BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf

上传人:livefirmly316 文档编号:585713 上传时间:2018-12-15 格式:PDF 页数:20 大小:1.80MB
下载 相关 举报
BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf_第1页
第1页 / 共20页
BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf_第2页
第2页 / 共20页
BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf_第3页
第3页 / 共20页
BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf_第4页
第4页 / 共20页
BS ISO 18562-4-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate《医疗保健应用中呼吸气体通道的生物相容性评估 冷凝物中析出物试验》.pdf_第5页
第5页 / 共20页
亲,该文档总共20页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS ISO 18562-4:2017Biocompatibility evaluation of breathing gas pathways in healthcare applicationsPart 4: Tests for leachables in condensateBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS ISO 18562-4:2017 BRITISH STANDARDNational forewordThis British Standard is

2、the UK implementation of ISO 18562-4:2017. The UK participation in its preparation was entrusted to TechnicalCommittee CH/121/9, Lung Ventilators informative material appearing outside of tables, such as notes, examples and references: in smaller type. Normative text of tables is also in a smaller t

3、ype; test specifications: italic type; terms defined in Clause 3 of this document or as noted: small capitals type.In this document, the conjunctive “or” is used as an “inclusive or” so a statement is true if any combination of the conditions is true.The verbal forms used in this document conform to

4、 usage described in Annex H of the ISO/IEC Directives, Part 2. For the purposes of this document, the auxiliary verb:a) “shall” means that compliance with a requirement or a test is mandatory for compliance with this document;b) “should” means that compliance with a requirement or a test is recommen

5、ded but is not mandatory for compliance with this document;c) “may” is used to describe a permissible way to achieve compliance with a requirement or test. ISO 2017 All rights reserved vBS ISO 18562-4:2017ISO 18562-4:2017(E)An asterisk (*) as the first character of a title or at the beginning of a p

6、aragraph or table title indicates that there is guidance or rationale related to that item in Annex A.The attention of Member Bodies is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised ISO publi

7、cation in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 3 years from the date of publ

8、ication for equipment newly designed and not earlier than 5 years from the date of publication for equipment already in production.vi ISO 2017 All rights reservedBS ISO 18562-4:2017INTERNATIONAL STANDARD ISO 18562-4:2017(E)Biocompatibility evaluation of breathing gas pathways in healthcare applicati

9、ons Part 4: Tests for leachables in condensate1 ScopeThis document specifies tests for substances leached by liquid water condensing into gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a pat

10、ient in all environments. The tests of this document are intended to quantify hazardous water-soluble substances that are leached from the medical device, its parts or accessories by condensate and then conveyed by that liquid to the patient. This document establishes acceptance criteria for these t

11、ests.This document addresses potential contamination of the gas stream arising from the gas pathways, which is then conducted to the patient.This document applies over the expected service life of the medical device in normal use and takes into account the effects of any intended processing or repro

12、cessingThis document does not address biological evaluation of the surfaces of gas pathways that are in direct contact with the patient. The requirements for direct contact surfaces are found in the ISO 10993 series.Medical devices, parts or accessories containing gas pathways that are addressed by

13、this document include, but are not limited to, ventilators, anaesthesia workstations (including gas mixers), breathing systems, oxygen conserving devices, oxygen concentrators, nebulizers, low-pressure hose assemblies, humidifiers, heat and moisture exchangers, respiratory gas monitors, respiration

14、monitors, masks, mouth pieces, resuscitators, breathing tubes, breathing systems filters, Y-pieces and any breathing accessories intended to be used with such devices. The enclosed chamber of an incubator, including the mattress, and the inner surface of an oxygen hood are considered to be gas pathw

15、ays and are also addressed by this document.This document does not address contamination already present in the gas supplied from the gas sources while medical devices are in normal use.EXAMPLE Contamination arriving at the medical device from gas sources such as medical gas pipeline systems (includ

16、ing the non-return valves in the pipeline outlets), outlets of pressure regulators connected or integral to a medical gas cylinder, or room air taken into the medical device is not addressed by ISO 18562 series.This document does not address contact with drugs or anaesthetic agents. If a medical dev

17、ice is intended to be used with anaesthetic agents or drugs, then additional testing can be required.This document is intended to be read in conjunction with ISO 18562-1.NOTE This document has been prepared to address the relevant essential principles of safety and performance as indicated in Annex

18、B.2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin

19、g any amendments) applies. ISO 2017 All rights reserved 1BS ISO 18562-4:2017ISO 18562-4:2017(E)ISO 7396-1:2016, Medical gas pipeline systems Part 1: Pipeline systems for compressed medical gases and vacuumISO 10993-1, Biological evaluation of medical devices Part 1: Evaluation and testing within a r

20、isk management processISO 10993-5, Biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicityISO 10993-10, Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitizationISO 10993-12:2012, Biological evaluation of medical devices Part 12: Sample pr

21、eparation and reference materialsISO 14971:2007, Medical devices Application of risk management to medical devicesISO 18562-1:2017, Biocompatibility evaluation of breathing gas pathways in healthcare applications Part 1: Evaluation and testing within a risk management process3 Terms and definitionsF

22、or the purposes of this document, the terms and definitions given in ISO 7396-1, ISO 14971 and ISO 18562-1 apply.ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing

23、platform: available at h t t p :/ www .iso .org/ obpNOTE For convenience, an alphabetized index of all defined terms and their sources used in this document are given in Annex C.4 General principles4.1 Type testsThe tests described in this document are type tests. Type tests are performed on the fin

24、al medical device, a component of the medical device or a representative sample of the medical device, part or accessory being evaluated. If representative samples are used, (i.e. manufactured and processed by equivalent methods), consideration should be made regarding whether or not the differences

25、 between the representative sample and the final medical device or component could affect the results of the test. Testing of representative samples (manufactured and processed by equivalent methods) instead of the final medical device should be supported by a description of any differences between

26、the representative sample and the final medical device, and a detailed rationale for why each difference is not expected to impact the biocompatibility of the final medical device.NOTE Some authorities having jurisdiction evaluate these differences and rationales.4.2 GeneralAll gas pathways from whi

27、ch the patient inspires gas shall be evaluated using the strategy detailed in ISO 18562-1.2 ISO 2017 All rights reservedBS ISO 18562-4:2017ISO 18562-4:2017(E)5 Leachable substances in condensate5.1 GeneralA medical device, part or accessory shall not add to the condensate leachable substances at lev

28、els that create an unacceptable risk to the patient. All gas pathways from which the patient inspires gas in normal condition, where gas in the gas pathway can reach 100 % saturation with water at some point in the gas pathway, condensate can form on the gas pathway surfaces, and liquid condensate c

29、an reach the patient,shall be evaluated for condensate emissions. The evaluation should use the risk management process to assess if testing is required.NOTE 1 Condensate can form in gas pathways and can take the form of liquid drops or a film of water on the gas pathway walls. This liquid water can

30、 extract substances from the materials of the walls that would not be extracted by the breathing gas alone. If this liquid condensate can reach the patient, it could potentially convey harmful substances to the patient.NOTE 2 The evaluation of some components, which are identical in formulation, pro

31、cessing and preparation for use to an existing component of a medical device that has been previously tested, might conclude that no further testing is required. Refer to ISO 18562-1:2017, Figure 2.Sections of the gas pathway from which the patient cannot be exposed to condensate need not be tested.

32、If the risk management process determines that testing is required, the tests of 5.2 shall be performed.If the medical device under evaluation has already been evaluated as an external communicating medical device with contact to tissue/bone/dentin according to ISO 10993-1, then the following tests

33、need not be performed.EXAMPLE A tracheal tube, because of its direct contact with the patient, is evaluated according to ISO 10993-1. In this case, the tests of this document are not required.NOTE 3 Some authorities having jurisdiction might require these tests if the medical device is intended for

34、use on particularly vulnerable patient populations, such as neonates.5.2 * Test methodTest for leachable substances in condensate is as follows.a) To collect a sample, either1) produce and collect condensate under clinically relevant conditions, or2) circulate the water over the surface of the sampl

35、e at a temperature representative of clinical use, or3) * perform an aqueous extraction on the internal gas contact surfaces according to the method of ISO 10993-12:2012, Clause 10, with the extract at clinically relevant temperatures, for a clinically relevant duration of time.EXAMPLE There is no c

36、linical relevance to performing a 24-h extraction on a medical device that is only intended to be used on a patient for 20 min. However, the underlying principle remains “what is the dose to the patient in 24 h”. If a medical device could be used multiple times in a 24-h period, then the maximum lik

37、ely cumulative time is considered. Additionally, if the medical device is consumable and replaced consecutively, the 24-h exposure can be higher due to additive effects.NOTE 1 See the rationale in Annex A for further considerations if performing an aqueous extraction. ISO 2017 All rights reserved 3B

38、S ISO 18562-4:2017ISO 18562-4:2017(E)This document is not intended to be prescriptive in the selection of medical device configuration, test method and conditions used to produce the sample. Choices should be justified and documented.b) * Determine the content of metal ions in the condensate or extr

39、act using the method of pharmacopeias (e.g. USP17) or another relevant method. Evaluate the results based on limits defined in USP18or other validated sources. If not all the metals listed in USP are screened for, then justify and document the rationale.NOTE 2 Similar analytical methods are useful t

40、o assess other metals of concern, such as nickel and chromium.If exposure limits are not available for specific metals identified in condensate, then derive a tolerable intake using the method of ISO 18562-1:2017, Clause 7.Convert the concentration of each metal ion to a total dose/day by considerin

41、g the total amount of liquid condensate that reaches the patient in a day as 1 ml.c) * If required in order to achieve detection of concentrations at the limits specified, enrich the organic impurities in the condensate or extract using established methods, such as stir bar sorptive extraction, soli

42、d phase microextraction, liquid-liquid extraction or a demonstrably equivalent method. Then identify and quantify organic impurities using GC-MS (gas chromatography-mass spectrometry) or an equivalent method.Convert the concentration of each substance to a total dose per patient per day by consideri

43、ng the total amount of condensate that reaches the patient per day as 1 ml.Confirm that the dose of each identified substance delivered to the patient in 1 ml of condensate or extract is less than the tolerable intake or threshold of toxicological concern derived from the method of ISO 18562-1:2017,

44、 Clause 7.The route of exposure is into the lung and therefore considered inhalational, not oral ingestion.d) * Perform a cytotoxicity test according to ISO 10993-5 on the condensate or extract. There are several different methods offered in ISO 10993-5. Select a method suitable for liquids.NOTE 3 T

45、he MEM elution method is a sensitive method, and is normally accepted by authorities having jurisdiction as an appropriate method.e) * Perform a sensitization test according to ISO 10993-10 on the condensate or extract. Select a method suitable for liquids.NOTE 4 The LLNA method is normally accepted

46、 by authorities having jurisdiction as an appropriate method. However, there are concerns that this particular test method might not be wholly suitable if the medical device includes nickel, the extract contains a mixture of substances, rather than a single leached substance, the aqueous extract doe

47、s not include a vehicle to ensure the extract is in contact with the skin, or novel materials that do not penetrate the skin are present (e.g. nanomaterials).4 ISO 2017 All rights reservedBS ISO 18562-4:2017ISO 18562-4:2017(E)Annex A (informative) Rationale and guidanceA.1 General guidanceThis annex

48、 provides rationale for the important requirements of this document and is intended for those who are familiar with the subject of this document, but who have not participated in its development. An understanding of the reasons for the main requirements is considered to be essential for its proper a

49、pplication. Furthermore, as clinical practice and technology change, it is believed that rationale for the present requirements will facilitate any revision of this document necessitated by those developments.The clauses and subclauses in this annex have been so numbered to correspond to the clauses and subclauses in this document to which they refer. The numbering is, therefore, not consecutive.A.2 Rationale for particular clauses and subclauses5.2 Test methoda) 3)Typically, the extraction ratio will be 3 cm2of inner gas pathway

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1