BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf

上传人:amazingpat195 文档编号:581941 上传时间:2018-12-15 格式:PDF 页数:14 大小:1.24MB
下载 相关 举报
BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf_第1页
第1页 / 共14页
BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf_第2页
第2页 / 共14页
BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf_第3页
第3页 / 共14页
BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf_第4页
第4页 / 共14页
BS EN ISO 27587-2009 Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries《皮革 化学试验 加工辅助设备中游离甲醛的测定》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS EN ISO27587:2009ICS 59.140.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDLeather Chemicaltests Determinationof the freeformaldehyde inprocess auxiliaries(ISO 27587:2009)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled

2、Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 31January 2010 BSI 2010ISBN 978 0 580 62288 5Amendments/corrigenda issued since publicationDate CommentsBS EN ISO 27587:2009National forewordThis British Standard is the UK implemen

3、tation of EN ISO 27587:2009. The UK participation in its preparation was entrusted to TechnicalCommittee TCI/69, Footwear, leather and coated fabrics.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the

4、necessary provisionsof a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD NORME EUROPENNE E

5、UROPISCHE NORM EN ISO 27587 October 2009 ICS 59.140.30 English Version Leather - Chemical tests - Determination of the free formaldehyde in process auxiliaries (ISO 27587:2009) Cuir - Essais chimiques - Dosage du formaldhyde libre dans les auxiliaires de traitement (ISO 27587:2009) Leder - Chemische

6、 Prfverfahren - Bestimmung des Gehalts an freiem Formaldehyd in Hilfsmitteln fr die Lederherstellung (ISO 27587:2009) This European Standard was approved by CEN on 26 September 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving t

7、his European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official version

8、s (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, B

9、ulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STAND

10、ARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 27587:2009: ELicensed Copy: Wang Bin, ISO/EXCHAN

11、GE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009EN ISO 27587:2009 (E) 3 Foreword This document (EN ISO 27587:2009) has been prepared by Technical Committee CEN/TC 289 “Leather”, the secretariat of which is held by UNI, in collaboration with the International Union

12、 of Leather Technologists and Chemists Societies (IULTCS). This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2010, and conflicting national standards shall be withdrawn at the latest by April

13、2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organi

14、zations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Rom

15、ania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009ISO 27587:2009(E) IULTCS/IUC 26:2009(E) ISO 2009 All rights reserved iiiContents Page Foreword iv 1 Scop

16、e . 1 2 Normative references . 1 3 Terms and definitions. 1 4 Principle. 1 5 Reagents 1 6 Apparatus and materials 2 7 Methods . 3 7.1 Outline of sample preparation system . 3 7.2 Sample preparation 3 8 HPLC conditions (recommendations) 4 9 Calibration . 4 10 Calculation. 4 11 Checking reagents for a

17、bsence of formaldehyde . 5 12 Control of the procedure 5 13 Determination of formaldehyde in stock solutions. 5 14 Test report . 5 Annex A (informative) Reliability of the method . 6 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:20

18、09ISO 27587:2009(E) IULTCS/IUC 26:2009(E) iv ISO 2009 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO tec

19、hnical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closel

20、y with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft

21、International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this documen

22、t may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 27587/IUC 26 was prepared by the European Committee for Standardization (CEN) Technical Committee CEN/TC 289, Leather, in collaboration with the Chemical Tests Commission of th

23、e International Union of Leather Technologists and Chemists Societies (IUC Commission, IULTCS), in accordance with the Agreement on technical cooperation between ISO and CEN (Vienna Agreement). IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to furth

24、er the advancement of leather science and technology. IULTCS has three Commissions, which are responsible for establishing international methods for the sampling and testing of leather. ISO recognizes IULTCS as an international standardizing body for the preparation of test methods for leather. Lice

25、nsed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009INTERNATIONAL STANDARD ISO 27587:2009(E)IULTCS/IUC 26:2009(E) ISO 2009 All rights reserved 1Leather Chemical tests Determination of the free formaldehyde in process auxiliaries 1 Scope

26、This International Standard specifies a method for the determination of free formaldehyde in process auxiliaries for leather. The analytical result obtained according to this procedure is expressed in milligrams per kilogram (mg/kg) sample. The upper limit of quantification of the method is given by

27、 the capacity of the cartridge (total carbonyls 6 400 g/cartridge). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced doc

28、ument (including any amendments) applies. ISO 3696, Water for analytical laboratory use Specification and test methods 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 free formaldehyde formaldehyde that is released under dynamic conditions wh

29、en the sample is heated in an inert dry atmosphere 4 Principle The sample is heated in an inert atmosphere for a defined period of time. The released formaldehyde is captured and derivatized using a dinitrophenylhydrazine (DNPH) cartridge. The analyte is eluted with acetonitrile and analysed by high

30、-performance liquid chromatography (HPLC) using a UV detector. 5 Reagents Use only reagents of recognized analytical grade, unless otherwise stated. 5.1 Sulfuric acid, 3 mol/l. 5.2 Sodium hydroxide, 2 mol/l. 5.3 Sodium thiosulfate, 0,1 mol/l. 5.4 Iodine solution, 0,05 mol/l, i.e. 12,68 g iodine per

31、litre of water. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009ISO 27587:2009(E) IULTCS/IUC 26:2009(E) 2 ISO 2009 All rights reserved5.5 Starch solution, 1 g/100 ml water. 5.6 Formaldehyde hydrazone solution. 5.7 Calibration sta

32、ndards. Prepare solutions by adequate dilution of the formaldehyde hydrazone solution (5.6). 5.8 Formaldehyde solution, approximately 37 % mass fraction. 5.9 Formaldehyde stock solution S1, prepare by pipetting 5 ml of formaldehyde solution (5.8) in a 1 000 ml volumetric flask and fill to the mark w

33、ith distilled water. 5.10 Formaldehyde solution S2 in an adequate dilution for procedure control e.g. 2,5 ml of the formaldehyde stock solution S1 (5.9) in a 100 ml volumetric flask, fill up with distilled water. The concentration of this solution should be adapted to ensure that the formaldehyde co

34、ntent is in the middle of the calibrated range. 5.11 Distilled water, quality 2 according to ISO 3696. 5.12 2,4-Dinitrophenylhydrazine cartridges (DNPH cartridges), suitable for fixing a total of 6 400 g of carbonyls per cartridge. For lower quantities of free formaldehyde, a smaller capacity cartri

35、dge can be used. It is recommended that the cartridge have an excess capacity of at least 20 % more than the predicted formaldehyde amount. 5.13 Acetonitrile, HPLC grade. 5.14 Water, HPLC grade. 6 Apparatus and materials Usual laboratory apparatus is required and, in particular, the following. 6.1 T

36、hermostatic oil bath with stirring facilities, capable of maintaining a constant temperature of (90 3) C. The oil bath shall be deep enough to allow the U-tube to be dipped in up to the side tubing. 6.2 Silicone oil, suitable for oil bath (6.1). 6.3 Nitrogen, purity 4,6. 6.4 U-tube, calcium chloride

37、 tube, U-shaped, with two stopcocks, leg length 150 mm. 6.5 Flow meter. 6.6 Silicone tubing. 6.7 Syringe filters, 0,45 m, regenerated cellulose. 6.8 Sea sand, purified by acid and calcined; quality grade GR for analysis. 6.9 Polytetrafluoroethylene (PTFE) stopcock grease, free of formaldehyde. 6.10

38、HPLC equipped with a UV detector. 6.11 HPLC column, of the RP-C18 type. 6.12 Hair dryer. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009ISO 27587:2009(E) IULTCS/IUC 26:2009(E) ISO 2009 All rights reserved 37 Methods 7.1 Outline

39、of sample preparation system See Figure 1. Key 1 gas tank 2 flow meter 3 DNPH cartridge 4 HPLC Figure 1 Schematic outline of sample preparation system 7.2 Sample preparation Prepare a sample preparation system as described in 7.1. Initially, the U-tube (6.4) and the DNPH cartridge (5.12) are disconn

40、ected from the sampling system. All the parts of the sample preparation system shall be dry prior to use. Purge the system for 15 min with nitrogen (6.3) at a flow rate of 500 ml/min. It is important that the analysis be carried out under an inert atmosphere. The purging step may be omitted before f

41、urther analyses if work is done without interruption. The sampling system is slightly pressurized; therefore, all stopcocks should be secured with joint clamps. Add 3 g to 4 g of sea sand (6.8) to the U-tube (6.4), ensuring that it is not blocked and that the nitrogen flow can be maintained. If this

42、 is not possible, use a larger diameter U-tube. Accurately weigh 0,5 g to 2 g of sample to the nearest 0,001 g into the U-tube. It may be necessary to reduce the amount of sample if it is in a liquid phase in order to diminish the likelihood of condensed water giving erroneous results. Apply a thin

43、layer of stopcock grease (6.9) to the joints of the U-tube. Introduce the U-tube into the system and purge for 5 min with nitrogen (6.3) at a flow rate of 500 ml/min. Reduce the flow rate to between 150 ml/min to 350 ml/min. Introduce the DNPH cartridge (5.12) into the system and place the U-tube in

44、to the oil bath (6.1) preheated to 90 C. Cover the cartridge and U-tube carefully with aluminum foil. During sampling, it may be necessary to readjust the flow rate. After 30 min, remove the U-tube containing the sample from the oil bath. Remove any condensate from the cartridge side of the tubing a

45、nd stopcock using a hair dryer (6.12). This step shall be carried out irrespective of whether condensate can be observed visually. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/05/2010 07:33, Uncontrolled Copy, (c) BSIBS EN ISO 27587:2009ISO 27587:2009(E) IULTCS/IUC 26:2009(E) 4 ISO 2009

46、 All rights reservedRemove the DNPH cartridge from the system and elute with small portions of acetonitrile (5.13) in a 10 ml volumetric flask. Make up to volume with acetonitrile. Carefully mix the solution by shaking and filter an aliquot for analysis using a syringe filter (6.7). Analyse the resu

47、lting filtrate by HPLC (6.10). It is recommended that the cartridges be removed from the refrigerator immediately prior to use. Experiments have shown that cartridges should be eluted within 3 days. 8 HPLC conditions (recommendations) Separation column: CC 250/4 Nucleosil 100-5 C18 HD1)with pre-colu

48、mn Flow rate: 0,8 ml/min Mobile phase: Solvent A, water Solvent B, acetonitrile Gradient: 55 % B linear to 95 % B in 20 min Column oven: 30 C UV detection: 360 nm Injection volume: 20 l 9 Calibration Calibration is carried out by means of an external standard in the range of 0,5 g/10 ml to 50 g/10 m

49、l. The working range is limited by the capacity of the cartridge. Prepare adequate dilutions (in acetonitrile) of the formaldehyde hydrazone solution (5.6). Calibration shall be done using at least six concentration levels. The calibration is effected through plotting a graph of the formaldehyde derivative peak area versus the concentration (g/10 ml). 10 Calculation Calculate the formaldehyde content (w) expressed in milligrams per kilogram (mg/kg) of sample being tested. Fwm=where is the concentration of formaldehyde obtain

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
  • AIIM MS10-1987 Method for Determining Adhesion of Protection Sheet to Aperture Adhesive of Unitized Microfilm Carrier (Aperture Card)《整个缩微胶片传送器的缝隙胶粘剂的保护片的粘性》.pdf AIIM MS10-1987 Method for Determining Adhesion of Protection Sheet to Aperture Adhesive of Unitized Microfilm Carrier (Aperture Card)《整个缩微胶片传送器的缝隙胶粘剂的保护片的粘性》.pdf
  • AIIM MS11-1987 Microfilm Jackets《缩微胶片.勘误表-1993年》.pdf AIIM MS11-1987 Microfilm Jackets《缩微胶片.勘误表-1993年》.pdf
  • AIIM MS111-1994 Micrographics - Standard Recommended Practice for Microfilming Printed Newspapers on 35mm Roll Microfilm《显微制图技术-在35mm卷轴胶片上缩微印制报纸的标准推荐实施规程》.pdf AIIM MS111-1994 Micrographics - Standard Recommended Practice for Microfilming Printed Newspapers on 35mm Roll Microfilm《显微制图技术-在35mm卷轴胶片上缩微印制报纸的标准推荐实施规程》.pdf
  • AIIM MS14-1996 Recommended Practice - Specifications for 16mm and 35mm Roll Microfilm《16mm与35mm缩微胶片防光片盘与片盘.技术规范》.pdf AIIM MS14-1996 Recommended Practice - Specifications for 16mm and 35mm Roll Microfilm《16mm与35mm缩微胶片防光片盘与片盘.技术规范》.pdf
  • AIIM MS15-2000 Dimensions and Operational Constraints for Single-Core Cartridge for 16 mm Processed Microfilm《16mm加工胶片的单芯盒操作限制和尺寸》.pdf AIIM MS15-2000 Dimensions and Operational Constraints for Single-Core Cartridge for 16 mm Processed Microfilm《16mm加工胶片的单芯盒操作限制和尺寸》.pdf
  • AIIM MS17-2001 Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use《信息和图像管理-缩微摄影术-循环的(流量)缩微胶卷的测试图表和指标.pdf AIIM MS17-2001 Information and Image Management - Micrographics - Rotary (Flow) Microfilm Camera Test Chart and Test Target - Descriptions and Use《信息和图像管理-缩微摄影术-循环的(流量)缩微胶卷的测试图表和指标.pdf
  • AIIM MS18-1992 Micrographics - Splices for Imaged Microfilm - Dimensions and Operational Constraints《缩微摄影术-图像胶片的拼接-尺寸和操作限制》.pdf AIIM MS18-1992 Micrographics - Splices for Imaged Microfilm - Dimensions and Operational Constraints《缩微摄影术-图像胶片的拼接-尺寸和操作限制》.pdf
  • AIIM MS19-1993 Standard Recommended Practice - Identification of Microforms《缩微版本的识别推荐规程》.pdf AIIM MS19-1993 Standard Recommended Practice - Identification of Microforms《缩微版本的识别推荐规程》.pdf
  • AIIM MS23-2004 PRODUCTION INSPECTION AND QUALITY ASSURANCE OF FIRST-GENERATION SILVER MICROFORMS OF DOCUMENTS《文件的第一代缩微银胶片的生产、检验和质量保证》.pdf AIIM MS23-2004 PRODUCTION INSPECTION AND QUALITY ASSURANCE OF FIRST-GENERATION SILVER MICROFORMS OF DOCUMENTS《文件的第一代缩微银胶片的生产、检验和质量保证》.pdf