1、BSI Standards PublicationDigital load side transmissionlighting controlPart 1: Basic requirementsBS EN 62756-1:2015National forewordThis British Standard is the UK implementation of EN 62756-1:2015. It isidentical to IEC 62756-1:2015.The UK participation in its preparation was entrusted by Technical

2、Committee CPL/34, Lamps and Related Equipment, to SubcommitteeCPL/34/3, Auxiliaries for lamps.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible

3、 for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 76758 6ICS 29.140.99Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Polic

4、y and Strategy Committee on 31 August 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62756-1:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62756-1 July 2015 ICS 29.140.99 English Version Digital load side transmission lighting control - Part 1:

5、Basic requirements (IEC 62756-1:2015) Commande dclairage de transmission ct numrique (DLT) - Partie 1 : Exigences de base (IEC 62756-1:2015) Digitale lastleitungsseitige Schnittstelle zur Beleuchtungssteuerung (DLT) - Teil 1: Grundanforderungen (IEC 62756-1:2015) This European Standard was approved

6、by CENELEC on 2015-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national

7、standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own la

8、nguage and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Fr

9、ance, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de N

10、ormalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 62756-1:2015 E BS EN 62756-1:2015EN

11、 62756-1:2015 2 European foreword The text of document 34C/1054/CDV, future edition 1 of IEC 62756-1, prepared by SC 34C “Auxiliaries for lamps“ of IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62756-1:2015. The following dates a

12、re fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-04-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-07-01 Attention is drawn t

13、o the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62756-1:2015 was approved by CENELEC as a Eu

14、ropean Standard without any modification. BS EN 62756-1:2015EN 62756-1:2015 3 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indis

15、pensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the re

16、levant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60038 - IEC standard voltages EN 60038 - IEC 60364 series Low-voltage electrical installations HD 60364 s

17、eries BS EN 62756-1:2015 2 IEC 62756-1:2015 IEC 2015 CONTENTS FOREWORD . 5 INTRODUCTION . 7 1 Scope 8 2 Normative references 8 3 Terms and definitions 8 4 General description . 10 4.1 General . 10 4.2 Master-slave structure 10 4.3 Specification overview 10 5 General requirements 10 5.1 Voltage ratin

18、g . 10 5.2 Frequency rating . 11 5.3 Marking of control devices and control gear 11 6 Electrical specification . 11 6.1 General . 11 6.2 Wiring method . 12 6.3 Wiring diagram 12 6.4 Block diagram of the control gear 12 6.5 Block diagram of the control device . 13 6.6 Electrical characteristics in di

19、fferent periods of the mains waveform . 13 6.6.1 General . 13 6.6.2 Separation of the half-wave into time periods 14 6.6.3 Electrical characteristics of the supply period 14 6.6.4 Electrical characteristics of the operating period 19 6.6.5 Electrical characteristics of the data period 19 6.7 Data si

20、gnal voltage range and timing 23 6.8 Power up timing 23 6.9 Electrical characteristics during the off state of control gear 24 6.9.1 General . 24 6.9.2 Power controlled off state 24 6.9.3 Telegram controlled off state . 25 7 Data timing 25 7.1 General . 25 7.2 Information bit timing 25 7.3 Permissib

21、le frames . 25 8 Telegram structure 26 8.1 General . 26 8.2 Telegrams . 27 8.2.1 General . 27 8.2.2 Group number . 27 8.2.3 Telegram type . 27 8.2.4 Parity bit 27 8.2.5 Data for control of the control gear 27 9 Definition of telegram types . 27 9.1 Summary of telegram types 27 BS EN 62756-1:2015IEC

22、62756-1:2015 IEC 2015 3 9.2 Telegram type 0: Brightness . 28 9.3 Telegram type 1: Colour control 28 9.4 Telegram type 2: Colour temperature control 29 9.5 Telegram type 3 29 9.6 Telegram type 4 29 9.7 Telegram type 5: commissioning: Group number assignment 29 9.8 Telegram type 6: Manufacturer specif

23、ic . 30 9.9 Telegram type 7: extended telegram . 30 10 Method of operation . 30 10.1 General . 30 10.2 Brightness 31 10.2.1 General . 31 10.2.2 Response time . 31 10.2.3 Light output level . 31 10.2.4 Start-up . 31 10.3 Colour control . 31 10.3.1 General . 31 10.3.2 Colour (x, y) . 31 10.3.3 Respons

24、e time . 32 10.3.4 Colour gamut . 32 10.3.5 Start-up . 32 10.4 Colour temperature control . 33 10.4.1 General . 33 10.4.2 CCT (correlated colour temperature) . 33 10.4.3 Response time . 33 10.4.4 Start-up . 33 10.5 Telegram controlled group number assignment . 33 10.6 Manufacturer specific telegram

25、. 34 11 Test procedures 34 11.1 General . 34 11.2 Electrical characteristics tests . 35 11.2.1 General . 35 11.2.2 Test of control device 35 11.2.3 Test of control gear . 38 11.3 Test of data timing 41 11.4 Test of telegram structure . 41 11.4.1 Test of control device 41 11.4.2 Test of control gear

26、. 41 11.5 Test of telegram types 42 11.5.1 General . 42 11.5.2 Rejection of unsupported telegram types . 42 11.5.3 Test of telegram type 0: brightness 42 11.5.4 Test of telegram type 1: colour control . 42 11.5.5 Test of telegram type 2: colour temperature control . 43 11.5.6 Test of telegram type 5

27、: commissioning . 43 11.5.7 Test of telegram type 6: manufacturer specific . 43 11.6 Test of method of operation 43 11.6.1 General . 43 11.6.2 Group number operation 43 BS EN 62756-1:2015 4 IEC 62756-1:2015 IEC 2015 Annex A (informative) Examples of procedures for telegram controlled group number co

28、mmissioning . 47 A.1 Telegram controlled group number assignment of a new system . 47 A.2 Telegram controlled group number assignment of replacement control gear . 47 A.3 Telegram controlled changing of group numbers . 48 Figure 1 Example wiring diagram . 12 Figure 2 Example of block diagram of cont

29、rol gear . 13 Figure 3 Example of block diagram of control device 13 Figure 4 Time periods of each half-wave 14 Figure 5 Timing of supply period 15 Figure 6 Timing data period . 20 Figure 7 Rise time and fall time at the control interface 23 Figure 8 Transmission of “start of telegram” . 25 Figure 9

30、 Transmission of first bit 0, second bit 0 25 Figure 10 Transmission of first bit 0, second bit 1 26 Figure 11 Transmission of first bit 1, second bit 0 26 Figure 12 Transmission of first bit 1, second bit 1 26 Figure 13 Brightness telegram . 28 Figure 14 Colour control telegram 28 Figure 15 Colour

31、temperature telegram 29 Figure 16 Group number assignment telegram . 29 Figure 17 Manufacturer specific telegram. 30 Figure 18 The CIE 1931 colour space chromaticity diagram . 32 Figure 19 Test Circuit for testing the Control Device 35 Figure 20 Test Circuit for testing the Control Gear . 38 Figure

32、21 Voltage applied to control gear for test procedure 39 Table 1 Nominal mains voltage 100 V, frequency 50 Hz or 60 Hz . 17 Table 2 Nominal mains voltage 120 V; frequency 50 Hz or 60 Hz . 17 Table 3 Nominal mains voltage 200 V; frequency 50 Hz or 60 Hz . 18 Table 4 Nominal mains voltage 230 V; frequ

33、ency 50 Hz or 60 Hz . 18 Table 5 Nominal mains voltage 277 V; frequency 50 Hz or 60 Hz . 19 Table 6 Nominal mains voltage 100 V; frequency 50 Hz or 60 Hz . 21 Table 7 Nominal mains voltage 120 V; frequency 50 Hz or 60 Hz . 21 Table 8 Nominal mains voltage 200 V; frequency 50 Hz or 60 Hz . 21 Table 9

34、 Nominal mains voltage 230 V; frequency 50 Hz or 60 Hz . 22 Table 10 Nominal mains voltage 277 V; frequency 50 Hz or 60 Hz . 22 Table 11 Electrical characteristics of the data signal 23 Table 12 Currents and Voltages for control gear during the power controlled off state . 24 Table 13 Telegram types

35、 . 28 Table 14 Dimming characteristic 31 Table 15 Parameters for testing purposes 35 Table 16 Group number test telegram sequence 44 BS EN 62756-1:2015IEC 62756-1:2015 IEC 2015 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ DIGITAL LOAD SIDE TRANSMISSION LIGHTING CONTROL (DLT) Part 1: Basic requireme

36、nts FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in

37、 the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrust

38、ed to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the Internati

39、onal Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each

40、 technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

41、 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in thei

42、r national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessme

43、nt services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employee

44、s, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the pu

45、blication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the poss

46、ibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 62756-1 has been prepared by subcommittee 34C: Auxiliaries for lamps, of IEC technical committee

47、34: Lamps and related equipment. The text of this standard is based on the following documents: CDV Report on voting 34C/1054/CDV 34C/1081B/RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has bee

48、n drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts in the IEC 62756 series, published under the general title Digital load side transmission lighting control (DLT), can be found on the IEC website. BS EN 62756-1:2015 6 IEC 62756-1:2015 IEC 2015 The committee has decided

49、 that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. IMPORTANT The colour inside logo on the cover page of this publicatio