1、BSI Standards PublicationBS EN ISO 25745-3:2015Energy performance of lifts,escalators and moving walksPart 3: Energy calculation and classificationof escalators and moving walksBS EN ISO 25745-3:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN ISO25745-3:201
2、5.The UK participation in its preparation was entrusted to TechnicalCommittee MHE/4, Lifts, hoists and escalators.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. U
3、sers are responsible for its correctapplication. The British Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 82820 1ICS 91.140.90Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of
4、 theStandards Policy and Strategy Committee on 30 April 2015.Amendments issued since publicationDate Text affectedEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 25745-3 April 2015 ICS 91.140.90 English Version Energy performance of lifts, escalators and moving walks - Part 3: Energy calcul
5、ation and classification of escalators and moving walks (ISO 25745-3:2015) Performance nergtique des ascenseurs, escaliers mcaniques et trottoirs roulants - Partie 3: Calcul nergtique et classification des escaliers mcaniques et trottoirs roulants (ISO 25745-3:2015) Energieeffizienz von Aufzgen, Fah
6、rtreppen und Fahrsteigen - Teil 3: Energieberechnung und Klassifizierung von Fahrtreppen und Fahrsteigen (ISO 25745-3:2015) This European Standard was approved by CEN on 22 November 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giv
7、ing this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three off
8、icial versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies o
9、f Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
10、 Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide f
11、or CEN national Members. Ref. No. EN ISO 25745-3:2015 EBS EN ISO 25745-3:2015EN ISO 25745-3:2015 (E) 3 Foreword This document (EN ISO 25745-3:2015) has been prepared by Technical Committee ISO/TC 178 “Lifts, escalators and moving walks” in collaboration with Technical Committee CEN/TC 10 “Lifts, esc
12、alators and moving walks” the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2015, and conflicting national standards shall be withdrawn at the late
13、st by October 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national st
14、andards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
15、 Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 25745-3:2015 has been approved by CEN as EN ISO 25745-3:2015 without any modification. BS EN ISO 25745-3:2015ISO 25745
16、-3:2015(E)Foreword ivIntroduction v1 Scope . 12 Normative references 13 Terms, definitions and symbols 13.1 Terms and definitions . 23.2 Symbols (in alphabetical order) . 24 Estimation of energy consumption . 45 Energy performance classification 55.1 General . 55.2 Classification of the reference po
17、wer consumption . 55.3 Calculation or measurement of the power consumption of the specified unit . 65.4 Calculation of the energy performance ratio 65.5 Calculation of the reference operation mode performance ratio 75.6 Energy performance classification 76 Reporting 86.1 Documentation of the energy
18、assessment 86.2 Example . 8Annex A (informative) Calculation of energy consumption 10 ISO 2015 All rights reserved iiiContents PageBS EN ISO 25745-3:2015ISO 25745-3:2015(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO mem
19、ber bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmen
20、tal and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance
21、are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is
22、 drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or
23、 on the ISO list of patent declarations received (see www.iso.org/patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity asses
24、sment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible for this document is ISO/TC 178, Lifts, escalators and moving walks.ISO 25745 consists of the followi
25、ng parts, under the general title Energy performance of lifts, escalators and moving walks: Part 1: Energy measurement and verification Part 2: Energy calculation and classification for lifts (elevators) Part 3: Energy calculation and classification for escalators and moving walksiv ISO 2015 All rig
26、hts reservedBS EN ISO 25745-3:2015ISO 25745-3:2015(E)IntroductionThis International Standard has been prepared in response to the rapidly increasing need to ensure and to support the efficient and effective use of energy. This International Standard providesa) a method to estimate energy consumption
27、 of escalators and moving walks on a daily and an annual basis for escalators and moving walks,b) a method for energy classification of new, existing, or modernized escalators and moving walks,c) guidelines for reducing energy consumption that can be used to support building and environmental and en
28、ergy classification systems.This International Standard is intended to be a reference for the following parties: building developers/owners to evaluate the energy consumption of escalators and moving walks; building owners and service companies when modernising installations including reduction of e
29、nergy consumption; the installers and maintenance providers of escalators and moving walks; consultants and architects involved in specification of escalators and moving walks; inspecting authorities and other third parties providing energy classification services.The total energy consumption over t
30、he entire life cycle of escalators and moving walks consists of the energy to manufacture, install, operate, and dispose of the lifts. However, for the purpose of this International Standard, only operating energy (running and standby) performance is considered.In the preparation of this Internation
31、al Standard, Technical Committee ISO/TC 178/ WG 10 has initiated extensive research, which included the measuring and modelling of over 300 typical escalator and moving walk installations. The results of this research have been used to provide the numerical values shown in Table 3 and Table A.3.This
32、 International Standard is suitable for national/regional jurisdictional energy performance purposes. ISO 2015 All rights reserved vBS EN ISO 25745-3:2015BS EN ISO 25745-3:2015Energy performance of lifts, escalators and moving walks Part 3: Energy calculation and classification of escalators and mov
33、ing walks1 ScopeThis part of ISO 25745 specifiesa) generic tools for estimating energy consumption of escalators and moving walks, andb) a consistent method for energy performance classification of existing, modernized, or new escalators and moving walks.This part of ISO 25745 considers the energy p
34、erformance during the operational portion of the life cycle of escalators and moving walks. It does not cover energy consumption and classification of the ancillary equipment, such as the following:a) lighting with the exception of comb plate lighting, step gap lighting, and traffic light;NOTE 1 Com
35、b plate lighting, step gap lighting, and traffic light are considered essential for the operation of the equipment and are therefore not defined as ancillary equipment.b) cooling and heating and machine room ventilation;c) alarm devices and emergency battery supplies equipment, etc.;d) environmental
36、 conditions;e) consumption through the power sockets.NOTE 2 There can be other electrical loads not associated with the escalator or moving walk, which shall not be included.This part of ISO 25745 considers all escalators and inclined moving walks up to a rise of 8 m and horizontal moving walks with
37、 a length up to 60 m.NOTE This represents about 85 % of worldwide installed units.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undat
38、ed references, the latest edition of the referenced document (including any amendments) applies.ISO 25745-1, Energy performance of lifts, escalators and moving walks Part 1: Energy measurement and verification3 Terms, definitions and symbolsFor the purposes of this document, the following terms, def
39、initions and symbols (see Table 1) apply. INTERNATIONAL STANDARD ISO 25745-3:2015(E) ISO 2015 All rights reserved 1BS EN ISO 25745-3:2015ISO 25745-3:2015(E)3.1 Terms and definitions3.1.1ancillary energyenergy used by the ancillary equipment3.1.2ancillary equipmentequipment such as lighting, fans, he
40、ating, alarm devices, emergency battery supplies, etc.3.1.3auto start conditioncondition when escalator/moving walk is stationary and powered up and ready to start initiated by passenger detection3.1.4energypower consumed over time3.1.5load conditioncondition when escalator/moving walk is running wi
41、th one or more passengers3.1.6no load conditioncondition when escalator/moving walk is running at nominal speed without passengers3.1.7nominal speed of escalator/moving walkspeed in the direction of the moving steps, pallets, or the belt, when operating the equipment under no load condition (i.e. wi
42、thout persons), stated by the manufacturer as that for which the escalator or moving walk has been designed3.1.8power-off conditionpower supply to the unit is turned off by the main switch, e.g. during the night3.1.9running-in periodrequired time to get mechanical components to best performance3.1.1
43、0slow speed conditioncondition when escalator/moving walk is running at reduced speed without passengers3.1.11standby conditioncondition when the escalator/moving walk is stationary and powered on and can be started by authorized personnel3.2 Symbols (in alphabetical order)Table 1 Symbols and abbrev
44、iationsSymbol Term Definition Unit AssumptionsA Length depending part of handrail drag force normalized to horizontalN/m B The constant part of handrail drag force normalized to horizontalN 2 ISO 2015 All rights reservedBS EN ISO 25745-3:2015ISO 25745-3:2015(E)Symbol Term Definition Unit Assumptions
45、C Constant part of step band reversal drag forcekN CF Correction factorCorrection factor for efficiency applied to units in downward direc-tion- Number of users/N day 10 000 or non-regenerative drive technology: CF = 0N/day 10 000: CF = 0,5D Pitch length of step or pallet m Default value = 0,405Eanc
46、illaryEnergy Total energy consumption of ancil-lary systemkWh Eauto startEnergy Energy consumption in auto start conditionkWh EloadEnergy Energy consumption due to the transport of passengerskWh Negative for down running;Positive for up runningEmainEnergy Total energy consumption of unit w/o ancilla
47、ry energykWh Eno loadEnergy Energy consumption under no load conditionkWh Eslow speedEnergy Energy consumption in slow speed conditionkWh EstandbyEnergy Energy consumption in standby conditionkWh EtotalEnergy Total energy consumption of unit incl. Ancillary energykWh H Rise Vertical distance between
48、 the upper and lower finished floor levelsm L Length Distance between the comb intersec-tion linesm m Weight of passengerAverage weight of passenger kg 75 kg/personmchainMass Mass of chain band per meter kg/m mSB/PBMass Mass of a step/pallet kg N Number of passengersNumber of transported persons in
49、observation period- Pno_load_controlPower Total reference power consumption to operate no load conditionkW Pno_load_handrailPower Total reference power consump-tion of a handrail system in no load conditionkW Pno_load_refPower Total reference power consumption in no load conditionkW Pno_load_specPower Total calculated or measured power consumption of the specified unit in no load conditionkW PstandbyPower Total reference power consumption to operate in standby conditionkW Table 1 (continued) ISO 2015 All rights reserved 3BS EN ISO 25745-3