1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58(
2、EMS-API) Part 402: Common servicesICS 33.200Energy management system application program interface BRITISH STANDARDBS EN 61970-402:2008BS EN 61970-402:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIThis British Standard was published under the
3、authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 56436 9Amendments/corrigenda issued since publicationDate Commentscontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obli
4、gations.National forewordThis British Standard is the UK implementation of EN 61970-402:2008. It is identical to IEC 61970-402:2008.The UK participation in its preparation was entrusted to Technical Committee PEL/57, Power systems management and associated information exchange.A list of organization
5、s represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a EUROPEAN STANDARD EN 61970-402 NORME EUROPENNE EUROPISCHE NORM August 2008 CENELEC European Committee for Electrotechnical Standardization Comit
6、Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61970-402:2008 E ICS 33.200
7、 English version Energy management system application program interface (EMS-API) - Part 402: Common services (IEC 61970-402:2008) Interface de programmation dapplication pour systmes de gestion dnergie (EMS-API) - Partie 402: Services communs (CEI 61970-402:2008) Schnittstelle fr Anwendungsprogramm
8、e fr Netzfhrungssysteme (EMS-API) - Teil 402: Allgemeine Dienste (IEC 61970-402:2008) This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the statu
9、s of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German).
10、A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyp
11、rus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO
12、/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIForeword The text of document 57/928/FDIS, future edition 1 of IEC 61970-402, prepared by IEC TC 57, Power systems management and associated information exchange, was submitted to the IEC-CENELEC parallel vote and was approved by
13、 CENELEC as EN 61970-402 on 2008-07-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-04-01 latest date by which the national standards conflicting with the EN have to
14、be withdrawn (dow) 2011-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61970-402:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 61970-402:2008 2 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06
15、/01/2009 01:14, Uncontrolled Copy, (c) BSICONTENTS INTRODUCTION.5 1 Scope.6 2 Normative references7 3 Terms and definitions .7 4 Background 7 5 Common services identifiers (normative).8 5.1 DAF resource identifiers interface 8 5.2 Extended resource ID service 9 5.2.1 General .9 5.2.2 get_uris().10 5
16、.2.3 set_uris() .10 5.2.4 create_resource_ids() 11 6 Common services descriptions (normative) .11 7 IECTC 57Views (normative) 13 7.1 General .13 7.2 IECTC 57View motivations (informative) 13 7.2.1 General .13 7.2.2 Problem example (informative).14 7.2.3 IECTC 57View description (normative) .15 7.2.4
17、 IECTC 57View examples (informative) .15 7.2.5 Node properties (normative).17 7.3 The IECTC 57Physical view (normative).17 7.3.1 General .17 7.3.2 IECTC 57Physical view hierarchy.18 7.4 The IECTC 57Eventing View (normative) .20 7.4.1 General .20 7.4.2 IECTC 57EventingView properties20 8 Context supp
18、ort (normative)21 Annex A (informative) TC 57 Views discussion .22 Annex B (informative) Proxy architecture27 Annex C (informative) The IEC 61970 services and mapping IEC 61968 verbs28 Bibliography35 Figure 1 DAF resource identifiers model.8 Figure 2 GDA extended resource identifiers model .10 Figur
19、e 3 Resource descriptions 11 Figure 4 Resource descriptions:SimpleValue 12 Figure 5 Fictitious information model 14 Figure 6 Fictitious populated model displayed in tree 14 Figure 7 IECTC 57Views 15 Figure 8 Example TC 57 PhysicalView (informative) .16 Figure 9 Example IECTC 57EventingView (informat
20、ive) 16 Annex ZA (normative) Normative references to international publications with their corresponding European publications 36 BS EN 61970-402:2008 3 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIFigure A.1 Non-CIM-compliant example of a full m
21、esh network of object classes and instances 22 Figure A.2 Non-CIM-compliant example of traditional view of utility data .23 Figure A.3 Non-CIM-compliant example of customer data within a network view .23 Figure A.4 Non-CIM-compliant example of a full mesh view 24 Figure A.5 Subscribing to data using
22、 share path information .25 Figure A.6 TC 57 View used as a subscription topic tree.26 Table 1 DAF resource identifiers operations .9 Table 2 GDA extended resource identifiers operations10 Table 3 DAF resource description iterator.12 Table 4 Format of view version.17 Table 5 First level associations
23、 used in the TC 57PhysicalView 18 Table 6 Second level associations used in the TC 57PhysicalView18 Table 7 Third level associations used in the TC 57PhysicalView .19 Table 8 Fourth level associations used in the TC 57PhysicalView .19 Table 9 Fifth level associations used in the TC 57PhysicalView 19
24、 Table 10 Format of TC 57PhysicalView properties 20 Table 11 Format of TC 57EventingView properties21 Table C.1 Mapping IEC 61968 verbs to IEC 61970 services 30 BS EN 61970-402:2008 4 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIINTRODUCTION This
25、 standard is one of the IEC 61970 series parts that define an application program interface (API) for utility operational systems. This standard is based upon the work of the Electric Power Research Institute (EPRI) Control Center API (CCAPI) research project (RP-3654-1). The IEC 61970-4xx series sp
26、ecifies a set of interfaces that a component (or application) should implement to be able to exchange information with other components and/or access publicly available data in a standard way. The IEC 61970-4xx series component interfaces describe the specific event types and message contents that c
27、an be used by applications independent of any particular component technology. The implementation of these messages using a particular component technology is described in the IEC 61970-5xx series of documents. Thus, IEC 61970-4xx documents describe a Platform Independent Model (PIM), while IEC 6197
28、0-5xx documents describe a Platform Specific Model (PSM). IEC 61970-402 contains API services that are considered to be foundational. As such, all the other parts in the IEC 61970-4xx series assume their existence. As a result, the services described in IEC 61970-402 are required for any component t
29、hat complies with the IEC 61970-4xx series. The component interface specifications refer to entity objects for the power system domain that are defined in the IEC 61970-3xx series: Common Information Model (CIM). This standard contains normative and informative text. Clauses are marked as normative
30、or informative. A subclause inherits its parent clauses label unless overridden by the lower level subclause label. BS EN 61970-402:2008 5 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-AP
31、I) Part 402: Common services 1 Scope This International Standard provides the base functionality considered necessary and common that is provided by neither the normative standards incorporated by reference nor the new APIs specified in the IEC 61970-403 to IEC 61970-449 1)generic interface standard
32、s. An application is expected to use the Common Services in conjunction with the generic interfaces. These application category independent interfaces include: IEC 61970-403: Generic Data Access (GDA) IEC 61970-404: High Speed Data Access (HSDA) IEC 61970-405: Generic Eventing and Subscription (GES)
33、 IEC 61970-407: Time Series Data Access (TSDA) To support these objectives, the Common Services are divided into three categories: a) Resource Identifiers A common way of identifying classes, class attributes, and object instances. b) Resource Description A common way of encoding values associated w
34、ith classes, class attributes, and object instances. c) Views A common way of presenting classes, class attributes, and object instances via hierarchies. IEC 61970-402 contains API services that are considered to be foundational. As such, all the other parts in the IEC 61970-4xx series assume their
35、existence. As a result, the services described in IEC 61970-402 are required for any component that complies with the IEC 61970-4xx series of standards. Though the target of this IEC standard includes the control center technical domain, common services encompass a general set of concepts that can b
36、e applied to many types of systems. Examples of these systems include: Distribution management systems Work or asset management systems Geographic information systems Outage management systems Other types of operational business systems. In recognition that the integration between applications in tw
37、o or more of these systems is often necessary, the intent of this specification is to address general common service requirements to the extent that they are common to different types of systems while effectively addressing the control center needs. _ 1)At this time, only parts 402 to 408 exist. Add
38、itional generic services beyond are not yet under consideration. BS EN 61970-402:2008 6 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSI2 Normative references The following referenced documents are indispensable for the application of this document.
39、 For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61970-1, Energy management system application program interface (EMS-API) Part 1: Guidelines and general requirements IEC 61970-2, Ener
40、gy management system application program interface (EMS-API) Part 2: Glossary IEC 61970-401, Energy management system application program interface (EMS-API) Part 401: Component interface specification (CIS) framework IEC 61970-403, Energy management system application program interface (EMS-API) Pa
41、rt 403: Component Interface Specification (CIS) Generic data access IEC 61970-404, Energy management system application program interface (EMS-API) Part 404: High Speed Data Access (HSDA) IEC 61970-405, Energy management system application program interface (EMS-API) Part 405: Generic Eventing and S
42、ubscription (GES) IEC 61970-407, Energy management system application program interface (EMS-API) Part 407: Time Series Data Access (TSDA) OMG, Utility Management System Data Access Facility, document formal/2002-11-08 3 Terms and definitions For the purposes of this document, the terms and definiti
43、ons given in IEC 61970-2 apply. NOTE Refer to International Electrotechnical Vocabulary, IEC 60050, for general glossary definitions. 4 Background This International Standard specifies Component Interface Specifications (CIS) for Energy Management Systems Application Program Interfaces (EMS-API). It
44、 specifies the interfaces that a component (or application) shall implement to be able to exchange information with other components (or applications) and/or to access publicly available data in a standard way (see IEC 61970-1 for an overview of these standards). The goal of the creation of this doc
45、ument is to improve the interoperability of control center applications and systems. This specification provides a mechanism for applications from independent suppliers to access IEC 61970 Common Information Model (CIM) data using a common Application Program Interface (API) for the purpose of suppl
46、ementary processing, storage, or display. IEC 61970-401, CIS Framework, provides an overview of the CIS documents in the IEC 61970-4xx series. It explains the separation of these specifications into two major groups. One group of standards, IEC 61970-402 to IEC 61970-449, defines a set of generic ap
47、plication independent services that a component shall use for exchanging information with another component or for accessing public data. However, as the generic interfaces do not specify what specific data is exchanged, interoperability between products using IEC 61970-402 to IEC 61970-449 is not g
48、uaranteed. The other group, IEC 61970-450 to IEC 61970-499, defines the information content conveyed using the generic services that a particular component or system exchanges with other components. While IEC 61970-402 to IEC 61970-449 specify BS EN 61970-402:2008 7 Licensed Copy: Wang Bin, ISO/EXCH
49、ANGE CHINA STANDARDS, 06/01/2009 01:14, Uncontrolled Copy, (c) BSIapplication category independent message exchange mechanisms, IEC 61970-450 to IEC 61970-499 specify application category dependent CIM derived message contents. The IEC 61970-4xx series of documents describes the specific event types and message contents that shall be used by applications independent of any particular component technology. The implementation of these mess