1、Government Gouvernement of Canada du Canada Canadian General Office des normes Standards Board gnrales du Canada CAN/CGSB-3.5-2016CORRIGENDUM No. 1RECTIFICATIF N 1 ICS 75.160.20Experience and excellenceExprience et excellenceCORRIGENDUM RECTIFICATIF June 2016 Juin 2016 Automotive gasoline Voting mem
2、bership list Under Producer category for member Porter, S., replace Biofuels Consulting by Renewable Industries Canada. Table 3D Replace Table 3D in the standard with the following revised version. Please note thatthe reference to footnote “d” in SCSZ Vapour pressure column for the period ofJune 1 t
3、o August 31 has been deleted. Essence automobile Liste des membres votants Dans la Catgorie producteur, pour le membre Porter, S., remplacer Biofuels Consulting par Industries renouvelables Canada. Tableau 3D Remplacer le tableau 3D dans la norme par la version rvise qui suit. Prire de noter que la
4、rfrence la note en bas de page d de la colonne Tension de vapeur SZCVM a t supprime pour la priode du 1erjuin au 31 aot. HER MAJESTY THE QUEEN IN RIGHT OFCANADA, as represented by the Minister of PublicServices and Procurement, the Minister responsible forthe Canadian General Standards Board, (2016)
5、. No part of this publication may be reproduced in any formwithout the prior permission of the publisher. SA MAJEST LA REINE DU CHEF DU CANADA, reprsente par la ministre des Services publics et delApprovisionnement, la ministre responsable de lOffice des normes gnrales du Canada (2016). Aucune parti
6、e de cette publication ne peut tre reproduite daucune manire sans la permission pralable de lditeur. 2 CAN/CGSB-3.5-2016 Corrigendum No. 1/Rectificatif No 1 Table 3D Volatility requirements for Zone D (Southern Ontario and Southern Quebec) Zone volatility limits Southern Ontario and Southern Quebec
7、The portions of Ontario and Quebec south of latitude 46 North, including the Seaway Corridor Sub Zone (SCSZ)aMonth Dates Vapour pressure SCSZ Vapour pressureT10 Evaporation T50 Evaporation T90 Evaporation Driveability index Min. (kPa) Max. (kPa) Max. kPa)bMin.(C) Max.(C) Min. (C) Max. (C) Max. (C) M
8、ax.c(C) January 1 15 65 110 - 50 60 110 185 550 January 16 31 65 110 - 50 60 110 185 550 February 1 15 65 110 - 50 60 110 185 550 February 16 28 (29) 50 110 - 55 60 110 185 560 March 1 15 50 110 - 55 60 110 185 560 March 16 - 31 45 110 - 60 60 120 190 575 April 1 - 15 45 97 - 60 60 120 190 575 April
9、 16 - 30 35 97 - 70 60 120 190 590 May 1 - 15 35 86 - 70 62 120 190 590 May 16 - 31 35 72 62d35 70 66 120 190 590 June 1 - 15 35 72 62 35 70 66 120 190 590 June 16 - 30 35 72 62 35 70 66 120 190 590 July 1 - 15 35 72 62 35 70 66 120 190 590 July 16 - 31 35 72 62 35 70 66 120 190 590 August 1 - 15 35
10、 72 62 35 70 66 120 190 590 August 16 - 31 35 72 62 35 70 66 120 190 590 September 1 - 15 35 72 62d35 70 66 120 190 590 September 16 - 30 35 97 - 70 60 120 190 590 October 1 - 15 45 97 - 70 60 120 190 575 October 16 - 31 45 110 - 60 60 120 190 575 November 1 - 15 45 110 - 60 60 120 190 575 November
11、16 - 30 45 110 - 60 60 120 190 575 December 1 15 50 110 - 55 60 110 185 560 December 16 31 50 110 - 55 60 110 185 560 aThe Seaway Corridor Sub-Zone (SCSZ) is defined in two parts. 1) That part of Ontario that lies south of a straight line passing through Arnprior and Grand Bend. Where the line so de
12、scribed runs across a local municipality, the entire local municipality is part of the sub-zone. This is defined by the Ontario Regulation (see Annex B, B2.7.1). 2) That part of Southwestern Quebec defined in the Qubec Petroleum Products Act (see Annex B, B2.9.1) as “The Outaouais-Montral Corridor“.
13、 bSee 5.3.1. cIf the required maximum vapour pressure is less than 72 kPa then the maximum DI shall be 597. dThis limit only applies to the Ontario portion of the SCSZ from May 15 to September 14; the point of application is defined in the Ontario Volatility Regulation (Annex B, B2.7.1). CAN/CGSB-3.
14、5-2016 3 Corrigendum No. 1/Modificatif No 1 Tableau 3D Exigences relatives la volatilit dans la zone D (Sud de lOntario et Sud du Qubec) Limites de volatilit Sud de lOntario et Sud du Qubec Les parties de lOntario et du Qubec au sud de 46 de latitude nord, y compris la sous-zone du couloir de la Voi
15、e maritime (SZCVM)aMois Dates Tension de vapeur Tensionde vapeur SZCVM T10 vaporation T50 vaporation T90 vaporation Indice defficacit de carburation Min. (kPa) Max. (kPa) Max. (kPa)bMin.(C)Max.(C) Min. (C) Max. (C) Max. (C) Max.c(C) Janvier 1erau 15 65 110 - 50 60 110 185 550 Janvier 16 au 31 65 110
16、 - 50 60 110 185 550 Fvrier 1erau 15 65 110 - 50 60 110 185 550 Fvrier 16 au 28 (29) 50 110 - 55 60 110 185 560 Mars 1erau 15 50 110 - 55 60 110 185 560 Mars 16 au 31 45 110 - 60 60 120 190 575 Avril 1erau 15 45 97 - 60 60 120 190 575 Avril 16 au 30 35 97 - 70 60 120 190 590 Mai 1er au 15 35 86 - 70
17、 62 120 190 590 Mai 16 au 31 35 72 62d 35 70 66 120 190 590 Juin 1er au 15 35 72 62 35 70 66 120 190 590 Juin 16 au 30 35 72 62 35 70 66 120 190 590 Juillet 1er au 15 35 72 62 35 70 66 120 190 590 Juillet 16 au 31 35 72 62 35 70 66 120 190 590 Aot 1er au 15 35 72 62 35 70 66 120 190 590 Aot 16 au 31
18、 35 72 62 35 70 66 120 190 590 Septembre 1er au 15 35 72 62d35 70 66 120 190 590 Septembre 16 au 30 35 97 - 70 60 120 190 590 Octobre 1er au 15 45 97 - 70 60 120 190 575 Octobre 16 au 31 45 110 - 60 60 120 190 575 Novembre 1er au 15 45 110 - 60 60 120 190 575 Novembre 16 au 30 45 110 - 60 60 120 190
19、 575 Dcembre 1erau 15 50 110 - 55 60 110 185 560 Dcembre 16 au 31 50 110 - 55 60 110 185 560 aLa sous-zone du corridor de la voie maritime (SZCVM) se divise en deux parties. 1) La partie de lOntario qui stend au sud dune ligne droite traversant Arnprior et Grand Bend. Lorsque cette ligne traverse un
20、e localit, toute la localit fait partie de la sous-zone. Cette partie est dfinie par le rglement de lOntario (voir lannexe B, B2.7.1). 2) La partie du Sud-Ouest du Qubec dfinie dans la Loi sur les produits ptroliers du Qubec (voir lannexe B, B2.9.1) comme tant le corridor Outaouais-Montral . bVoir 5
21、.3.1. cSi la tension de vapeur maximale exige est infrieure 72 kPa, lindice defficacit de carburation maximal doit tre de 597. dCette limite ne sapplique qu la partie ontarienne de la SZCVM du 15 mai au14 septembre; le point dapplication est dfini dans le rglement Gasoline Volatility de lOntario (vo
22、ir lannexe B, B2.7.1). 4 CAN/CGSB-3.5-2016 Corrigendum No. 1/Rectificatif No 1 Annex C Annexe C List of municipalities in the Outaouais-Montral corridor Liste des municipalits du corridor Outaouais-Montral This change only applies to the French version of the standard. Remplacer *16 HORS MRC LAURENTIDES par *15 HORS MRC LAURENTIDES.