 Blank detail specification 8 5.1 Field of application 8 5.2 Identification of the detail specification 8 5.3 Pro forma blank detail specification 9 Annex ZA (normative) Normative ref

26、erencestointernational publications with their corresponding European publications 12 Figure 1 Maximum transfer frequency 114 blankEN61196-3:1998 BSI 09-1999 5 1 General 1.1 Scope and object This sectional specification specifies requirements for radio frequency coaxial cables for local area network

27、s. The object of this sectional specification is to prescribe recommended ratings and characteristics and to select from the generic specification the appropriate quality assessment procedures, test and measuring methods, and to give general performance requirements for coaxial cables for local area

28、 networks plus complementary test methods. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance levels. When the requirements of IEC61196-1 and of this sectional specification conflict with each other,

29、 this sectional specification shall prevail. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC61196. At the time of publication, the editions indicated were valid. All normative documents are

30、 subject to revision, and parties to agreements based on this part of IEC61196 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC60028

31、:1925, International Standard of resistance for copper. IEC60050(461):1994, International Electrotechnical Vocabulary (IEV) Chapter461:Electric cables. IEC60169, Radio-frequency connectors. IEC60304:1982, Standard colours for insulation for low-frequency cables and wires. IEC60332-1:1993, Tests on e

32、lectric cables under fire conditionsPart1: Test on a single vertical insulated wire or cable. IEC61196-1:1995, Radio-frequency cables Part1: Generic specification: General, definitions, requirements and test methods. 1.3 Definitions For the purpose of this specification, the terms and definitions gi

33、ven in IEC61196-1, IEC60050(461) and the following apply. 1.3.1 local area network a network provided within the premises 1.3.2 loop DCR summation of the d.c. resistances of the inner conductor and outer conductor (or screen) of a specified length of cable 1.3.3 loamed dielectric cable cable in whic

34、h all the space between the inner conductor and the outer conductor (or screen) is filled by a cellular dielectric. The cellular structure is uniformly distributed between the conductors and may be covered by a skin (solid dielectric) layer. IEC61196-1:1995, definition3.2.18 1.3.4 optimized braid on

35、e in which the braid angle, filling factor and wire diameter are chosen so as to result in a minimum measured surface transfer impedance magnitude on a specified frequency range 1.4 Installation considerations 1.4.1 Pulling strength The maximum allowable pulling force to be applied to the cable shal

36、l be limited to20N. 1.4.2 Temperature rating 1.4.3 Bending radius The minimum allowable bending radius shall be specified in the relevant detail specification. 2 Materials and cable construction 2.1 General Materials used shall comply with the requirements specified in IEC61196-1, except where such

37、requirements are modified by this specification. 2.2 Cable construction The cable construction shall be in accordance with the requirements given in the relevant detail specification. 2.3 Inner conductor 2.3.1 Conductor material The inner conductor shall consist of plain or tinned annealed copper un

38、iform in quality and free from defects. During installation: 0 C to+60 C Working and storage: 15 C to+60 CEN61196-3:1998 6 BSI 09-1999 The properties of the copper shall be in accordance with IEC60028 and if the inner conductor is tinned, it shall be tested in accordance with IEC61196-1, 5.5.2.1. 2.

39、3.2 Conductor construction The construction of the inner conductor shall be as specified in the relevant detail specification. Where the inner conductor consists of a single wire there shall be no joints in the wire made after the last drawing operation. Joints in individual strands of a stranded co

40、nductor shall be cold pressure welded, brazed or silver soldered using a non-acid flux such that the strand diameter shall not be increased. No joint in an individual strand shall be within0,3m of a joint in any other individual strand. 2.4 Dielectric The type of dielectric required for each cable s

41、hall be specified in the relevant detail specification. The diameter over dielectric, the ovality and the eccentricity shall be given in the relevant detail specification. 2.5 Outer conductor or screen The construction and material of the outer conductor and/or screen shall be as specified in the re

42、levant detail specification. The copper braid wires shall be uniform in quality and free from defects. The properties of the copper shall be in accordance with IEC60028, and if the copper wire is tinned, it shall be tested in accordance with IEC61196-1, 5.5.2.1. The outer conductor or screen may be:

43、 a) a braid of plain or tinned annealed copper wires. Joints in the braiding wires shall be soldered, twisted or woven in and there shall be no joint in the complete braid. The braid shall be evenly applied. The filling factor shall be specified in the relevant detail specification; b) a double brai

44、d of plain or tinned annealed copper wires. Joints in the braiding wires shall be soldered, twisted or woven in and there shall be no joint in the complete braid. The braid shall be evenly applied. The filling factor shall be specified in the relevant detail specification; c) a layer of metallized p

45、lastic film applied with a sufficient overlap, bonded or not bonded, covered with a tinned copper braid when the metal layer is aluminium and a plain copper braid when the metal layer is copper. Joints in the braiding wires shall be soldered, twisted or woven in and there shall be no joint in the co

46、mplete braid. The braid shall be evenly applied. The filling factor shall be specified in the relevant detail specification; d) any combination of the above. 2.6 Sheath The outer sheath of the cable shall be of plastic material as specified in the relevant detail specification. For safety reasons, f

47、lame retardant, low smoke and halogen-free materials may be required. Their characteristics and related test methods are under consideration. 2.7 Colour of the sheath The colour of the sheath shall be specified in the relevant detail specification. The colour should be in accordance with IEC60304. 2

48、.8 Identification 2.8.1 Cable identification Cable identification shall be made by markings on the sheath. 2.8.2 Sheath marking Sheath marking shall be in accordance with the relevant detail specification, with a repeat frequency of at least once per metre. The cable manufacturer and the relevant de

49、tail specification number shall be marked on the sheath. Sheath markings for safety rating, length, date of manufacture, etc. is optional. 2.9 Delivery and storage Delivery shall be made on drums or coils with suitable cable protection. The ends of the finished cable shall be adequately sealed to prevent the ingress of moisture. Sealing shall be carried out immediately after inspection and acceptance tests. 3 Characteristics and requirements 3.1 General This part lists the characteristics and requirements of cable made to this specification.

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1