1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 15202-1:2012Workplace air Determinationof metals and metalloids inairborne particulate matterby inductively coupled plasmaatomic emission spectrometryPart 1: SamplingBS IS
2、O 15202-1:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 15202-1:2012.It supersedes BS ISO 15202-1:2000 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/2, Work place atmospheres.A list of organizations r
3、epresented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 5
4、80 71178 7ICS 13.040.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2012.Amendments issued since publicationDate Text affectedBS ISO 15202-1:2012 ISO 20
5、12Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 1: SamplingAir des lieux de travail Dtermination des mtaux et mtallodes dans les particules en suspension dans lair par spectromtrie dmission atomique
6、 avec plasma couplage inductif Partie 1: chantillonnageINTERNATIONAL STANDARDISO15202-1Second edition2012-06-01Reference numberISO 15202-1:2012(E)BS ISO 15202-1:2012ISO 15202-1:2012(E)ii ISO 2012 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2012All rights reserved. Unless otherwise specified,
7、 no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase post
8、ale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 15202-1:2012ISO 15202-1:2012(E) ISO 2012 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope 12 Normative references . 13 Terms and definitions . 1
9、3.1 General definitions 23.2 Particle size fraction definitions 33.3 Sampling definitions . 44 Principle . 45 Requirement . 46 Sampling equipment . 56.1 Samplers 56.2 Filters 56.3 Sampling pumps 56.4 Flowmeter 66.5 Ancillary equipment 67 Occupational exposure assessment 77.1 General . 77.2 Personal
10、sampling 77.3 Static sampling 77.4 Selection of measurement conditions and measurement pattern . 78 Sampling method 88.1 Preliminary considerations . 88.2 Preparation for sampling . 98.3 Sampling position .108.4 Collection of samples . 118.5 Transportation 119 Documentation . 119.1 Sampling informat
11、ion . 119.2 Information to accompany the request for analytical services 12Annex A (informative) Sampler wall deposits .13Annex B (informative) Guidance on filter selection 15Annex C (informative) Temperature and pressure correction for the indicated volumetric flow rate . 17Bibliography .18BS ISO 1
12、5202-1:2012ISO 15202-1:2012(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interest
13、ed in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Co
14、mmission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technic
15、al committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shal
16、l not be held responsible for identifying any or all such patent rights.ISO 15202-1 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 2, Workplace atmospheres.This second edition cancels and replaces the first edition (ISO 15202-1:2000), which has been technically revised.
17、 The major changes in the second edition are as follows: definitions have been updated; a new Annex A has been added to provide guidance regarding sampler wall deposits.ISO 15202 consists of the following parts, under the general title Workplace air Determination of metals and metalloids in airborne
18、 particulate matter by inductively coupled plasma atomic emission spectrometry: Part 1: Sampling Part 2: Sample preparation Part 3: Analysisiv ISO 2012 All rights reservedBS ISO 15202-1:2012ISO 15202-1:2012(E)IntroductionThe health of workers in many industries is at risk through exposure by inhalat
19、ion of toxic metals and metalloids. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers exposure, and this is generally achieved by taking workplace air measurements. This part of ISO 15202 has been published in order t
20、o make available a method for making valid exposure measurements for a wide range of metals and metalloids in use in industry. It will be of benefit to: agencies concerned with health and safety at work; industrial hygienists and other public health professionals; analytical laboratories; industrial
21、 users of metals and metalloids and their workers, etc.This part of ISO 15202 specifies a generic sampling method for subsequent determination of the mass concentration of metals and metalloids in workplace air using inductively coupled plasma atomic emission spectrometry (ICP-AES). Samples obtained
22、 using the method described herein can also be subsequently analysed by other instrumental methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma mass spectrometry (ICP-MS).This part of ISO 15202 gives details of relevant International, European and National Standards wh
23、ich specify characteristics, performance requirements and test methods relating to sampling equipment. It augments guidance provided elsewhere on assessment strategy and measurement strategy, and specifies a method for collecting samples of airborne particulate matter for subsequent chemical analysi
24、s.Part 2 of ISO 15202 describes a number of procedures for preparing sample solutions for analysis by ICP-AES.Part 3 of ISO 15202 gives requirements and test methods for analysis of sample solutions by ICP-AES.It has been assumed in the drafting of this part of ISO 15202 that the execution of its pr
25、ovisions, and the interpretation of the results obtained, is entrusted to appropriately qualified and experienced people. ISO 2012 All rights reserved vBS ISO 15202-1:2012BS ISO 15202-1:2012Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled pla
26、sma atomic emission spectrometry Part 1: Sampling1 Scope1.1 This part of ISO 15202 specifies a method for collecting samples of airborne particulate matter for subsequent determination of metals and metalloids using inductively coupled plasma atomic emission spectrometry (ICP-AES). Samples obtained
27、using the method described herein can also be subsequently analysed for elemental composition by other instrumental methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma mass spectrometry (ICP-MS).1.2 The method is not applicable to the sampling of mercury, which is pre
28、sent in air in the vapour phase at ambient temperatures; inorganic compounds of metals and metalloids that are permanent gases, e.g. arsine (AsH3); or inorganic compounds of metals and metalloids that are present in the vapour phase at ambient temperatures, e.g. arsenic trioxide (As2O3).NOTE Althoug
29、h the method does not describe a means of collecting inorganic compounds of metals and metalloids that are present in the vapour phase, in most instances this is relatively easily achieved by using a back-up filter which has been pre-treated to trap the compound(s) of interest, e.g. a back-up paper
30、pad impregnated with sodium carbonate is suitable for collecting arsenic trioxide (see ISO 110412).1.3 The method is applicable to personal sampling of the inhalable or respirable fraction of airborne particles, as defined in ISO 7708, and to static sampling.2 Normative referencesThe following refer
31、enced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 7708:1995, Air quality Particle size fraction definitions for hea
32、lth-related samplingISO 15202-2, Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 2: Sample preparationISO 15202-3, Workplace air Determination of metals and metalloids in airborne particulate matter b
33、y inductively coupled plasma atomic emission spectrometry Part 3: AnalysisEN 13205, Workplace atmospheres Assessment of performance of instruments for measurement of airborne particle concentrations3 Terms and definitionsFor the purposes of this document, the following terms and definitions apply.IN
34、TERNATIONAL STANDARD ISO 15202-1:2012(E) ISO 2012 All rights reserved 1BS ISO 15202-1:2012ISO 15202-1:2012(E)3.1 General definitions3.1.1breathing zonespace around the workers face from which breath is taken3.1.2breathing zonehemisphere (generally accepted to be 0,3 m in radius) extending in front o
35、f the human face, centred on the midpoint of a line joining the ears; the base of the hemisphere is a plane through this line, the top of the head and the larynxNOTE 1 The definition is not applicable when respiratory protective equipment is used.NOTE 2 Adapted from EN 1540:20116.3.1.3chemical agent
36、any chemical element or compound, on its own or admixed as it occurs in the natural state or as produced, used, or released including release as waste, by any work activity, whether or not produced intentionally and whether or not placed on the marketCouncil Directive 98/24/EC13, Art. 2(a)3.1.4expos
37、ure exposure by inhalationsituation in which a chemical agent is present in air which is inhaled by a personNOTE Adapted from EN 1540:20116.3.1.5occupational exposure limit valuelimit valuelimit of the time-weighted average of the concentration of a chemical agent in the air within the breathing zon
38、e of a worker in relation to a specified reference periodCouncil Directive 98/24/EC13, Art. 2(d)EXAMPLES Threshold Limit Values(TLVs) established by the ACGIH14, Indicative Occupational Exposure Limit Values (IOELVs) promulgated by the European Commission12and national limit values. Information on n
39、ational limit values is available from the International Labour Organization (ILO)15and on the GESTIS database16.3.1.6measuring proceduremeasurement procedureset of operations, described specifically, for the sampling and analysis of chemical agents in airNOTE 1 A measuring procedure usually include
40、s preparation for sampling, sampling, transportation and storage, preparation of samples for analysis and analysis.NOTE 2 Adapted from EN 1540:20116.3.1.7operating timeperiod during which a sampling pump can be operated at specified flow rate and back pressure without recharging or replacing the bat
41、teryEN 123252 ISO 2012 All rights reservedBS ISO 15202-1:2012ISO 15202-1:2012(E)3.1.8reference periodspecified period of time for which the occupational exposure limit value of a chemical agent appliesNOTE 1 The reference period is usually 8 h for long-term measurements and 15 min for short-term mea
42、surements.NOTE 2 Examples for different reference periods are short-term and long-term limit values, such as those established by the ACGIH14.NOTE 3 Adapted from EN 1540:20116.3.1.9time-weighted average concentrationTWA concentrationconcentration of a chemical agent in the atmosphere, averaged over
43、the reference periodNOTE A more detailed discussion of TWA concentrations and their use can be found in Reference 14.3.1.10workplacedesignated area or areas in which the work activities are carried outEN 1540:201163.2 Particle size fraction definitions3.2.1inhalable conventiontarget specification fo
44、r sampling instruments when the inhalable fraction is of interestISO 7708:19953.2.2inhalable fractionmass fraction of total airborne particles that is inhaled through the nose and mouthISO 7708:1995NOTE The inhalable fraction depends on the speed and direction of air movement, on breathing rate and
45、other factors.3.2.3respirable conventiontarget specification for sampling instruments when the respirable fraction is of interestISO 7708:19953.2.4respirable fractionmass fraction of inhaled particles penetrating to the unciliated airwaysISO 7708:19953.2.5total airborne particlesall particles surrou
46、nded by air in a given volume of airISO 7708:1995NOTE Because all measuring instruments are size-selective to some extent, it is often impossible to measure the total concentration of airborne particles. ISO 2012 All rights reserved 3BS ISO 15202-1:2012ISO 15202-1:2012(E)3.3 Sampling definitions3.3.
47、1personal samplersampler, attached to a person, that collects airborne particles in the breathing zone to determine exposure to chemical agentsNOTE Adapted from EN 1540:20116.3.3.2personal samplingprocess of sampling carried out using a personal samplerEN 1540:201163.3.3air samplersamplerdevice for
48、separating chemical agents from the surrounding airNOTE 1 Air samplers are generally designed for a particular purpose, e.g. for sampling airborne particles.NOTE 2 Adapted from EN 1540:20116.3.3.4static samplerarea samplersampler, not attached to a person, that collects airborne particles at a parti
49、cular locationNOTE Adapted from EN 1540:20116.3.3.5static samplingarea samplingprocess of (air) sampling carried out using a static samplerEN 1540:201164 Principle4.1 Airborne particles containing metals and metalloids are collected by drawing a measured volume of air through a filter mounted in a sampler designed to collect an appropriate size fraction of airborne particles (see 8.1.1.1).4.2 The filter and collected sample are then treated to dissolve the