1、BRITISH STANDARD BS EN 61269-1-1:1997 IEC 1269-1-1: 1994 Fibre optic terminus sets Part 1-1: Blank detail specification The European Standard EN61269-1-1:1997 has the status of a British Standard ICS 33.180.10BS EN61269-1-1:1997 This British Standard, having been prepared under the direction of the
2、Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15July1997 BSI 09-1999 ISBN 0 580 27727 5 National foreword This British Standard is the English language version of EN61269-1-1:1997. It is identical with IEC1269-1-1:1994. The UK partic
3、ipation in its preparation was entrusted to Technical Committee EPL/86, Fibre optics, to Subcommittee EPL/86/2, Interconnecting devices and passive components, which has the repsonsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enqui
4、ries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The Brit
5、ish Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British S
6、tandard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cov
7、er, an inside front cover, pages i and ii, the EN title page, pages 2 to 10 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd
8、. No. Date CommentsBS EN61269-1-1:1997 BSI 09-1999 i Contents Page National foreword Inside front cover Foreword 2 Text of EN 61269-1-1 3ii blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61269-1-1 February 1997 ICS 33.180.20 English version Fibre optic terminus sets Part 1-1: Blank detail
9、 specification (IEC 1269-1-1:1994) Jeux dembouts pour fibres optiques Partie 1-1: Spcification particulire cadre (CEI 1269-1-1:1994) Kontakteinstze fr Lichtwellenleiter Teil 1-1: Vordruck fr Bauartspezifikation (IEC 1269-1-1:1994) This European Standard was approved by CENELEC on1996-10.01. CENELEC
10、members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on appli
11、cation to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretari
12、at has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC Eur
13、opean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for C
14、ENELEC members. Ref. No. EN 61269-1-1:1997 EEN61269-1-1:1997 BSI 09-1999 2 Foreword The text of the International Standard IEC1269-1-1:1994, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC86, Fibre optics, was submitted to the formal vote and was approved by
15、 CENELEC as EN61269-1-1 on1996-10-01 without any modification. The following dates were fixed: Endorsement notice The text of the International Standard IEC1269-1-1:1994 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword 2 1 Scope 3 2 Qualification approv
16、al 3 3 Quality conformance inspection 3 4 Detail specification worksheet 3 Table 1 Fixed-sample test schedule for qualification approval 7 Table 2 Lot-by-lot quality conformance inspection schedule Group A and B 8 Table 3 Periodic quality conformance inspection schedule Group C And D 9 Table 4 Detai
17、ls, measurements and performance requirements 10 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1997-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 1997
18、-09-01EN61269-1-1:1997 BSI 09-1999 3 1 Scope This blank detail specification is not, by itself, a specification. It is part of IEC1269-1 (QC780000): Generic specification. It includes a blank worksheet with instructions for preparing detail specifications. 2 Qualification approval 2.1 Procedure The
19、detail specification shall state the qualification approval procedure to be used (see3.3 of IEC1269-1). 2.2 Test schedule and performance requirements The test schedules for qualification by the fixed-sample procedure shall be defined inTable 1 of the detail specification worksheet (seeclause4). 3 Q
20、uality conformance inspection 3.1 Lot-by-lot inspection The test schedules for lot-by-lot inspection (groups A and B) shall be defined inTable 2 of the detail specification worksheet (seeclause4). 3.2 Periodic inspection The test schedules for periodic inspection (groups C and D) shall be defined in
21、Table 3 of the detail specification worksheet (seeclause4). 4 Detail specification worksheet The following worksheet is provided to aid in the preparation of detail specifications. Spaces are provided for entering information. When the spaces are completed, the detail specification can be drafted in
22、 its final form. The spaces are identified by numbers between square brackets. Instructions for completing these numbered spaces are given below. When drafting the final detail specification, the square-bracketed instruction numbers shall be eliminated. 1 The national IEC number assigned to the deta
23、il specification is added by the National Committee. 2 The date of the detail specification is added by the National Committee. 3 Enter the name and address of the National Committee. 4 Enter the applicable classification categories (see2.2 of IEC1269-1). 5 If the terminus set is not classified by c
24、limatic category, add the words “not applicable”. 6 A standard environmental category may be selected fromAnnex A of IEC1269-1. If a sequence other than a standard from Annex A is used, add “none”. 7 Add the assessment level classification (see2.2.7 of IEC 1269-1). 8 Add the qualification procedure
25、required for the detail specification (fixed-sample procedure or lot-by-lot procedure see3.3 of IEC1269-1). 9 Specify the component(s) control dimensions in the format shown. Include: component(s) control dimensions; control dimensions for all variants. Add figures showing the dimensions for standar
26、d reference components and gauges, if required. Display the drawings in the format shown. 10 Tabulate the identification number for each variant of each component (see2.6.1 of IEC1269-1). Assign a column in the table for each variant feature. For example, alternative plating, etc. 11 Enter supplemen
27、tary information with respect to marking, requirements for certified records of released lots and other appropriate information (see2.6.2, 2.6.3 and 3.5 of IEC1269-1). 12 Enter the required measurements and tests for qualification by fixed-sample size inTable 1. If qualification by lot-by-lot and pe
28、riodic procedure is specified, eliminate the table and renumber subsequent tables in the detail specification accordingly.EN61269-1-1:1997 4 BSI 09-1999 Enter the procedure reference in note form to the table. Specify the sample size for each group in column“n”. 13 Enter the required measurements an
29、d tests for groups A and B inTable 2. Enter the procedure reference in note form to the table. Add the assessment level designation along with the inspection level and AQL in the appropriate place in the table (see2.2.5 of IEC1269-1). 14 Enter the required measurements and tests for groups C and D i
30、nTable 3. Enter the procedure reference in note form to the table. Add the assessment level designation along with the sample size, “n”, and the inspection period, “p”, in the appropriate place in the table (see2.2.7 of IEC1269-1). 15 When completed, Table 4 will contain the details, measurements an
31、d the performance requirements for all tests and measurements which appear inTable 1, Table 2 and Table 3. The format for measurements appears on lines 16, 17, and 18. Enter the measurement procedure title and reference location on line 16 and the measurement details on lines 17. The requirements fo
32、r independent measurements (measurements which are not part of an environmental test) shall either be specified as a note to the table where it was added (Table 1, Table 2 or Table 3) or included inTable 4 under the appropriate measurement on lines 18. The requirements for dependent measurements (me
33、asurements which are part of an environmental test) shall be specified under the environmental test inTable 4. The format for environmental tests appears on lines 19, 20, 21, 22, and 23. Enter the test procedure title and reference location on line 19. Enter the test details on lines 20. Enter the i
34、nitial measurements to be made along with the performance requirements on line 21. Enter the measurements to be made during the test along with the performance requirements on line 22. Enter the final measurements to be made along with the performance requirements on line 23.EN61269-1-1:1997 BSI 09-
35、1999 5EN61269-1-1:1997 6 BSI 09-1999EN61269-1-1:1997 BSI 09-1999 7 10 VARIANT IDENTIFICATION NUMBERS Number: QC 780001/YYYY-ZZZZ ZZZZ Component name Variant feature Variant feature Variant feature 11 SUPPLEMENTARY INFORMATION Component marking: When specified, add component marking requirements here
36、 (see 2.6.2 of IEC 1269-1). Component package marking: When specified, add component package marking requirement here (see 2.6.3 of IEC 1269-1). Certified records of released lots: Indicate whether a certified record of released lots is required (see 3.5 of IEC 1269-1).EN61269-1-1:1997 8 BSI 09-1999
37、EN61269-1-1:1997 BSI 09-1999 9EN61269-1-1:1997 10 BSI 09-1999blankBS EN 61269-1-1:1997 IEC 1269-1-1: 1994 BSI 389 Chiswick High Road London W4 4AL BSIBritishStandardsInstitution BSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in E
38、urope and at the international level. It is incorporated by Royal Charter. Revisions BritishStandards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our prod
39、ucts and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this BritishStandard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel:02089969000. Fax:02089967400. BSI offers members
40、an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel:02089969001. Fax:02089967001. In respo
41、nse to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as BritishStandards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through
42、its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel:02089967111. Fax:02089967048. Subscribing members of BSI are kept up to date with standards
43、 developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel:02089967002. Fax:02089967001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publi
44、cations of the internationalstandardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permi
45、ssion from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel:02089967070.