1、DEPARTMENT OF DEFENSE GUIDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FEN CI N G Department of the Army Guide Specification OCE GSH 2.13 Department of the Navy Guide Specification FAC GSH 2.13 Department of the Air Force Manual AFM 85-25, Sec. 2.13 Provided by IHSNot for ResaleNo reproduction or ne

2、tworking permitted without license from IHS-,-,-W 3515789 0014220 818 W 4270.21 - SPEC 2.13 N2 5 May 1985 GUIDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FENCING GENERAL NOTES The Departments of the Army, Navy and Air Force have collaborated in the preparation of this Guide Specificatan. Its conten

3、ts and arrangements conform generally to the (17) “CSI Masterformat - Master List of Section Titles and (25) Numbers (MP-2-l),“ 10 Mar 1983 of the Construction Speci- (17) fications Institute. (17) In accordance with the CSI Masterformat, identify each Section by a number and a letter (see Index of

4、Divisions and . Sections). The number will be that of the Division under which the Section is located. The letters following the number will begin with “A“ and continue alphabetically, as necessary USE AND INSTRUCTION: This Guide Specification shall be used in the preparation of project specificatio

5、ns for Military Family Housing in ac- cordance with current directives and instructions. It shall not be made a part of another specification by reference. Each project Architect- Engineer shall assure that complete coverage of the WOKK involved is specified, and shall further assure that Co-ordinat

6、ion with the drawings is accomplished. SELECTION OF MATERIALS: It is intended that architects and engineers for military family housing projects be permitted to select from this Guide Specification the materials and equipment which, in their professional judg- ment, are sui table for specif ic proje

7、cts. Contractor opinions included in this Guide Specification shall not be deleted unless economic and engineering evaluations indicate that the options are not justified for a specific project. Newly developed materials and methods not included in this Guide Specifica- tion may be used in limited a

8、pplication with prior clearance of the Military Departments involved. (Each Military Department shall ensure that prohibi- ted materials are not included in project specifications.) Such new materials or methods may not be used extensively until the quality and durability have been proven and approp

9、riate specifications have been included in this Guide Specification. In selecting the quality standards for materials and equipment, consideration should be given to the impact that certain materials may have on the construc- tion and maintenance cost of the over-all project. Notes, Page i - - -.* S

10、ection 2 “REMOVE - DO NOT INCLUDE NOTE SHEETS IN TE PROJECT SPECIFICATIONS“ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3515789 0014221 754 4270.21 - SPEC Jul 1, 66 GULDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FENCING Fencing will be located

11、 in $he project specifications as one of the Sections under Division 2 - “Site Work,“ and be numbered ac co r din gly . NOTES ON THE USE OF THIS SPECIFICATION SUGGESTIONS AND RECOMMENDA- TIONS: This section shall be included in the specifications when fencing is required for safety and/or screening

12、of a military family housing project. Security fencing is specifically ex- cluded from this section of the Mili- tary Family Housing Guide Specifica- tion s. The drawings shall incorporate a specific layout of fencing. Locations of straight-line and corner-post brac- ing shall be indicated. Requirem

13、ents of fence type, height of fence, swing of gates, and sizes shall be provided in layouts. For military family housing projects requiring security fencing for electri- cal substations or similar installations, the appropriate Departmental Guide Specification for security fencing util- ized in mili

14、tary construction projects shall be used as guidance. trical equipment fence enclosures are required, drawings shall provide for electrical clearances- between fence and equipment and wiring and equipment foundations to allow proper width for truck aisles. Where elec- If the area to be fenced has an

15、 irregular surface, drainage structures and fence line grading for rugged areas will be handled separately and the profile shall be included. This section may be expanded to include other types of fencing necessary for screen enclosures or unusual boundary conditions. Referenced Specifications: NOTE

16、 in the project specifica- tions, list the specifications and stand- ards by their current titles, numbers and letters. Inapplicable Mate rial: Delete materials not required. Chain Link Fencing: The .U standard height of chain - link fencing for military family hous- ing projects shall be 42 inches.

17、 When a specific .project requires a greater height for added safety, but not for security purposes, the height may be increased to 72 inches. Toprails or Wire: The toprails shall be deleted and a top tension wire substituted where appearance is not important or where the chain link fence is adja- c

18、ent to screen planting. A bottom reinforcing wire shall be specified with either a toprail or a top rein- forcing wire. Screen Fencing: Details for wood or masonry screening shall be completely indi- cated on the drawings, and the method of canstructian shall be accomplished in accordance with the a

19、ppropriate section of these specifications. Section 2 . , Notes, Page ii - iiMV- DU NOT INCLUDE NOTE SHEETS IN THE PROJECT SPECIFICATIONI Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-m 3515789 O014222 b90 4 8 4270.21 - SPEC 2.13 N2 5 May 1985 GUID

20、E SPECIFICATIONS FOR MILITARY FAMILY HOUSING SECTION 2 - FENCING f 1. SCOPE OF WORK: (A) WORK INCLUDED: This section includes fencing complete as indicated. 2. REFERENCED SPECIFICATIONS AND STANDARDS: (13) (A) APPLICABLE PUBLICATIONS: The publications listed below form a part (13) of this specificat

21、ion to the extent referenced. The publications are (13) referred to in the text by the basic designation only. (13) (1) Federal Specification: Fencing, Wire and Post Metal (And Gates, Chain-Link Fence Fabric, and Accessories) (General Specification). (2) American Society for Testing and Materials (A

22、STM): (14) A 123-78 Zinc (Hot-Galvanized) Coatings on Products Fabricated from Rolled, Pressed, and Forged Steel Shapes, Plates, Bars, and Strip. Zinc-Coated Steel Chain-Link Fence Fabric. Weight of Coating on Aluminum- Coated Iron or Steel Articles. Aluminum-Alloy Bar, Rod, and Wire (21) (3) Delete

23、d. , Page 1 - Section 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-il ,%, = m 3535789 0034223 527 m 4270.21 - SPEC 2.13 R1 /N2 2 February 1983 3. MATERIALS : FENCING (A) STANDARD PRODUCTS: Materials provided shall be standard catalog products of

24、 manufacturers regularly engaged in manufacture of products conforming to these specifications. (21) (BI CHAIN LINK FABRIC: Chain link fencing fabric shall be one of the following with a 2 inch mesh fabric height and edge finish as indicated: (21) (1) Galvanized Steel: Shall conform to ASTM A 392, 9

25、 gage. (12) (2) Aluminum-Coated Steel: Shall conform to ASTM A 392, (21) 9 gage, but aluminum coated with 0.40 ounce of aluminum per square foot of uncoated wire conforming to ASTM A 428. (12) (3) Aluminum-Alloy: Shall conform to ASTM A 392, 0.148 inch diameter, including gates, posts, toprails, hin

26、ges and latches. (Cl CONCRETE: Concrete shall conform to the requirements for 9 2,500 psi concrete at 28 days in accordance with Section - CONCRETE. (D 1 POSTS AND RAILS: Posts, rails, braces, gate frames, and (22) R-P-191 and shall be of type, size, and shape specified therein. accessories for stee

27、l fencing shall conform to Federal Specification All iron and steel parts shall be zinc-coated after fabrication with an average coating weight of 2.0 ounces of zinc per square foot of actual surf ace. (i) Aluminum-Coated Items: Shall conform to ASTM A 123. (21) (2) Aluminum-Alloy Items: Shall confo

28、rm to ASTM B 211. (1) Top and bottom reinforcing wire shall be of size indicated and shall have a minimum tensile strength of 80,000 pounds per square inch. For use with zinc-coated fabric, wire shall be zinc-coated with .80 ounce of zinc per square foot of wire surface. For use with aluminum- coate

29、d or aluminum-alloy fabric, wire shall be aluminum-coated with 0.40 ounce of aluminum per square foot of wire surface. (2) Hog rings for attaching fabric to top and bottom reinforc- ing wire shall be galvanized steel or aluminum wire of 0.110 inch diameter. Tie wire for attaching fabric to toprail o

30、r to intermediate posts shall be , Page 2 - Section 2 4U.S. Government Printing Office : 1983 - 381-277f1173 I; , f - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-i .i -. . - -. - 3. 3535789 0034224 463 4270.21 - SPEC 1 Jul 70 (Rev. 1) FENCING MAT

31、EWALS: (Continued) either 6 gauge zinc-coated steel wire preformed clips or O. 144 inch aluminum wire conforming to ASTM B211. (F) POST TOPS: Post tops shall be capped or of a type to accom- modate a toprail. (GI GATES: Gates shall be swing-type complete with latches, stops, keepers and hinges. 4. I

32、NSTALLATION: (A) GENERAL: (Chain link fence) (Wood screen fence) (Masonry screen fence) shall be installed to line and elevation as indicated. (Detailed instructions for erection of chain link fencing shall be furnished with the fence material by the fence manufacturer. ) . (BI EXCAVATION: Excavatio

33、n for posts and other concrete embedded items in other than bedrock shall be of the dimensions indicated. if. bedrock is encountered before reaching the required depth, the excava- tion shall be continued to the depth indicated or 18 inches intQ the bedrock, whichever is less, and shall be a minimum

34、 of 2 inches larger in diameter than the outside diameter of the post. Waste material from excavation shall be spread where directed. Post holes shall be cleared of loose material . (Cl POST SPACING: Line posts shall be spaced at intervals not to exceed 10 feet center to center. (Dl POST SETTING: Po

35、sts shall be set in holes of diameter and . depth indicated. (i) After post has been set and plumbed, hole shall be filled with concrete. Exposed surface of concrete shaQ be crowned to shed water. (2) For setting in solid rock, after post is set and plumbed, hole shall be filled with grout thoroughl

36、y worked into hole to eliminate voids. Grout shall be crowned to carry water from post. (3) Where solid rock is covered by an overburden of soil or loose rock, posts shall be set to .depth indicated. After post is set and plumbed, portion of hole in rock shall be filled with grout thoroughly worked

37、into hole and remaining part of hole in overburden shall be filled with concrete. Ekposed surface of concrete shall be crowned to shed water. - e- w. _- , Page 3 - Section 2 - _ - PROBLEM HARD COPY Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W 35

38、15789 0034225 3TT W 4270.21 - SPEC Jul 1, 66 a e a , FENCING 4. INSTALLATION: (Continued) (E) TERMINAL POSTS: End, corner, gate and pull posts shall be set as specified hereinbefore, and shall be braced to the nearest post with a galvanized pipe horizontal brace used as a compression member, and a g

39、alvanized 3/8 inch steel truss rod and truss tightener used as a tension member. braces are needed. all terminals. shall be considered as corners. changes in grade. On fences 3 to 5 feet in height where toprail is required, no Fences installed without toprail must have braces on All changes in direc

40、tion of fence line of 30 degrees or more Pullposts shall be used at all abrupt (F) POST TOPS: Post tops shall be installed as recommended by the manufacturer. (G) TOPRAILS: Toprails shall be installed prior to installation of chain link fabric and shall pass through intermediate post tops. shall be

41、round (tubular), shall be in lengths not less than 18 feet, and shall be fitted with couplings for connecting the lengths into a continuous run. The couplings shall be not less than 6 inches long, with O. 07 inch minimum wall thickness, and shall allow for expansion and contraction of the rail and s

42、hall be installed not to exceed 20 feet center to center. braced posts shall not exceed 500 feet. permitted only with a minimum wall thickness of O. 100 inch. or clips shall be provided in sufficient number for attaching the fabric securely to the toprail at intervals not exceeding 24 inches. be pro

43、vided for attaching the toprail to each gate, corner, pul.1 and eid post. Toprails Straight runs between Suitable ties Open seam outside sleeves shall be Meaas shall (H) (TOP AND)BOTTOM REINFORCING WIRES: (Top and) bottom reinforcing wires shall be installed prior to installation of chain link fabri

44、c and shall be pulled taut. of the (top and) bottom of the fabric. Each end, gate, corner, or pull post shall be equipped with a wire band, as indicated. Reinforcing wire shall be installed within 8 inches (I) STRETCHER BARS: Stretcher bars shall not be less than the Stretcher bars full height of th

45、e fabric with which they are to be used. shall be arranged for attaching fabric to all terminal posts by threading through the fabric, by b.ands, or by other positive mechanical means. stretcher bar shall be provided for each gate, and end post, and two for each corner and pull post. One (JI TIES OR

46、 CLIPS: Ties or clips of adequate strength shall be pro- vided in sufficient number for attaching the fabric to all line posts at in- tervals not exceeding 15 inches, and shall be provided for attaching rein- forcing wire to the fabric at intervals not exceeding 24 inches. , Page 4 - Section 2 Provi

47、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-a I a a = 3535789 0014226 236 4270.21 - SPEC Jul 1, 66 FENCING 4. INSTALLATION: (Continued) (K) BANDS OR CLIPS: Bands or clips of adequate strength shall be provided in sufficient number for attaching fabric

48、 and stretcher bars to all terminal posts at intervals not exceeding 15 inches. (L) CHAIN LINK FABRIC: Chain link fabric shall be installed on the side of the fence designated by the authorized Government representative, The fabric shall be stretched taut approximately 2 inches above the ground, and

49、 securely fastened to the posts. with stretcher bars and fabric bands spaced at maximum 15 inch intervals. Fastening to line posts shall be with tie wire, metal bands, or other approved method, attached at maximum 15 inch intervals. fastened to top (rail) (reinforcing wire) with wire ties or clips at intervals not exceeding 24 inches. reinforcing wire with wire ties or clips at intervals not exceeding 24 inches. Rol