BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf

上传人:inwarn120 文档编号:577321 上传时间:2018-12-13 格式:PDF 页数:14 大小:1,000.48KB
下载 相关 举报
BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf_第1页
第1页 / 共14页
BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf_第2页
第2页 / 共14页
BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf_第3页
第3页 / 共14页
BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf_第4页
第4页 / 共14页
BS EN 61300-2-52-2013 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Tests Bending test for cords《光纤互连器件和无源元件 基本试验和测量程序 试验 线芯抗弯试验》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards PublicationFibre optic interconnecting devices and passive components Basic test and measurement proceduresPart 2-52: Tests Bending test for cordsBS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo rep

2、roduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 61300-2-52:2013. It isidentical to IEC 61300-2-52:2013.BSI, as a member of CEN, is obliged to publish EN 61300-2-52 as a BritishStandard. However, attention is drawn t

3、o the fact that during the development of this European Standard, the UK committee voted againstits approval as a European Standard. The committee noted a possible inconsistency between clause 3, whichstates that optical measurements should be made before and after thetest, and clause 5.4, c) which

4、states that optical measurements are alsomade during the test. The committee is also of the opinion that the mention of fibre, cable and resilient members being fixed together inclause 4.3 may not be appropriate for all fibre optic connectors.The UK participation in its preparation was entrusted by

5、TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions

6、ofa contract. Users are responsible for its correct application. The British Standards Institution 2014Published by BSI Standards Limited 2014ISBN 978 0 580 70942 5ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under t

7、he authority of theStandards Policy and Strategy Committee on 31 March 2014.Amendments/corrigenda issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleN

8、o reproduction or networking permitted without license from IHS-,-,-EUROPEAN STANDARD EN 61300-2-52 NORME EUROPENNE EUROPISCHE NORM May 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normun

9、g Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-52:2013 E ICS 33.180.20 English version Fibre optic interconnecting devices and passive components - Basic test

10、and measurement procedures - Part 2-52: Tests - Bending test for cords (IEC 61300-2-52:2013) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 2-52: Essais - Essai de courbure pour les cordons (CEI 61300-2-52:2013) Lichtwellenl

11、eiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-52: Prfungen - Biegeprfung fr konfektionierte Kabel (IEC 61300-2-52:2013) This European Standard was approved by CENELEC on 2013-03-28. CENELEC members are bound to comply with the CEN/CENELEC Internal Re

12、gulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELE

13、C member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official v

14、ersions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,

15、 the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking perm

16、itted without license from IHS-,-,-EN 61300-2-52:2013 - 2 - Foreword The text of document 86B/3547/FDIS, future edition 1 of IEC 61300-2-52, prepared by SC 86B, “Fibre optic interconnecting devices and passive components“, of IEC TC 86, “Fibre optics“ was submitted to the IEC-CENELEC parallel vote a

17、nd approved by CENELEC as EN 61300-2-52:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2013-12-28 latest date by which the national standards conflicting with the

18、document have to be withdrawn (dow) 2016-03-28 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the Inte

19、rnational Standard IEC 61300-2-52:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60794-1-2 NOTE Harmonized as EN 60794-1-2. IEC 61300-3-28 NOTE Harmonized a

20、s EN 61300-3-28. BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3 - EN 61300-2-52:2013 Annex ZA (normative) Normative references to internation

21、al publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the

22、referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61300-1 - Fibre optic interconnecting devices and passive components - Basic

23、 test and measurement procedures - Part 1: General and guidance EN 61300-1 - IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 - IEC 61300-3-3 - Fibre optic in

24、terconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss EN 61300-3-3 - IEC 61300-3-4 - Fibre optic interconnecting devices and passive components - Basic test and meas

25、urement procedures - Part 3-4: Examinations and measurements - Attenuation EN 61300-3-4 - BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 2 6130

26、0-2-52 IEC:2013 CONTENTS 1 Scope . 5 2 Normative references 5 3 General description . 5 4 Apparatus . 5 4.1 General . 5 4.2 Cord 5 4.3 Specimen 6 4.4 Optical measurements . 6 5 Procedure . 6 5.1 General . 6 5.2 Preconditioning 6 5.3 Initial examinations and measurements 6 5.4 Procedure 6 5.5 Final e

27、xaminations and measurements 7 6 Severity 7 7 Details to be specified . 8 Bibliography 9 Figure 1 Specimen fixed onto mandrel 7 Figure 2 Cable wrapped around mandrel 7 Figure 3 Required number of mandrel rotations applied 7 Table 1 Severity . 8 BS EN 61300-2-52:2013Copyright British Standards Instit

28、ution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-61300-2-52 IEC:2013 5 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-52: Tests Bending test for

29、 cords 1 Scope This part of the IEC 61300 series describes a procedure to determine the suitability of a cord to withstand bending around a mandrel of the sort to be applied during normal use. This test is only applied to single fibre cables and multiple fibre circular cables. It is not applicable t

30、o ribbon cables. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (in

31、cluding any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examin

32、ations and measurements Visual examination IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss IEC 61300-3-4, Fibre optic interconnecting de

33、vices and passive components Basic test and measurement procedures Part 3-4: Examinations and measurements Attenuation 3 General description The purpose of this test is to determine the capability of the cord when repeatedly bent. Optical measurements are made before and after the test to screen for

34、 evidence of damage to the fibre/cable. 4 Apparatus 4.1 General A single mandrel apparatus shall enable the sample to be wrapped tangentially in a close helix around a single test mandrel. 4.2 Cord A cord is a fibre optic cable terminated with any passive fibre optic connector on both ends, regardle

35、ss of its expected use. Examples include equipment cords, work area cords or patchcords. BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,- 6 61300

36、-2-52 IEC:2013 4.3 Specimen The specimen shall be a cord. The connectors shall be terminated according to the manufacturers instructions so that the fibre, cable and resilient members are fixed together. 4.4 Optical measurements Unless otherwise specified, measuring equipment specified in IEC 61300-

37、3-4 shall be connected to the specimen for monitoring optical performance during the test. 5 Procedure 5.1 General Sufficient tension shall be applied to ensure that the sample contours the mandrel. The sample shall then be unwrapped. A cycle consists of one wrapping and one unwrapping. The diameter

38、 of the test mandrel, the number of turns of the mandrel and the number of cycles shall be shown in the relevant specification. 5.2 Preconditioning Precondition the specimen and all equipment for 2 h under standard test conditions as defined in IEC 61300-1, unless otherwise specified in the relevant

39、 specification. 5.3 Initial examinations and measurements Complete the initial examinations and measurements. 5.4 Procedure a) Connect the specimen to the optical measurement equipment according to IEC 61300-3-3. b) The specimen shall be initially positioned as shown in Figure 1. The two straight se

40、ctions shall be perpendicular to the mandrel and spacing between the two straight sections shall be such that the diameter of the loop is greater than the cables minimum bend diameter. c) Start the optical power measurements. d) The specimen shall be wrapped around the mandrel at a uniform tension s

41、uch that there are no gaps between the cable and the mandrel during the bending cycles (see Figure 2). The required number of turns around the mandrel shall be applied. Each revolution of cable on the mandrel shall be close to the adjacent revolutions or cable wraps (see Figure 3). e) The specimen s

42、hall be kept in this position for at least 1 min. f) The specimen shall be unwrapped and kept in this position for at least 1 min. g) The required number of cycles shall be applied by repeating steps d) to f) in a timely manner at a rate no greater than 1 wrap per minute. h) Stop optical power measu

43、rements. BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-61300-2-52 IEC:2013 7 Specimen Mandrel IEC 482/13 Figure 1 Specimen fixed onto mandrel I

44、EC 483/13 Figure 2 Cable wrapped around mandrel IEC 484/13 Figure 3 Required number of mandrel rotations applied 5.5 Final examinations and measurements Unwrap the cable from the mandrel and make the final measurements, as defined by the relevant specification, to ensure that there is no permanent d

45、amage to the specimen. The results of the final measurement shall be within the limit established in the relevant specification. Visually check (IEC 61300-3-1) that the cable and fibre optic device are not damaged. 6 Severity Severity consists of the combination of the number of turns per helix, num

46、ber of cycles, mandrel diameter and cord length. The severity shall be specified in the relevant specification or taken from Table 1 below: BS EN 61300-2-52:2013Copyright British Standards Institution Provided by IHS under license with BSI - Uncontrolled Copy Not for ResaleNo reproduction or network

47、ing permitted without license from IHS-,-,- 8 61300-2-52 IEC:2013 Table 1 Severity Mandrel diameter 60 mm for cable diameter 4 mm 15 cable diameter for cable diameter 4 mm Number of mandrel rotations 6 Number of cycles 3 Length of specimen sufficient to carry out the test Distance between connectors

48、 and mandrel when completely wrapped 200 mm 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification: a) cable and connector type; b) wavelength of the attenuation measurement; c) initial examinations and measurements and performance requirements; d) examinations and measurements during test and performance requirements; e) final examinations and measurements and performance requirements; f) deviations from test procedure; g) additional pass/fail criteria; h)

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1