CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf

上传人:bowdiet140 文档编号:590386 上传时间:2018-12-15 格式:PDF 页数:13 大小:3.26MB
下载 相关 举报
CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf_第1页
第1页 / 共13页
CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf_第2页
第2页 / 共13页
CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf_第3页
第3页 / 共13页
CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf_第4页
第4页 / 共13页
CAN CSA-ISO IEC 14165-122A-2009 Information technology - Fibre channel - Part 122 Arbitrated loop-2 (FC-AL-2).pdf_第5页
第5页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Information technology Fibre channel Part 122: Arbitrated loop-2 (FC-AL-2)Amendment 1:2009 (IDT) toNational Standard of CanadaCAN/CSA-ISO/IEC 14165-122-06(ISO/IEC 14165-122:2005, IDT)NOT FOR RESALE.PUBLICATION NON DESTINE LA REVENTE.CSA Standards Update ServiceAmendment 1:2009 toCAN/CSA-ISO/IEC 1416

2、5-122-06October 2009Title: Information technology Fibre channel Part 122: Arbitrated loop-2 (FC-AL-2)Pagination: 7 pages (7 text)To register for e-mail notification about any updates to this publicationgo to www.ShopCSA.caclick on E-mail Services under MY ACCOUNTclick on CSA Standards Update Service

3、The List ID that you will need to register for updates to this publication is 2418306.If you require assistance, please e-mail techsupportcsa.ca or call 416-747-2233.Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.ISO/IEC 14165-122Edition 1

4、.0 2008-08INTERNATIONAL STANDARD Information technology Fibre channel Part 122: Arbitrated loop-2 (FC-AL-2) ISO/IEC 14165-122:2005/A1:2008(E)AMENDMENT 1 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2008 ISO/IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of thi

5、s publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions about ISO/IEC copyright

6、or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The Inte

7、rnational Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Pleas

8、e make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information

9、 on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds le

10、ading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv

11、 If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 ISO/IEC 14165-122Edition 1.0 2008-08INTERNATIONAL STANDARD Information technology Fibre chan

12、nel Part 122: Arbitrated loop-2 (FC-AL-2) INTERNATIONAL ELECTROTECHNICAL COMMISSION CICS 35.200 PRICE CODEAMENDMENT 1 2 14165-122 Amend. 1 ISO/IEC(E) FOREWORD Amendment 1 to International Standard ISO/IEC 14165-122 was prepared by subcommittee 25: Interconnection of information technology equipment,

13、 of ISO/IEC joint technical committee 1: Information technology. This International Standard has been approved by vote of the member bodies, and the voting results may be obtained from the address given on the second title page. This publication has been drafted in accordance with the ISO/IEC Direct

14、ives, Part 2. Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-0614165-122 Amend. 1 ISO/IEC(E) 3 INTRODUCTION to Amendment 1 Since the publication of ISO/IEC 14165-122:2005 (FC-AL) important technical corrections have been developed. FC-AL-2 defines a method for the operation of a FC arbitrated loop. Th

15、is amendment revises the base document, FC-AL-2, with respect to some inconsistencies found since approval of the base document. This amendment contains the following changes: the transmission word delay through an L_Port is changed from 6 words to 12 words to accommodate higher fibre channel speeds

16、; for example, 8 Gbit/s and 16 Gbit/s. the OPEN state is corrected to assure fairness for an L_Port that is using the TRANSFER state while another L_Port is using ARBf. Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-06 4 14165-122 Amend. 1 ISO/IEC(E) Page 34 8.0 Overview Replace the existing text of t

17、he second pagagraph (below the three dashed items) by the following: The maximum delay of a Transmission Word through an L_Port in the MONITORING or ARBITRATING state should not exceed twelve (12) Transmission Word periods. See 8.2.2 for maximum round trip latency and Annex A for L_Port Elasticity b

18、uffer management. Page 37 8.2.3 Loop timeout Replace the existing text of this subclause by the following new text: The Loop timeout value (LP_TOV) is 2 s. LP_TOV is used to keep a Loop from deteriorating due to protocol errors or lost Ordered Sets. For example, LP_TOV is used to reset the fairness

19、window (see 4.3) and during the INITIALIZATION process to time start-up events (see 10.5.4). Page 44 13 State 0 (MONITORING) actions Replace the third paragraph including its dashed items by the following new paragraph: If Idle is received, the CFW shall be modified as follows: if REPEAT is FALSE(0)

20、 and: if ARBf_SENT is FALSE(0), the CFW shall be set to Idle and ACCESS shall be set to TRUE(1) or if ARBf_SENT is TRUE(1), the CFW shall be set to ARB(FF) and ACCESS shall be set to TRUE(1). if REPEAT is TRUE(1), the CFW shall be set to Idle. Page 49 16 State 3 (OPEN) actions Replace the existing t

21、ext beginning with the NOTE below the first paragraph to, and including, the NOTE following the 10thparagraph by the following: NOTE 1 The six (6) Ordered Sets maintain the FC-FS spacing before SOF; R_RDYs allow the OPENED L_Port to transmit frame(s) without using BB_Credit. One R_RDY does not take

22、any extra bandwidth. The L_Port shall process, and shall not retransmit subsequent Transmission Words received on its inbound fibre. The L_Port shall transmit Primitive Signals, Primitive Sequences, or frames as specified in FC-PH (see 8.3.4). If Idle is received, the CFW shall be set to Idle and AC

23、CESS shall be set to TRUE(1). If ARB(F0) is received, the CFW shall be set to Idle and XMIT_2_IDLES shall be set to TRUE(1). Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-0614165-122 Amend. 1 ISO/IEC(E) 5 NOTE 2 Receiving ARB(F0) indicates that no other L_Port is now arbitrating (i.e., no L_Port chan

24、ged ARB(F0) to ARB(val). If ARB(FF) is received, the CFW shall be set to ARB(FF) and ACCESS shall be set to TRUE(1). If a Fill Word is to be transmitted, the CFW shall be used. NOTE 3 Since ARB_WON is TRUE(1) in this state, XMIT_2_IDLES will not be set to FALSE(0). If CLS is received, the LPSM shall

25、 make the transition to the RECEIVED CLOSE state (see item 9 and item 19). If MRKtx is received, where the MK_TP and AL_PS match the expected values, the action identified by MK_TP shall be performed. The received MRKtx shall not be retransmitted. If REPLICATE is TRUE(1) and the L_Port requests a br

26、oadcast replicate (REQ(open fr) or another selective replicate REQ(open yr), the LPSM shall transmit OPN(fr) or one OPN(yr) for each request at the next appropriate Fill Word, respectively. If ACCESS is TRUE(1) and the L_Port requests a transfer (REQ(transfer), the LPSM shall transmit CLS instead of

27、 the appropriate Fill Word and then shall make the transition to the TRANSFER state (see item 10 and item 20). If ACCESS is FALSE(0), the request to transfer is treated as a request to close. If a Class 1 connection exists, the L_Port shall remove the Class 1 connection before transmitting CLS; only

28、 the L_Port which received EOFdt shall transmit the first CLS. The LPSM may begin to close the Loop (REQ(close) or REQ(send DHD) by transmitting CLS or DHD instead of the next appropriate Fill Word. If CLS is transmitted, the LPSM shall make the transition to the XMITTED CLOSE state or the TRANSFER

29、state. If DHD is transmitted, the LPSM shall remain in the OPEN state, shall set DUPLEX to FALSE(0) and shall not transmit Data frames. If a Class 1 connection exists, the L_Port shall remove the Class 1 connection before transmitting CLS; only the L_Port which received EOFdt shall transmit CLS (see

30、 item 8 and item 18 or item 20). NOTE 4 Reasons for transmitting CLS or DHD include, but are not limited to: ARB(val) was detected to indicate that another L_Port is arbitrating (the OPEN L_Port may close the Loop at a convenient time); frame transmission is required with a different L_Port; the L_P

31、ort has not received any credit to transmit frames before a timeout occurred (an appropriate value would be AL_TIME since this L_Port is the originator of the Loop circuit); there are no additional frames to transmit to the other L_Port; or, the L_Port is making the transition to the Non-Participati

32、ng mode. Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-06 6 14165-122 Amend. 1 ISO/IEC(E) Page 61 Table 4 MONITORING (State 0) transitions Replace the first four sections of this table (the entire table on page 61) by the following new table: ACCESS := N/C ARB_PEND := 0 ARB_WON := 0 ARBf_SENT := 0 EN

33、TRY ACTIONS DUPLEX := 0 REPLICATE := 0 CFW := N/C DHD_RCV := N/C BYPASS := N/C XMIT_2_IDLES := N/C INPUT ACTION / OUTPUT NEXT STATE LOSS of SYNC. x CFW13MONITORING Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-0614165-122 Amend. 1 ISO/IEC(E) 7 Page 70 Table 7 OPEN (State 3) transitions Insert, in the

34、 section “PRIMITIVE SIGNALS,” a new row between the rows “ARB(F0) and “ARByx”, as follows: ARB(FF) CFW := ARB(FF) ACCESS := 1 FC-2 FP/PSig/PSeq OPEN Amendment 1:2009 toCAN/CSA-ISO/IEC 14165-122-06ICS 35.200 ISO/IEC 2008 All rights reserved Copyright NoticeThis Amendment to the International Standard

35、 contains information copyright protected by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC). Except as permitted under the laws of Canada, no extract of this Amendment to the International Standard may be reproduced, stored in any ret

36、rieval system, or transmitted in any form or by any means, electronic, photocopying, recording, or otherwise, without prior permission from the Standards Council of Canada (SCC). Requests for permission to reproduce this Amendment to the International Standard or parts thereof should be addressed to

37、 Manager, Technical Document Centre Standards Council of Canada 270 Albert Street, Suite 200 Ottawa, Ontario K1P 6N7 The Canadian adoption of this Amendment to the International Standard contains information copyright protected by the Canadian Standards Association. All rights reserved. No part of t

38、his adopted Amendment may be reproduced in any form whatsoever without the prior permission of the publisher. ISO/IEC material is reprinted with permission. Requests for permission to reproduce this adopted Amendment or parts thereof should be addressed to Manager, Sales Canadian Standards Associati

39、on 5060 Spectrum Way, Suite 100 Mississauga, Ontario L4W 5N6Copyright violators will be prosecuted to the full extent of the law.PRINTED IN CANADAIMPRIMEAU CANADA100%The Canadian Standards Association (CSA) prints its publications on Rolland Enviro100, which contains 100% recycled post-consumer fibre, is EcoLogo and Processed Chlorine Free certified, and was manufactured using biogas energy.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1