BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf

上传人:registerpick115 文档编号:584662 上传时间:2018-12-15 格式:PDF 页数:16 大小:188.62KB
下载 相关 举报
BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf_第1页
第1页 / 共16页
BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf_第2页
第2页 / 共16页
BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf_第3页
第3页 / 共16页
BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf_第4页
第4页 / 共16页
BS ISO 15227-2000 Optics and optical instruments - Microscopes - Testing of stereomicroscopes《光学和光学仪器 显微镜 立体可视显微镜的试验》.pdf_第5页
第5页 / 共16页
亲,该文档总共16页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS ISO 15227:2000 ICS 37.

2、020 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Optics and optical instruments Microscopes Testing of stereomicroscopesThis British Standard, having been prepared under the direction of the Sector Committee for Materials and Chemicals, was published under the authority of

3、the Standards Committee and comes into effect on 15 June 2000 BSI 06-2000 ISBN 0 580 34962 4 BS ISO 15227:2000 Amendments issued since publication Amd. No. Date Comments National foreword This British Standard reproduces verbatim ISO 15227:2000 and implements it as the UK national standard. The UK p

4、articipation in its preparation was entrusted to Technical Committee LBI/33, Microscopes, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK i

5、nterests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international publications referred to i

6、n this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract.

7、 Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the ISO title page, pages ii to iv, pages 1 to 9 and

8、 a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.Referencenumber ISO15227:2000(E) INTERNATIONAL STANDARD ISO 15227 Firstedition 2000-04-01 Opticsandopticalinstruments MicroscopesTestingof stereomicroscopes Optique et instruments doptique

9、Microscopes Essai des stromicroscopesISO15227:2000(E) ii ISO15227:2000(E)iii Contents Page Foreword.iv 1 Scope1 2 Normativereferences1 3 Termsanddefinitions.1 4 Accuracyoftesting1 5 Testconditions1 5.1 Totalvisualmagnification(M TOTVIS ).1 5.2 Differenceintotalvisualmagnificationbetweenleftandrighto

10、pticalsystems2 5.3 Differenceinaxesbetweenleftandrightopticalsystems2 5.4 Differenceinthecentresoftheimagefieldsbetweenleftandrightopticalsystems2 5.5 Differenceinimagingrotationsbetweenrightandleftimages2 5.6 Axialshiftofobjectplanebymagnificationchange2 5.7 Lateralshiftofimageplanebymagnificationc

11、hange.2 5.8 Focusdifferencebetweenleftandrightopticalsystems2 5.9 Resolutionforthehighestmagnificationatthecentreofthefield2 5.10 Differenceinexitpupilheightsbetweenleftandrightopticalsystems2 5.11 Minimumrangeforinterpupillarydistance.2 5.12 Calibrationerrorifadioptrescaleisused2 5.13 Minimumeyepie

12、cedioptreadjustmentrange.2 6 Testmethods3 6.1 Apparatus.3 6.2 Apparatusconfiguration.4 6.3 Testprocedures.4 Bibliography9ISO15227:2000(E) iv Foreword ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO memberbodies).TheworkofpreparingInternationalSt

13、andardsisnormallycarriedoutthroughISOtechnical committees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhas therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,in liaisonwithISO,alsotakepartinthework.ISOcollaboratesclosel

14、ywiththeInternationalElectrotechnical Commission(IEC)onallmattersofelectrotechnicalstandardization. InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3. DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting. Publicatio

15、nasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote. AttentionisdrawntothepossibilitythatsomeoftheelementsofthisInternationalStandardmaybethesubjectof patentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights. InternationalStandardISO15227wasprep

16、aredbyTechnicalCommitteeISO/TC172, Optics and optical instruments, Subcommittee SC 5, Microscopes and endoscopes.INTERNATIONALSTANDARD ISO15227:2000(E)1 OpticsandopticalinstrumentsMicroscopesTestingof stereomicroscopes 1 Scope ThisInternationalStandardspecifiestestconditionsandrecommendedtestmethods

17、toensuretheminimum requirementsforstereomicroscopes.TheseminimumrequirementsaregiveninISO10936-1,ISO11884-1and ISO11884-2. ThetestmethodsspecifiedinthisInternationalStandardarerecommended,butuseofothertestmethodsis permittedifthesameresultsareobtained. 2 Normativereferences Thefollowingnormativedocu

18、mentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsof thisInternationalStandard.Fordatedreferences,subsequentamendmentsto,orrevisionsof,anyofthese publicationsdonotapply.However,partiestoagreementsbasedonthisInternationalStandardareencouragedto investigatethepossibilityofappl

19、yingthemostrecenteditionsofthenormativedocumentsindicatedbelow.For undatedreferences,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOandIEC maintainregistersofcurrentlyvalidInternationalStandards. ISO10934-1, Optics and optical instruments Vocabulary for microscopy Part 1: Light

20、microscopy. ISO/CIE10526, CIE standard illuminants for colorimetry. 3 Termsanddefinitions ForthepurposesofthisInternationalStandard,thetermsanddefinitionsgiveninISO10934-1apply. 4 Accuracyoftesting Testingshallbeperformedwithanaccuracybetterthan10%ofthevaluetobedetermined.Measurementsshall becarried

21、outaccordingtogeneralrulesofstatisticalevaluation. NOTE TheaccuracyofmeasurementmethodsandresultsbasedonstatisticalevaluationisdescribedintheISO5725 series. 5 Testconditions 5.1 Totalvisualmagnification(M TOTVIS ) Thetotalvisualmagnificationshallbemeasuredatthehighestmagnification(M max )andthelowes

22、tmagnification (M min )onaverticalcentreline.ISO15227:2000(E) 2 5.2 Differenceintotalvisualmagnificationbetweenleftandrightopticalsystems ThedifferenceshallbemeasuredatmagnificationsM max andM min onaverticalcentreline. 5.3 Differenceinaxesbetweenleftandrightopticalsystems Themaximumdifferenceshallb

23、emeasuredatmagnificationsM max andM min ,eachataninterpupillarydistance (IPD)of65mm. 5.4 Differenceinthecentresoftheimagefieldsbetweenleftandrightopticalsystems ThedifferenceshallbemeasuredatmagnificationsM max andM min eachatanIPDof65mm. 5.5 Differenceinimagingrotationsbetweenrightandleftimages The

24、differenceshallbemeasuredatIPDsof55mmand75mm. 5.6 Axialshiftofobjectplanebymagnificationchange ThemaximumshiftshallbemeasuredduringthemagnificationchangeofthestereomicroscopebetweenM max and M min . 5.7 Lateralshiftofimageplanebymagnificationchange Themaximumshiftshallbemeasuredduringthemagnificatio

25、nchangeofthestereomicroscopebetweenM max and M min . 5.8 Focusdifferencebetweenleftandrightopticalsystems ThedifferenceshallbemeasuredatmagnificationsM max andM min at0Donthedioptrescale. 5.9 Resolutionforthehighestmagnificationatthecentreofthefield Checktheresolutionchartunderilluminationwiththesta

26、ndardilluminanttypeAaccordingtoISO/CIE10526having anumericalaperturelargerthanthatoftheobjectiveofthestereomicroscope. 5.10Differenceinexitpupilheightsbetweenleftandrightopticalsystems Thedistanceshallbemeasuredat0DonthedioptrescaleandanIPDof65mm. 5.11Minimumrangeforinterpupillarydistance Therangesh

27、allbemeasuredattheexitpupilsoftheeyepiecessetat0Donthedioptrescale. 5.12Calibrationerrorifadioptrescaleisused TheerrorshallbemeasuredatanIPDof65mm. 5.13Minimumeyepiecedioptreadjustmentrange TherangeshallbemeasuredatanIPDof65mm.ISO15227:2000(E)3 6 Testmethods 6.1 Apparatus 6.1.1 Doubletelescope(seeFi

28、gure1). Twotelescopesaremechanicallycombinedwiththedistanceandconvergentanglebetweenthemeither adjustableorfixedtothevaluespecifiedbythemanufacturer,whilebothopticalaxesremainontheplane. Graticuleswithcross-lines,micrometerscalesandgoniometerscalesarefittedintheintermediateplanesofthe telescopes. 6.

29、1.2 Dioptrictester,placedonthetopsurfaceoftheeyepiece. 6.1.3 Centringtelescope,placedinplaceoftheeyepieceofthetelescope,forcentringtheexitpupilofthe stereomicroscope. Key 1 Eyepieces 2 Intermediateimageplanes 3 Objectives(f OT ) 4 Eyepieces(f OC ) 5 Primaryimageplanes 6 Erectingprisms 7 Objectives 8

30、 Objectplane 9 Doubletelescopewithmagnificationbetween2 and4 10Stereomicroscopetobetested Figure1ApparatusconfigurationwithadoubletelescopeISO15227:2000(E) 4 6.1.4 Testobject,placedintheobjectplaneofthestereomicroscopetobetestedandusedinaseparateor combinedformofthefollowingtestobjects: a) cross-lin

31、es; b) circularline; c) goniometerscale; d) resolutionchart. 6.1.5 Graticules,placedeitherontheprimaryimageplanesofthestereomicroscopeorontheimageplanesof thedoubletelescope(6.1.1)andusedinaseparateorcombinedformofthefollowinggraticules: a) cross-lines; b) circularline; c) micrometerscale; d) goniom

32、eterscale. 6.2 Apparatusconfiguration Forthecaseswherethedoubletelescope(see6.1.1andFigure1)isused(6.3.1through6.3.3,and6.3.5),that isfixedtothestereomicroscopetoconformtothespecificationsofthestereomicroscope,and10 eyepieces arefocusedatthe0Dposition.Fortheothercases(6.3.4,and6.3.6through6.3.13),th

33、edioptreadjustmentis madeaccordingtotheinstructionsintheusermanual. 6.3 Testprocedures 6.3.1 Totalvisualmagnification(M TOTVIS ) a) Placeamicrometerscaleasthetestobjectatthecentreoftheobjectplane. b) Readtheimagesizey“ofadistanceyintheobjectplanewiththemicrometerscaleplacedintheintermediate planeofe

34、achtelescope. c) Calculatethetotalvisualmagnificationusingthefollowingequation: M y fy TOTVIS OT 250 (1) wheref OT isthefocallength,expressedinmillimetres,oftheobjectiveofthetelescope. 6.3.2 Differenceintotalvisualmagnificationbetweenleftandrightopticalsystems a) Placeamicrometerscaleasthetestobject

35、atthecentreoftheobjectplane. b) Readthesizey“ R andy“ L ofadistanceyintheobjectplanewiththemicrometerscaleplacedinthe intermediateplaneoftherightandlefttelescopesrespectively.ISO15227:2000(E)5 c) Calculatethedifference,expressedasapercentage,betweenrightandlefttotalvisualmagnificationsM TOTVISR andM

36、 TOTVISL usingthefollowingequation: M yy yy TOTVIS RL RL % 200 “ “ (2) where M TOTVIS isthedifferencebetweenM TOTVISR andM TOTVISL . 6.3.3 Differenceinaxesbetweenleftandrightopticalsystems 6.3.3.1 Verticalandhorizontaldifferencesinaxesbetweenleftandrightopticalsystems Thistestshouldbeappliedonlyifth

37、emechanicalaxesoftheeyepiecesareparalleltoeachotherduetodesign. a) Settheopticalaxesofthedoubletelescopeparalleltoeachother. b) Placethecross-linesasthetestobjectandfocusthem,usingthefocusingdriveofthestereomicroscope. c) Centrethecross-linesofthetestplatetothecross-linesintheprimaryimageplane. d) C

38、entretheleftrighttelescopetotheexitpupiloftheleftrightbeampathofthestereomicroscopeusingthe centringtelescope(6.1.3). e) Adjustthehorizontal(x-)andvertical(y-)directionsofthedoubletelescopesuntilthecross-linesintheleft righttelescopearecentredontheimageofthetestplate. f) Centretherightlefttelescopet

39、otheexitpupiloftherightleftbeampathofthestereomicroscopeusingthe centringtelescope. g) Adjustthedirectionoftherightlefttelescopeuntilthex-lineofthecross-linesinthetelescopegoesthrough thecentreoftheimageofthetestobject. h) Readthehorizontaldifference x“betweenthey-lineofthetelescopegraticuleandthece

40、ntreoftheimageof thetestplatewiththemicrometerscaleintherightlefttelescope. i) Calculatethehorizontaldifferenceinaxes x betweentheleftandrightopticalsystemsusingthefollowing equation. x arctan OT x f (3) where x“isthehorizontaldifferencemeasuredindivergentdirectionswiththetelescopegraticule(6.1.5).

41、j)Adjustthedirectionoftherightlefttelescopeuntilthey-lineofthecross-linesinthetelescopegoesthrough thecentreoftheimageofthetestobject. k)Readtheverticaldifference y“betweenthex-lineofthetelescopegraticuleandthecentreoftheimageof thetestobjectwiththemicrometerscaleintherightlefttelescope. l)Calculate

42、theverticaldifferenceinaxes y betweentheleftandrightopticalsystemsusingthefollowing equation. y arctan OT y f (4) where y“istheverticaldifferencemeasuredwiththetelescopegraticule.ISO15227:2000(E) 6 6.3.3.2 Verticaldifferenceoftheprimaryimagesbetweenrightandleftopticalsystems Thistestshouldbeappliedo

43、nlyifthemechanicalaxesoftheeyepiecesarenotparalleltoeachotherduetothe design. a) Placethecross-linesasthetestobjectandfocusthembytheuseofthefocusingdriveofthe stereomicroscope. b) Centrethecross-linesofthetestplatetothecross-linesintheprimaryimageplane. c) Centretheleftrighttelescopetotheexitpupilof

44、theleftrightbeampathofthestereomicroscopebyusing centringtelescope. d) Adjustthehorizontal(x-)andvertical(y-)directionsofthedoubletelescopesuntilthecross-linesintheleft righttelescopearecentredtotheimageofthetestplate. e) Centretherightlefttelescopetotheexitpupiloftherightleftbeampathofthestereomicr

45、oscopebyusing centringtelescope. f) Adjustthedirectionoftherightlefttelescopeuntilthey-lineofthecross-linesinthetelescopegoesthrough thecentreoftheimageofthetestobject,byvaryingtheconvergentangleofthedoubletelescope. g) Readtheverticaldifference y“betweenthex-lineofthetelescopegraticuleandthecentreo

46、ftheimageofthe testobjectwithmicrometerscaleintherightlefttelescope. h) Calculatetheverticaldifferenceinaxes y betweentheleftandrightopticalsystemsusingthefollowing equation. y arctan OT y f (5) where y“istheverticaldifferencemeasuredwiththetelescopegraticule. 6.3.4 Differenceinthecentresoftheimagef

47、ieldbetweenleftandrightopticalsystems a) Placethecross-lineswithmicrometerscalesasatestobject. b) Centrethecross-linestothecentreofthefielddiaphragmoftheeyepieceintheleftrightbeampathofthe stereomicroscope. c) Readthedifferenceinthecentresoftheimagefieldasthehorizontalandverticaldeviations xand yoft

48、he centreofthecross-linesfromthecentreofthefielddiaphragmoftheeyepieceintherightleftbeampathof thestereomicroscope. 6.3.5 Differenceinimagingrotationsbetweenrightandleftimages a) Alignthegoniometerscalesplacedattheintermediateplanesofthetelescopesinthehorizontaldirection. b) Placethecross-linesasthe

49、testobject. c) Alignthecross-linestothegoniometerscaleofthetelescopeintheleftrightbeampathofthe stereomicroscope. d) Readtheangleoftheimageofthecross-lineswiththegoniometerscaleofthetelescopeintherightleft beampathofthestereomicroscope.ISO15227:2000(E)7 6.3.6 Axialshiftofobjectplanebymagnificationchange a) Placethecross-linesasthetestobjectandfocusitatM max usingthefocusingdriveofthestereomicroscope. b) Changethemagnificationandfindthepositionofthefocusingdrivewher