1、BSI Standards PublicationEnergy performance of lamp controlgearPart 3: Controlgear for halogen lamps and LED modules Method of measurement to determine the efficiency of the controlgearBS EN 62442-3:2014National forewordThis British Standard is the UK implementation of EN 62442-3:2014. It isidentica
2、l to IEC 62442-3:2014.The UK participation in its preparation was entrusted by TechnicalCommittee CPL/34, Lamps and Related Equipment, to SubcommitteeCPL/34/3, Auxiliaries for lamps.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does
3、 not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 78753 9ICS 29.140.99Compliance with a British Standard cannot confer immunity fromlegal o
4、bligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62442-3:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62442-3 July 2014 IC
5、S 29.140.99 English Version Energy performance of lamp controlgear - Part 3: Controlgear for halogen lamps and LED modules - Method of measurement to determine the efficiency of the controlgear (IEC 62442-3:2014) Performance nergtique des appareillages de lampes - Partie 3: Appareillage de lampes ha
6、logne et modules de DEL - Mthode de mesure pour la dtermination du rendement de lappareillage (CEI 62442-3:2014) Energieeffizienz von Lampenbetriebsgerten - Teil 3: Betriebsgerte fr Halogenlampen und LED-Module - Messverfahren zur Bestimmung des Wirkungsgrades des Betriebsgertes (IEC 62442-3:2014) T
7、his European Standard was approved by CENELEC on 2014-05-29. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical r
8、eferences concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility
9、of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former
10、 Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical
11、 Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN
12、62442-3:2014 E BS EN 62442-3:2014EN 62442-3:2014 - 2 - Foreword The text of document 34C/1077/FDIS, future edition 1 of IEC 62442-3, prepared by SC 34C “Auxiliaries for lamps“, of IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 624
13、42-3:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-03-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow)
14、 2017-05-29 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62442-3:2014
15、 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60357 NOTE Harmonized as EN 60357. IEC 62384 NOTE Harmonized as EN 62384. IEC 62442-1:2011 NOTE Harmonized as EN
16、62442-1:2011 (not modified). IEC 62442-2: NOTE Harmonized as EN 62442-2:2014 (not modified). BS EN 62442-3:2014- 3 - EN 62442-3:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, ar
17、e normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modif
18、ied by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61047 2004 DC or AC supplied electronic step-down
19、convertors for filament lamps - Performance requirements EN 61047 2004 IEC 61347-1 (mod) 2007 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 2008 +A1 2010 +A1 2011 +A2 2012 +A2 2013 IEC 61347-2-2 - Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied
20、electronic step-down convertors for filament lamps EN 61347-2-2 - IEC 61347-2-13 - Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules EN 61347-2-13 - IEC 61558-1 - Safety of power transformers, power supplies, reactors and similar p
21、roducts - Part 1: General requirements and tests EN 61558-1 - IEC 61558-2-6 - Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporati
22、ng safety isolating transformers EN 61558-2-6 - IEC Guide 115 2007 Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector - - BS EN 62442-3:2014 2 IEC 62442-3:2014 IEC 2014 CONTENTS 1 Scope 5 2 Normative references . 5 3 Terms and definitions 6 4
23、 General . 8 4.1 Applicability 8 4.2 General notes on test . 8 4.3 Controllable controlgear . 8 4.4 Measurement uncertainty . 8 4.5 Sampling of controlgear for testing . 8 4.6 Number of samples 8 4.7 Power supply 9 4.8 Supply voltage waveform 9 4.9 Substitution load 9 4.10 Thermocouple and temperatu
24、re indicator 9 4.11 Instrument accuracy . 10 4.12 Measuring circuits 10 4.13 Multi-rated voltage controlgear . 10 4.14 Multi-power controlgear 10 5 Method of measurement and calculation of the efficiency of controlgear (transformer, convertor) for tungsten halogen lamps and for LED modules . 11 5.1
25、Measurement setup: input and output power . 11 5.2 Efficiency calculation for magnetic (transformer) and electronic (convertor) controlgear . 12 5.3 Measurement setup: input power in off mode 12 5.4 Standby power measurement of convertor electronic controlgear . 13 Bibliography 14 Figure 1 Power los
26、ses measurement setup for magnetic controlgear (transformer) and input and output power measurement setup for convertor (electronic controlgear) 11 Figure 2 Input power measurement setup for magnetic controlgear (transformer) and for convertor (electronic controlgear) . 12 Figure 3 Measurement setup
27、 of the standby power of convertor electronic controlgear 13 Table 1 Typical nominal electricity supply details for some regions 9 BS EN 62442-3:2014IEC 62442-3:2014 IEC 2014 5 ENERGY PERFORMANCE OF LAMP CONTROLGEAR Part 3: Controlgear for halogen lamps and LED modules Method of measurement to deter
28、mine the efficiency of the controlgear 1 Scope This part of the IEC 62442 series defines a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules. Also a calculation method of the efficien
29、cy for the mentioned controlgear for halogen lamps and LED modules is defined. This part of IEC 62442 applies to electrical controlgear lamp circuits comprised solely of the controlgear and of the lamp(s). For multipurpose power supplies only the lighting part will be considered. NOTE 1 Requirements
30、 for testing individual controlgear during production are not included. It specifies the measurement method for the total input power, the standby power and the calculation method of the controlgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with haloge
31、n lamps and LED modules. This part of IEC 62442 does not apply to: controlgear which form an integral part of lamps; controlgear circuits with capacitors connected in series; controllable wire-wound electromagnetic controlgear. 2 Normative references The following documents, in whole or in part, are
32、 normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61047:2004, DC or AC. supplied electronic step-down
33、convertors for filament lamps Performance requirements IEC 61347-1:2007, Lamp controlgear Part 1: General and safety requirements Amendment 1:2010 Amendment 2:2012 IEC 61347-2-2, Lamp controlgear Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament
34、 lamps IEC 61347-2-13, Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules IEC 61558-1, Safety of power transformers, power supplies, reactors and similar products Part 1: General requirements and tests BS EN 62442-3:2014 6 IEC 62442-3
35、:2014 IEC 2014 IEC 61558-2-6, Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers IEC Guide 115:200
36、7, Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector 3 Terms and definitions For the purpose of this document, the following terms and definitions apply. 3.1 nominal value suitable approximate quantity value used to designate or identify a c
37、omponent, device or equipment SOURCE: IEC 62442-1:2011, 3.1 3.2 rated value quantity value for specified operating conditions of a component, device or equipment The value and conditions are specified in the relevant standard or assigned by the manufacturer or responsible vendor SOURCE: IEC 62442-1:
38、2011, 3.3, modified The note has been removed. 3.3 controlgear one or more component between supply and one or more lamps which may serve to transform the supply voltage, limit the current of lamp(s) to the required value, provide starting voltage and preheating current, prevent cold starting, corre
39、ct power factor or reduce radio interference SOURCE: IEC 62442-1:2011,3.4 3.4 electromagnetic controlgear controlgear which by means of inductance, or a combination of inductance and capacitance, serves mainly to limit the current of lamp(s) to the required value Frequency of the lamp controlgear is
40、 the same as supply frequency SOURCE: IEC 62442-1:2011, 3.5 3.5 magnetic transformer transformer magnetic controlgear which transform the supply voltage to operate lamp(s) with the same frequency as supply frequency at the lamps rated voltage 3.6 electronic controlgear, A.C. and/or D.C. supplied ele
41、ctronic circuit including stabilizing elements for operating one or more filament lamp(s) or one or more LED module(s) BS EN 62442-3:2014IEC 62442-3:2014 IEC 2014 7 3.7 electronic step-down convertor convertor unit inserted between the supply and one or more tungsten-halogen or other filament lamps
42、which serves to supply the lamp(s) with its (their) rated voltage, generally at high frequency Note 1 to entry: The unit may consist of one or more separate components and may include means for dimming, correcting the power factor and suppressing radio interference. SOURCE: IEC 61347-2-2:2011, 3.1,
43、modified Additional information has been transferred to a note to entry. 3.8 electronic controlgear for LED modules convertor unit inserted between the supply and one or more LED modules which serves to supply the LED module(s) with its (their) rated voltage or rated current. The unit may consist of
44、 one or more separate components and may include means for dimming, correcting the power factor and suppressing radio interference 3.9 LED module unit supplied as a light source, which in addition to one or more LEDs may contain further components, e.g. optical, electrical, mechanical and/or electro
45、nic 3.10 controlgear lamp circuit electrical circuit, or part thereof, normally built in a luminaire, consisting of the controlgear and lamp(s) SOURCE: IEC 62242-1:2011,3.8 3.11 standby power average power consumption of a controlgear when subjected to standby mode Note 1 to entry: Unit: W. 3.12 sta
46、ndby mode mode relevant for those controlgear which are permanently connected to the mains, where the lamp(s) are switched off via a control signal, not including failed lamp(s) SOURCE: IEC 62242-2:, 3.8, modified The note has been removed. 3.13 total input power total power supplied to the controlg
47、ear lamp circuit measured at rated input voltage SOURCE: IEC 62242-1:2011, 3.14, modified The sentence “The rated power specified is related to a specific ballast lumen factor (BLF).“ has been removed. 3.14 off mode mode relevant for those controlgear which are permanently connected to the mains, wh
48、ere the lamp(s) are switched off via a switch on the output circuit of the controlgear, not including failed lamp(s) BS EN 62442-3:2014 8 IEC 62442-3:2014 IEC 2014 3.15 controlgear efficiency, (CG)ratio between the lamp power (controlgear output power) and the input power of the controlgear lamp cir
49、cuit with possible sensors, network connections and other auxiliary loads disconnected 4 General 4.1 Applicability The measurement and calculation methods of this standard shall only be used for magnetic transformer which conforms to IEC 61558-1 and IEC 61558-2-6 or for electronic convertor which conforms to IEC 61347-1 and IEC 61347-2-2 or for electronic controlgear for LED modules which conforms to IEC 61347-1 and IEC 61347-2-13. 4.2 General notes o