BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf

上传人:sumcourage256 文档编号:577364 上传时间:2018-12-13 格式:PDF 页数:22 大小:1.28MB
下载 相关 举报
BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf_第1页
第1页 / 共22页
BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf_第2页
第2页 / 共22页
BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf_第3页
第3页 / 共22页
BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf_第4页
第4页 / 共22页
BS EN 61300-3-51-2014 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Examinations and measurements Pin gauge withdrawal force for .pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards PublicationFibre optic interconnecting devices and passive components Basic test and measurement proceduresPart 3-51: Examinations and measurements Pin gauge withdrawal force for rectangular ferrule multi-fibre connectorsBS EN 61300-3-51:2014National forewordThis British Standard is th

2、e UK implementation of EN 61300-3-51:2014. It isidentical to IEC 61300-3-51:2014.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizations represented o

3、n this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 79343 1I

4、CS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 December 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN

5、61300-3-51:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 61300-3-51 November 2014 ICS 33.180.20 English Version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-51: Examinations and measurements - Pin gaugewithdrawal force for rectan

6、gular ferrule multi-fibre connectors (IEC 61300-3-51:2014) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 3-51: Examens et mesures - Forcedextraction dune broche calibre pour des connecteursmultifibres frule rectangulaire (C

7、EI 61300-3-51:2014) Lichtwellenleiter - Verbindungselemente und passiveBauteile - Grundlegende Prf- und Messverfahren - Teil 3-51: Untersuchungen und Messungen - Prfstift-Ausziehkraft von rechteckigen Ferrulen von Mehrfachfasersteckverbindern (IEC 61300-3-51:2014) This European Standard was approved

8、 by CENELEC on 2014-11-14. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national

9、standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own la

10、nguage and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Fra

11、nce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de No

12、rmalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61300-3-51:2014 E EN 61300-3-51:2014

13、- 2 - Foreword The text of document 86B/3817/FDIS, future edition 1 of IEC 61300-3-51, prepared by SC 86B “Fibre optic interconnecting devices and passive components” of IEC/TC 86 “Fibre optics“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61300-3-51:2014. The followi

14、ng dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-08-14 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-11-14 Attention

15、is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61300-3-51:2014 was approved by CE

16、NELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 61300-3-49 NOTE Harmonized as EN 61300-3-49. BS EN 61300-3-51:2014- 3 - EN 61300-3-51:2014 Annex ZA (normative) Normative references t

17、o international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest ed

18、ition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex

19、 is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 - IEC 61754-5 - Fibre optic connector in

20、terfaces - Part 5: Type MT connector family EN 61754-5 - IEC 61754-7-1 - Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-1: Type MPO connector family - One fibre row EN 61754-7-1 - IEC 61754-7-2 - Fibre optic interconnecting devices and passive

21、components - Fibre optic connector interfaces - Part 7-2: Type MPO connector family - Two fibre rows EN 61754-7-2 - IEC 61754-10 - Fibre optic connector interfaces - Part 10: Type Mini-MPO connector family EN 61754-10 - IEC 61754-18 - Fibre optic connector interfaces - Part 18: Type MT-RJ connector

22、family EN 61754-18 - BS EN 61300-3-51:2014 2 IEC 61300-3-51:2014 IEC 2014 CONTENTS 1 Scope 6 2 Normative references 6 3 General description . 7 3.1 General . 7 3.2 Test conditions . 7 4 Apparatus 7 4.1 Fixture 7 4.2 Pin gauge chuck . 7 4.3 Plug gauge chuck . 7 4.4 Pin gauge . 7 4.5 Plug gauge . 8 4.

23、6 Weight 9 4.7 Tensile testing machine 9 5 Procedure 9 5.1 Method A: Method using the weight (Figure 3) 9 5.2 Method B: Method using the tensile testing machine (Figure 4) . 10 6 Details to be specified . 12 Annex A (informative) Experimental verification of the interchangeability between the pin ga

24、uge insertion force and the pin gauge withdrawal force . 13 A.1 General . 13 A.2 Measurement system 13 A.3 Measurement sample 13 A.4 Measurement procedure . 14 A.5 Measurement results . 14 A.6 Conclusion 15 Annex B (informative) Experimental verification of compatibility of Method A (method using th

25、e weight) and Method B (method using the tensile testing machine) . 16 Bibliography 17 Figure 1 Pin gauge. 8 Figure 2 Plug gauge for guide pin holes . 8 Figure 3 Method A for examination of pin gauge/plug gauge withdrawal force (method using the weight) . 10 Figure 4 Method B for examination of pin

26、gauge/plug gauge withdrawal force (method using the tensile testing machine) . 11 Figure A.1 Measurement system 13 Figure A.2 Insertion/withdrawal force measurement results 14 Figure B.1 Relation between the withdrawal force values measured by Method A and Method B 16 BS EN 61300-3-51:2014IEC 61300-

27、3-51:2014 IEC 2014 3 Table 1 Test conditions 7 Table 2 Dimensions of the pin gauge . 8 Table 3 Dimensions for plug gauge for guide pin holes 9 Table A.1 Guide hole pitch of measurement samples . 14 BS EN 61300-3-51:2014 6 IEC 61300-3-51:2014 IEC 2014 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE C

28、OMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 3-51: Examinations and measurements Pin gauge withdrawal force for rectangular ferrule multi-fibre connectors 1 Scope This part of IEC 61300 is intended to describe the procedure required to measure the pin gauge withdrawal force for rectangular f

29、errule multi-fibre connectors. This measurement can be used as an alternative to the measurement of the pin gauge insertion force, both of which evaluate the fit of the pin gauge(s) into the guide pin hole(s) of the female-type connector. The experimental verification of interchangeability between t

30、hem is shown in Annex A. For the male-type connector, IEC 61300-3-49 is applied to evaluate how securely the guide pins are retained in the guide holes. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its appl

31、ication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinati

32、ons and measurements Visual examination IEC 61754-5, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 5: Type MT connector family IEC 61754-7-1, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7-1: Type

33、MPO connector family One fibre row1IEC 61754-7-2, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7-2: Type MPO connector family Two fibre rows1 IEC 61754-10, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces

34、Part 10: Type Mini-MPO connector family IEC 61754-18, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 18: Type MT-RJ connector family _ 1To be published. BS EN 61300-3-51:2014IEC 61300-3-51:2014 IEC 2014 7 3 General description 3.1 General This measur

35、ement method is applied for optical connectors specified in IEC 61754-5, IEC 61754-7-1, IEC 61754-7-2, IEC 61754-10 and IEC 61754-18. Two methods using weights or a tensile testing machine are described in this standard. The optical connector is held using a fixture. For the measurement for a single

36、 guide pin hole, the pin gauge is placed in a pin gauge chuck and the weight or the tensile testing machine is connected to the pin gauge chuck. For the measurement for two guide pin holes, the plug gauge is placed in a plug gauge chuck and the weight or the tensile testing machine is connected to t

37、he plug gauge chuck. By using the plug gauge, it is possible to check not only the size of each guide pin hole but also the relative position and the relative angle between two guide pin holes. 3.2 Test conditions For a precise measurement such as design verification, the test conditions shall be co

38、ntrolled accurately as required in Table 1. Table 1 Test conditions Temperature C Relative humidity % RH 22,0 24,0 50,0 10,0 4 Apparatus 4.1 Fixture The measurement shall not be affected by the connector fixture. The position and direction of the connector during the test shall not change as the tes

39、t is repeated. The connector shall be placed in the fixture so that the front face of the connector housing is retained by the fixture as shown in Figure 3 and Figure 4. 4.2 Pin gauge chuck The pin gauge chuck shall have a pin gauge retention force much greater than the required connector pin gauge

40、withdrawal force, typically more than 200 N when using a tensile testing machine. The connection of the pin gauge to the weight or the tensile testing machine chuck shall not affect the measurement. 4.3 Plug gauge chuck The plug gauge chuck shall have a plug gauge retention force much greater than t

41、he required connector plug gauge withdrawal force, typically more than 200 N, when using a tensile testing machine. The connection of the plug gauge to the weight or the tensile testing machine chuck shall not affect the measurement. 4.4 Pin gauge Figure 1 and Table 2 show the pin gauge and dimensio

42、ns of the pin gauge. The pin gauge shall have the required dimensions as specified in IEC 61754-5. BS EN 61300-3-51:2014 8 IEC 61300-3-51:2014 IEC 2014 Figure 1 Pin gauge Table 2 Dimensions of the pin gauge Reference Dimensions mm Remarks Minimum Maximum A B aBA BB BC b0,698 5 10,8 0,2 0,2 6,0 0,699

43、 0 11,2 0,4 0,5 aTypical dimensions. bSurface roughness Rz= 0,1 m for the length of dimension BC. 4.5 Plug gauge Figure 2 and Table 3 show the plug gauge and its dimensions. The plug gauge shall have the required dimensions as specified in IEC 61754-5. Figure 2 Plug gauge for guide pin holes IEC 0,0

44、00 5ABABB BC B IEC 0,000 5 ABABB BC U DCW 0,001 W BS EN 61300-3-51:2014IEC 61300-3-51:2014 IEC 2014 9 Table 3 Dimensions for plug gauge for guide pin holes Reference Dimensions mm Remarks Minimum Maximum A C D aU aBA BB BC b0,698 5 4,599 5 6,3 2,4 0,2 0,2 6,0 0,699 0 4,600 5 6,5 2,5 0,4 0,5 6,5 For

45、two pins aTypical dimensions. bSurface roughness Rz= 0,1 m for the length of dimension BC. 4.6 Weight The weight to be used depends on the test to be carried out. The weight measurement is used for pass/fail tests including final inspection. 4.7 Tensile testing machine The tensile testing machine sh

46、all be able to record (and/or hold) the maximum value during the measurement. The tensile testing machine measurement is used for design verification testing. 5 Procedure 5.1 Method A: Method using the weight (Figure 3) The following steps shall be taken: a) Prepare the device under test (DUT) accor

47、ding to the manufacturers instructions and check the appearance in accordance with IEC 61300-3-1. b) Place the DUT in the fixture. c) Place the pin gauge or the plug gauge in the chuck. d) Insert the pin gauge or the plug gauge into the guide pin hole(s) of the connector by more than 5,5 mm. e) Fix

48、the weight to the chuck. Adjust the total weight of the jig and the weight to the specified value. f) Apply the weight slowly. Be sure that the force is applied along the axis of the guide pin hole(s). g) Wait for the specified duration. Record if the pin gauge or the plug gauge is withdrawn by the

49、specified force. Unless otherwise specified, the maximum duration shall be 15 s. BS EN 61300-3-51:2014 10 IEC 61300-3-51:2014 IEC 2014 Figure 3a Measurement for single hole Figure 3b Measurement for two holes Figure 3 Method A for examination of pin gauge/plug gauge withdrawal force (method using the weight) 5.2 Method B: Method using the tensile testing machine (Figure 4) The following steps shall be ta

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1