BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf

上传人:刘芸 文档编号:577123 上传时间:2018-12-13 格式:PDF 页数:66 大小:1.13MB
下载 相关 举报
BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf_第1页
第1页 / 共66页
BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf_第2页
第2页 / 共66页
BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf_第3页
第3页 / 共66页
BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf_第4页
第4页 / 共66页
BS EN 61223-3-2-2008 Evaluation and routine testing in medical imaging departments -Part 3-2 Acceptance tests - Imaging performance of mammographic X-ray equipment《医学成像部门内的评估和例行测试 .pdf_第5页
第5页 / 共66页
亲,该文档总共66页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARDBS EN 61223-3-2:2008Evaluation and routine testing in medical imaging departments Part 3-2: Acceptance tests Imaging performance of mammographic X-ray equipmentICS 11.040.50g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g5

2、1g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61223-3-2:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 55611 1National forewordThis British Standar

3、d is the UK implementation of EN 61223-3-2:2008. It is identical to IEC 61223-3-2:2007. It supersedes BS EN 61223-3.2:1997 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee CH/62, Electromedical equipment in medical practice, to Subcommittee CH/62/2, Dia

4、gnostic imaging equipment.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard ca

5、nnot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 61223-3-2 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches

6、Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61223-3-2:2008 E ICS 11.040.50 Supersedes EN 61223-3-2:1996English version Evalua

7、tion and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment (IEC 61223-3-2:2007) Essais dvaluation et de routine dans les services dimagerie mdicale - Partie 3-2: Essais dacceptation - Performance dimagerie des appareils

8、de mammographie rayonnement X (CEI 61223-3-2:2007) Bewertung und routinemige Prfung in Abteilungen fr medizinische Bildgebung - Teil 3-2: Abnahmeprfungen - Leistungsmerkmale zur Bildgebung von Rntgen-Einrichtungen fr die Mammographie (IEC 61223-3-2:2007) This European Standard was approved by CENELE

9、C on 2008-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards

10、 may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

11、 to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, L

12、uxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 62B/651/FDIS, future edition 2 of IEC 61223-3-2, prepared by SC 62B, Diagnostic imaging equipment, of IEC TC 62, Electrical equip

13、ment in medical practice, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61223-3-2 on 2008-06-01. This European Standard supersedes EN 61223-3-2:1996. EN 61223-3-2:2008 has been expanded by including tests of equipment properties depending on X-RAY IMAGE RECEPTORS,

14、by putting emphasis on the aspect of image quality and dose and through harmonization, where possible, with other recognized standards. Annex L compares the specific content of EN 61223-3-2:1996 and EN 61223-3-2:2008. The following dates were fixed: latest date by which the EN has to be implemented

15、at national level by publication of an identical national standard or by endorsement (dop) 2009-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-06-01 In this standard, the following print types are used: requirements, compliance with which ca

16、n be tested, and definitions: roman type; explanations, advice, notes, general statements, exceptions and references: smaller type; TERMS DEFINED IN IEC/TR 60788, EN 60601-1 OR IN CLAUSE 3 OF THIS STANDARD: SMALL CAPITALS (see index of defined terms). NOTE 1 Where a defined term is used as a qualifi

17、er with another defined or undefined term, it is not printed in SMALL CAPITALS, unless the concept thus qualified is defined, or recognized as a derived term without a definition. NOTE 2 Where the concept addressed is not strongly confined to the definition given in one of the publications listed ab

18、ove, a corresponding term is printed in lower case letters. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61223-3-2:2007 was approved by CENELEC as a European Standard without any modification. _ BS EN 61223-3-2:2008 2 CONTENTS INTRODUCTION.5 1 S

19、cope.6 2 Normative references .7 3 Terms and definitions .8 4 General aspects of the ACCEPTANCE TEST11 4.1 Levels of compliance.11 4.2 General conditions in test procedures .11 4.3 Documents and data for the tests 12 4.4 Test conditions13 4.5 Scope of tests .13 4.6 Test EQUIPMENT .14 4.7 Evaluating

20、the test results .15 5 Test methods for mammographic X-RAY EQUIPMENT 16 5.1 Initial test and inventory 16 5.2 X-RAY TUBE VOLTAGE 16 5.3 HALF VALUE LAYER (HVL) 17 5.4 NOMINAL FOCAL SPOT VALUE 18 5.5 X-RAY FIELD limitation and beam alignment 18 5.6 Radiation output 19 5.7 AUTOMATIC EXPOSURE CONTROL (A

21、EC)19 5.8 Reproducibility of the AIR KERMA 25 5.9 ATTENUATION RATIO of material between the upper surface of the PATIENT SUPPORT and the IMAGE RECEPTION PLANE.25 5.10 Breast COMPRESSION DEVICE 26 5.11 Uniformity27 5.12 Dynamic range of mammographic X-RAY EQUIPMENT using digital X-ray image receptors

22、, including storage phosphor systems .29 5.13 Spatial resolution 30 5.14 LOW CONTRAST DETECTABILITY 33 5.15 Entrance surface AIR KERMA.34 5.16 Biopsy needle positioning accuracy of MAMMOGRAPHIC STEREOTACTIC DEVICES .35 6 Baseline values for CONSTANCY TESTS .36 7 Test report and statement of complian

23、ce 36 Annex A (informative) TEST DEVICES and arrangements for testing the automatic exposure control system with a digital X-RAY IMAGE RECEPTOR.38 Annex B (informative) TEST DEVICE for testing the dynamic range of systems with a digital X-RAY IMAGE RECEPTOR42 Annex C (informative) Test methods for s

24、creen-film X-ray image receptor .43 Annex D (informative) Test methods for storage phosphor system .45 BS EN 61223-3-2:2008 3 Annex E (informative) Example of a method for the determination of the AVERAGE GLANDULAR DOSE .48 Annex F (informative) Example of TEST DEVICES and arrangements for testing t

25、he system contrast transfer function for systems with a digital X-RAY IMAGE RECEPTOR.50 Annex G (informative) LOW CONTRAST DETECTABILITY test for mammographic X-RAY EQUIPMENT using an integrated digital X-RAY IMAGE RECEPTOR or storage phosphor plates .51 Annex H (informative) Example of a mammograph

26、ic stereotactic TEST DEVICE 53 Annex I (normative) Set-up for HALF-VALUE LAYER measurements .54 Annex J (informative) Definition of the ROIs for testing lag effects .55 Annex K (informative) ARTIFACTS and other non-uniformities56 Annex L (informative) Cross reference and history.58 Bibliography59 Te

27、rminology Index of defined terms .61 Figure A.1 Basic ATTENUATION Plates.38 Figure A.2 Alternative design for the top attenuating plate .39 Figure A.3 Alternative design for the two additional attenuating plates (two pieces required).40 Figure A.4 Measurement of CNR: 2-step methods41 Figure B.1 Test

28、 object for the dynamic range (to be used together with a 20 mm PMMA plate placed on top).42 Figure F.1 Example of 45 test pattern for the evaluation of the system contrast transfer function50 Figure H.1 Example of a mammographic stereotactic TEST DEVICE53 Figure I.1 Set-up for HALF-VALUE LAYER meas

29、urements.54 Figure J.1 Definition of the ROIs for testing lag effects.55 Table 1 Symbols, physical quantities, abbreviations and units used in this standard 10 Table 2 Examples of typical HALF-VALUE LAYERS (HVL) in millimetres of aluminium (mm Al) for mammographic X-RAY EQUIPMENT with different TARG

30、ET FILTER combinations operated at different X-RAY TUBE VOLTAGES .17 Table E.1 g for breasts simulated with PMMA 49 Table E.2 c for breasts simulated with PMMA 49 Table E.3 Typical HVL measurements for different tube voltage and TARGET FILTER combinations 49 Table E.4 s for clinically used spectra D

31、ance et al. 200049 Table L.1 Cross reference list for Editions 1 and 2 of this standard 58 BS EN 61223-3-2:2008 4 Annex ZA (normative) Normative references to international publications with theircorresponding European publications63INTRODUCTION This standard is part of a series of International Sta

32、ndards which give methods of acceptance testing and constancy testing for diagnostic X-RAY EQUIPMENT. This second edition of the particular standard for the ACCEPTANCE TEST of mammographic X-RAY EQUIPMENT describes test methods for EQUIPMENT using RADIOGRAPHIC FILMS, EQUIPMENT using storage phosphor

33、 plates, EQUIPMENT using integrated digital X-RAY IMAGE RECEPTORS, and MAMMOGRAPHIC STEREOTACTIC DEVICES. BS EN 61223-3-2:2008 5 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS Part 3-2: Acceptance tests Imaging performance of mammographic X-ray equipment 1 Scope This part of IEC 61223

34、 applies to the effectiveness of mammographic X-RAY EQUIPMENT, with respect to image quality and dose, in combination with aspects of EQUIPMENT safety. This standard applies to mammographic X-RAY EQUIPMENT and MAMMOGRAPHIC STEREOTACTIC DEVICES. The tests described in this standard require the qualit

35、y and performance of the X-RAY IMAGE RECEPTORS to be assured prior to the acceptance testing when they are not an integral part of the mammographic X-RAY EQUIPMENT. This includes RADIOGRAPHIC FILMS, INTENSIFYING SCREENS, RADIOGRAPHIC CASSETTES, storage phosphor plates and ASSOCIATED EQUIPMENT such a

36、s film processors or storage phosphor plate readers, IMAGE DISPLAY DEVICES and HARD COPY CAMERAS. For testing RADIOGRAPHIC CASSETTES and INTENSIFYING SCREENS, this standard makes reference to ISO 4090. Sensitivity and contrast for the screen-film image receptors are considered to be stated according

37、 to ISO 9236-3. NOTE Currently there exists no IEC standard for acceptance testing of HARD COPY CAMERAS or IMAGE DISPLAY DEVICES. By the measurements described in this standard, data for AVERAGE GLANDULAR DOSE calculation can be determined. When the results of the ACCEPTANCE TEST are in compliance w

38、ith the expected values, the baseline values for the subsequent CONSTANCY TESTS are established. This part of IEC 61223 defines a) the essential parameters which describe the performance of the above-mentioned mammographic X-RAY EQUIPMENT with regard to image quality and dose; and b) the methods of

39、testing whether measured quantities related to those parameters comply with specified tolerances. These methods mainly rely on non-invasive measurements that use appropriate test EQUIPMENT and are performed during or after the installation. Signed statements covering steps in the installation proced

40、ure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance. This concept is described in 4.1. BS EN 61223-3-2:2008 6 This standard does not in itself specify limiting values or tolerances for the

41、parameters under investigation. A difficulty may arise with regard to the responsibility for acceptance testing when the film/screen combination, film processing chemistry or computed radiography system is changed. This arises from a combination of causes. Firstly, the image receptor MANUFACTURER an

42、d the X-RAY EQUIPMENT MANUFACTURER may be different. Secondly a change in image receptor or film processing chemistry may alter the system performance. When system integration such as the above occurs, it is important that acceptance testing is performed. When a change occurs which could alter syste

43、m performance, it is essential that the system integrator (i.e. whoever is responsible for this change) discusses the implication of their change with the X-RAY EQUIPMENT MANUFACTURER so that the latter can adjust the imaging system if necessary. ACCEPTANCE TESTING of mammographic X-RAY EQUIPMENT re

44、quires average skill in medical physics. However, the decision concerning who performs the test is determined by local rules (e.g. contract, regulation, law). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only

45、the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60336:2005, Medical electrical equipment X-ray tube assemblies for medical diagnosis Characteristics of focal spots IEC 60601 (all parts), Medical electrical equip

46、ment IEC 60601-1, Medical electrical equipment Part 1: General requirements for basic safety and essential performance IEC 60601-2-45, Medical electrical equipment Part 2-45: Particular requirements for the safety of mammographic X-ray equipment and mammographic stereotactic devices IEC 61223-2-1, E

47、valuation and routine testing in medical imaging departments Part 2-1: Constancy tests Film processors IEC 61674, Medical electrical equipment Dosimeters with ionization chambers and/or semi-conductor detectors as used in X-ray diagnostic imaging IEC 61676:2002, Medical electrical equipment Dosimetr

48、ic instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology ISO 4090, Photography Medical radiographic cassettes/screens/films and hard-copy imaging films Dimensions and specifications ISO 9236-3, Photography Sensitometry of screen/film systems for medical radiogra

49、phy Part 3: Determination of sensitometric curve shape, speed and average gradient for mammography BS EN 61223-3-2:2008 7 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. NOTE Symbols, physical quantities, abbreviations and units used in this standard are given at the end of this clause in Table 1. 3.1 ACCEPTANCE TEST test carried out after new EQUIPMENT has been installed, or major modifications have been mad

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1