1、Government Gouvernement of Canada du Canada Canadian General Office des normes Standards Board gnrales du Canada CAN/CGSB-3.511-2016AMENDMENT No. 1MODIFICATIF N 1 ICS 75.160.20Experience and excellenceExprience et excellenceAMENDMENT MODIFICATIF January 2017 Janvier 2017 Oxygenated automotive gasoli
2、ne containing ethanol (E1-E10) Essence automobile oxygne contenant de lthanol (E1-E10) HER MAJESTY THE QUEEN IN RIGHT OFCANADA, as represented by the Minister of PublicWorks and Government Services, the Minister responsible for the Canadian General StandardsBoard, (2017). No part of this publication
3、 may bereproduced in any form without the prior permission ofthe publisher. SA MAJEST LA REINE DU CHEF DU CANADA, reprsente par le ministre des Travaux publics et Services gouvernementaux, le ministre responsable de lOffice des normes gnrales du Canada (2017). Aucune partie de cette publication ne p
4、eut tre reproduite daucune manire sans la permission pralable de lditeur. 2 CAN/CGSB-3.511-2016 Amendment No. 1/Modificatif No 1 Voting membership list Liste des membres votants Under General interest category for member Hanganu, A., replace OTI Canada Group by Inspectorate - A Bureau Veritas Group
5、Company Dans la Catgorie dintrt gnral, pour le membre Hanganu, A., remplacer OTI Canada Group par Inspectorate - A Bureau Veritas Group Company. Table 3C Tableau 3C Replace Table 3C in the standard with the revised version on page 3 of this amendment. Remplacer le tableau 3C dans la norme par la ver
6、sion rvise de la page 6 du prsent modificatif. Table 3D Replace table 3D in the standard with the revised version on page 4 of this amendment. Tableau 3D Remplacer le tableau 3D dans la norme par la version rvise de la page 7 du prsent modificatif. Table 3E Replace Table 3E in the standard with the
7、revised version on page 5 of this amendment.Tableau 3E Remplacer le tableau 3E dans la norme par la version rvise de la page 8 du prsent modificatif. CAN/CGSB-3.511-2016 3 Amendment No. 1/Modificatif No 1 Replace tables 3C, 3D and 3E in the standard with the following updated versions. Table 3C Vola
8、tility requirements for Zone C (Northern Ontario and Central Quebec) Zone volatility limits Northern Ontario and Central Quebec The portions of Ontario lying north of latitude 46 North, south of latitude 53 North and east of 90 West longitude and Quebec lying north of latitude 46 North and south of
9、latitude 51 North. Month Dates Vapour pressure T10 Evaporation T50 Evaporation T90 Evaporation Driveabilityindex Min. (kPa) Max. (kPa) Min. (C) Max. (C) Min. (C) Max. (C) Max. (C) Max. (C) January 1 15 85 110 - 50 60 110 185 540 January 16 31 85 110 - 50 60 110 185 540 February 1 15 85 110 - 50 60 1
10、10 185 540 February 16 28 (29) 65 110 - 50 60 110 185 550 March 1 15 65 110 - 50 60 110 185 550 March 16 31 50 110 - 55 60 110 185 560 April 1 15 50 110 - 55 60 110 185 560 April 16 30 45 97 - 60 60 120 190 575 May 1 15 45 97 - 70 60 120 190 590 May 16 31 35 86 - 70 62 120 190 590 June 1 15 35 72 35
11、 70 66 120 190 590 June 16 30 35 72 35 70 66 120 190 590 July 1 15 35 72 35 70 66 120 190 590 July 16 31 35 72 35 70 66 120 190 590 August 1 15 35 72 35 70 66 120 190 590 August 16 31 35 72 35 70 66 120 190 590 September 1 15 35 97a- 70 60 120 190 590 September 16 30 35 110 - 70 60 120 190 590 Octob
12、er 1 15 45 110 - 60 60 120 190 575 October 16 31 45 110 - 60 60 120 190 575 November 1 15 45 110 - 60 60 110 190 575 November 16 30 50 110 - 55 60 110 185 560 December 1 15 65 110 - 50 60 110 185 550 December 16 31 65 110 - 50 60 110 185 550 aIn Ontario the maximum allowable vapour pressure is 72 kP
13、a from September 1 to September 14 as per the Ontario Volatility Regulation (see Annex B, B2.7.1) 4 CAN/CGSB-3.511-2016 Amendment No. 1/Modificatif No 1 Table 3D Volatility requirements for Zone D (Southern Ontario and Southern Quebec) Zone volatility limits Southern Ontario and Southern Quebec The
14、portions of Ontario and Quebec south of latitude 46 North, including the Seaway Corridor Sub Zone (SCSZ)aMonth Dates Vapour pressure SCSZ Vapour pressureT10 Evaporation T50 Evaporation T90 Evaporation Driveability index Min. (kPa) Max. (kPa) Max. kPa)bMin.(C) Max.(C) Min. (C) Max. (C) Max. (C) Max.c
15、(C) January 1 15 65 110 - 50 60 110 185 550 January 16 31 65 110 - 50 60 110 185 550 February 1 15 65 110 - 50 60 110 185 550 February 16 28 (29) 50 110 - 55 60 110 185 560 March 1 15 50 110 - 55 60 110 185 560 March 16 - 31 45 110 - 60 60 120 190 575 April 1 - 15 45 97 - 60 60 120 190 575 April 16
16、- 30 35 97 - 70 60 120 190 590 May 1 - 15 35 86 - 70 62 120 190 590 May 16 - 31 35 72d35 70 66 120 190 590 June 1 - 15 35 72 62 35 70 66 120 190 590 June 16 - 30 35 72 62 35 70 66 120 190 590 July 1 - 15 35 72 62 35 70 66 120 190 590 July 16 - 31 35 72 62 35 70 66 120 190 590 August 1 - 15 35 72 62
17、35 70 66 120 190 590 August 16 - 31 35 72 62 35 70 66 120 190 590 September 1 - 15 35 72d35 70 66 120 190 590 September 16 - 30 35 97 - 70 60 120 190 590 October 1 - 15 45 97 - 70 60 120 190 575 October 16 - 31 45 110 - 60 60 120 190 575 November 1 - 15 45 110 - 60 60 120 190 575 November 16 - 30 45
18、 110 - 60 60 120 190 575 December 1 15 50 110 - 55 60 110 185 560 December 16 31 50 110 - 55 60 110 185 560 aThe Seaway Corridor Sub-Zone (SCSZ) is defined in two parts. 1) That part of Ontario that lies south of a straight line passing through Arnprior and Grand Bend. Where the line so described ru
19、ns across a local municipality, the entire local municipality is part of the sub-zone. This is defined by the Ontario Regulation (see Annex B, B2.7.1). 2) That part of Southwestern Quebec defined in the Qubec Petroleum Products Act (see Annex B, B2.9.1) as “The Outaouais-Montral Corridor“. bSee 5.3.
20、1. cIf the required maximum vapour pressure is less than 72 kPa then the maximum DI shall be 597. dIn the case of the Ontario portion of the SCSZ, the 62 kPa limit also applies from May 15 to May 31 and from September 1 to September 14; the point of application is defined in the Ontario Volatility R
21、egulation (Annex B, B2.7.1). CAN/CGSB-3.511-2016 5 Amendment No. 1/Modificatif No 1 Table 3E Volatility requirements for Zone E (Atlantic) Zone volatility limits Atlantic Canada The island of Newfoundland, the provinces of New Brunswick, Nova Scotia and Prince Edward Island and Les Iles de la Madele
22、ine. Month Dates Vapour pressureT10 EvaporationT50 Evaporation T90 EvaporationMax. (C) Driveability index Max. (C) Min. (kPa) Max. (kPa) NewfoundlandMin.(C)Newfound-land Max. (C) Class 1aClass 2bMin.(C) Max.(C) Class 1aClass 2bMax. (kPa) Max.(kPa) Min. (C) Min. (C) January 1 15 65 110 107 - 50 60 11
23、0 185 550 January 16 31 65 110 107 - 50 60 110 185 550 February 1 15 65 110 107 - 50 60 110 185 550 February 16 28 (29) 50 110 107 - 55 60 110 185 560 March 1 15 50 110 107 - 55 60 110 185 560 March 16 31 45 110 107 - 60 60 120 190 575 April 1 - 15 45 110 107 - 60 60 120 190 575 April 16 - 30 35 97
24、107 - 70 60 120 190 590 May 1 - 15 35 97c97 - 70 60 120 190 590 May 16 - 31 35 7297 72 35 70 66 60 66 120 190 590 June 1 - 15 35 72 86 72 35 70 66 62 66 120 190 590 June 16 - 30 35 72 86 72 35 70 66 62 66 120 190 590 July 1 - 15 35 72 86 72 35 70 66 62 66 120 190 590 July 16 - 31 35 72 86 72 35 70 6
25、6 62 66 120 190 590 August 1 - 15 35 72 86 72 35 70 66 62 66 120 190 590 August 16 - 31 35 72 86 72 35 70 66 62 66 120 190 590 September 1 - 15 35 72 97 72 35 70 66 60 66 120 190 590 September 16 - 30 35 97 97 - 70 60 120 190 590 October 1 - 15 35 110 107 - 70 60 120 190 590 October 16 - 31 45 110 1
26、07 - 60 60 120 190 575 November 1 15 45 110 107 - 60 60 120 190 575 November 16 30 45 110 107 - 60 60 120 190 575 December 1 15 50 110 107 - 55 60 110 185 560 December 16 31 50 110 107 - 55 60 110 185 560 aNewfoundland Class 1 is that part of the Island on Newfoundland lying north of latitude 49 (se
27、e Annex B, B2.5). bNewfoundland Class 2 is that part of the Island on Newfoundland lying south of latitude 49 (see Annex B, B2.5). cIn Nova Scotia and New Brunswick the 72 kPa maximum is required at Terminals starting May 15 (see Annex B, B2.4 and B2.6). 6 CAN/CGSB-3.511-2016 Amendment No. 1/Modific
28、atif No 1 Remplacer les tableaux 3C, 3D et 3E de la norme par les tableaux rviss suivants. Tableau 3C Exigences relatives la volatilit dans la zone C (Nord de lOntario et Centre du Qubec) Limites de volatilit Nord de lOntario et Centre du Qubec Les parties de lOntario au nord de 46 de latitude nord,
29、 au sud de 53 de latitude nord et lest de 90 de longitude ouest, et du Qubec, au nord de 46 de latitude nord et au sud de 51 de latitude nord. Mois Dates Tension de vapeur T10 vaporation T50 vaporation T90 vaporation Indice defficacit de carburation Min. (kPa) Max. (kPa) Min. (C) Max.(C) Min. (C) Ma
30、x. (C) Max. (C) Max. (C) Janvier 1erau 15 85 110 - 50 60 110 185 540 Janvier 16 au 31 85 110 - 50 60 110 185 540 Fvrier 1erau 15 85 110 - 50 60 110 185 540 Fvrier 16 au 28 (29) 65 110 - 50 60 110 185 550 Mars 1erau 15 65 110 - 50 60 110 185 550 Mars 16 au 31 50 110 - 55 60 110 185 560 Avril 1erau 15
31、 50 110 - 55 60 110 185 560 Avril 16 au 30 45 97 - 60 60 120 190 575 Mai 1erau 15 45 97 - 70 60 120 190 590 Mai 16 au 31 35 86 - 70 62 120 190 590 Juin 1erau 15 35 72 35 70 66 120 190 590 Juin 16 au 30 35 72 35 70 66 120 190 590 Juillet 1erau 15 35 72 35 70 66 120 190 590 Juillet 16 au 31 35 72 35 7
32、0 66 120 190 590 Aot 1erau 15 35 72 35 70 66 120 190 590 Aot 16 au 31 35 72 35 70 66 120 190 590 Septembre 1erau 15 35 97a- 70 60 120 190 590 Septembre 16 au 30 35 110 - 70 60 120 190 590 Octobre 1erau 15 45 110 - 60 60 120 190 575 Octobre 16 au 31 45 110 - 60 60 120 190 575 Novembre 1erau 15 45 110
33、 - 60 60 110 190 575 Novembre 16 au 30 50 110 - 55 60 110 185 560 Dcembre 1er au 15 65 110 - 50 60 110 185 550 Dcembre 16 au 31 65 110 - 50 60 110 185 550 aEn Ontario, la tension de vapeur permise est de 72 kPa du 1erau 14 septembre tel quil est dfini dans le rglement Gasoline Volatility de lOntario
34、 (voir lannexe B, B2.7.1). CAN/CGSB-3.511-2016 7 Amendment No. 1/Modificatif No 1 Tableau 3D Exigences relatives la volatilit dans la zone D (Sud de lOntario et Sud du Qubec) Limites de volatilit Sud de lOntario et Sud du Qubec Les parties de lOntario et du Qubec au sud de 46 de latitude nord, y com
35、pris la sous-zone du couloir de la Voie maritime (SZCVM)aMois Dates Tension de vapeur Tension de vapeur SZCVM T10 vaporation T50 vaporation T90 vaporation Indice defficacit de carburation Min. (kPa) Max. (kPa) Max. (kPa)bMin.(C)Max.(C) Min. (C) Max. (C) Max. (C) Max.c(C) Janvier 1erau 15 65 110 - 50
36、 60 110 185 550 Janvier 16 au 31 65 110 - 50 60 110 185 550 Fvrier 1erau 15 65 110 - 50 60 110 185 550 Fvrier 16 au 28 (29) 50 110 - 55 60 110 185 560 Mars 1erau 15 50 110 - 55 60 110 185 560 Mars 16 au 31 45 110 - 60 60 120 190 575 Avril 1erau 15 45 97 - 60 60 120 190 575 Avril 16 au 30 35 97 - 70
37、60 120 190 590 Mai 1er au 15 35 86 - 70 62 120 190 590 Mai 16 au 31 35 72d 35 70 66 120 190 590 Juin 1er au 15 35 72 62 35 70 66 120 190 590 Juin 16 au 30 35 72 62 35 70 66 120 190 590 Juillet 1er au 15 35 72 62 35 70 66 120 190 590 Juillet 16 au 31 35 72 62 35 70 66 120 190 590 Aot 1er au 15 35 72
38、62 35 70 66 120 190 590 Aot 16 au 31 35 72 62 35 70 66 120 190 590 Septembre 1er au 15 35 72d35 70 66 120 190 590 Septembre 16 au 30 35 97 - 70 60 120 190 590 Octobre 1er au 15 45 97 - 70 60 120 190 575 Octobre 16 au 31 45 110 - 60 60 120 190 575 Novembre 1er au 15 45 110 - 60 60 120 190 575 Novembr
39、e 16 au 30 45 110 - 60 60 120 190 575 Dcembre 1erau 15 50 110 - 55 60 110 185 560 Dcembre 16 au 31 50 110 - 55 60 110 185 560 aLa sous-zone du corridor de la voie maritime (SZCVM) se divise en deux parties. 1) La partie de lOntario qui stend au sud dune ligne droite traversant Arnprior et Grand Bend
40、. Lorsque cette ligne traverse une localit, toute la localit fait partie de la sous-zone. Cette partie est dfinie par le rglement de lOntario (voir lannexe B, B2.7.1). 2) La partie du Sud-Ouest du Qubec dfinie dans la Loi sur les produits ptroliers du Qubec (voir lannexe B, B2.9.1) comme tant le cor
41、ridor Outaouais-Montral . bVoir 5.3.1. cSi la tension de vapeur maximale exige est infrieure 72 kPa, lindice defficacit de carburation maximal doit tre de 597. dDans le cas de la partie ontarienne de la SZCVM, la limite de 62 kPa sapplique galement du 15 mai au 31 mai et du 1erseptembre au 14 septem
42、bre; le point dapplication est dfini dans le rglement Gasoline Volatility de lOntario (voir lannexe B, B2.7.1). 8 CAN/CGSB-3.511-2016 Amendment No. 1/Modificatif No 1 Tableau 3E Exigences relatives la volatilit dans la zone E (Atlantique) Limites de volatilit Canada atlantique Lle de Terre-Neuve, le
43、s provinces du Nouveau-Brunswick, de la Nouvelle-cosse et de lle-du-Prince-douard ainsi que les les de la Madeleine.Mois Dates Tensionde vapeurT10 vaporationvaporation T50 T90 vaporationIndice defficacit de carburationMin. (kPa) Max. (kPa) Terre-Neuve-et-LabradorMin.(C)Terre-Neuve-et-Labrador Max. (
44、C) Max. (C) Max. (C) Cat. 1aCat. 2bMin.(C)Max.(C) Cat. 1aCat. 2b Max. (kPa)Max.(kPa)Min. (C) Min.(C) Janvier 1erau 15 65 110 107 - 50 60 110 185 550 Janvier 16 au 31 65 110 107 - 50 60 110 185 550 Fvrier 1erau 15 65 110 107 - 50 60 110 185 550 Fvrier 16 au 28 (29) 50 110 107 - 55 60 110 185 560 Mars
45、 1erau 15 50 110 107 - 55 60 110 185 560 Mars 16 au 31 45 110 107 - 60 60 120 190 575 Avril 1er au 15 45 110 107 - 60 60 120 190 575 Avril 16 au 30 35 97 107 - 70 60 120 190 590 Mai 1er au 15 35 97c 97 - 70 60 120 190 590 Mai 16 au 31 35 7297 72 35 70 66 60 66 120 190 590 Juin 1er au 15 35 72 86 72
46、35 70 66 62 66 120 190 590 Juin 16 au 30 35 72 86 72 35 70 66 62 66 120 190 590 Juillet 1er au 15 35 72 86 72 35 70 66 62 66 120 190 590 Juillet 16 au 31 35 72 86 72 35 70 66 62 66 120 190 590 Aot 1er au 15 35 72 86 72 35 70 66 62 66 120 190 590 Aot 16 au 31 35 72 86 72 35 70 66 62 66 120 190 590 Se
47、ptembre 1er au 15 35 72 97 72 35 70 66 60 66 120 190 590 Septembre 16 au 30 35 97 97 - 70 60 120 190 590 Octobre 1er au 15 35 110 107 - 70 60 120 190 590 Octobre 16 au 31 45 110 107 - 60 60 120 190 575 Novembre 1erau 15 45 110 107 - 60 60 120 190 575 Novembre 16 au 30 45 110 107 - 60 60 120 190 575
48、Dcembre 1erau 15 50 110 107 - 55 60 110 185 560 Dcembre 16 au 31 50 110 107 - 55 60 110 185 560 aLa catgorie 1 de Terre-Neuve sapplique la partie de lle de Terre-Neuve au nord de 49 de latitude (voir lannexe B, B2.5). bLa catgorie 2 de Terre-Neuve sapplique la partie de lle de Terre-Neuve au sud de 49 de latitude (voir lannexe B, B2.5). cEn Nouvelle-cosse et au Nouveau-Brunswick, le maximum de 72 kPa est exig aux terminaux partir du 15 mai (voir lannexe B, B2.4 et B2.6).