1、CSA B45.8-13/IAPMO Z403-2013Terrazzo, concrete, and natural stone plumbing fixturesLegal Notice for Harmonized StandardJointly Developed by CSA and IAPMOIntellectual property rights and ownershipAs between Canadian Standards Association (operating as CSA Group) and International Association of Plumb
2、ing and Mechanical Officials (IAPMO) (collectively CSA Group and IAPMO) and the users of this document (whether it be in printed or electronic form), CSA Group and IAPMO are the joint owners of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to
3、the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. The unauthorized use, modification, copying, or disclosure of this document may violate laws that protec
4、t the intellectual property of CSA Group and IAPMO may give rise to a right in CSA Group and IAPMO to seek legal redress for such use, modification, copying, or disclosure. CSA Group and IAPMO reserve all intellectual property rights in this document.Disclaimer and exclusion of liabilityThis documen
5、t is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys in
6、tellectual property rights. CSA Group and IAPMO do not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group and IAPMO make no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.
7、IN NO EVENT SHALL CSA GROUP AND IAPMO, THEIR RESPECTIVE VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO
8、SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOC
9、UMENT, EVEN IF CSA GROUP OR IAPMO HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group and IAPMO are not undertaking to render professional or other services for or on behalf of any person or entity or to p
10、erform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group and IAPMO accept no responsibility whatsoever arising in any way from any and all
11、 use of or reliance on the information contained in this document. CSA Group and IAPMO have no power, nor do they undertake, to enforce compliance with the contents of the standards or other documents they jointly publish. Authorized use of this documentThis document is being provided by CSA Group a
12、nd IAPMO for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:. load this document onto a computer for the sole purpose of reviewing it;. search and browse this document; and. print this document if it
13、is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group and IAPMO to have such copies, and only if this Legal Notice appears on each such copy.In addition, users may not and may not permit others to. alter this docume
14、nt in any way or remove this Legal Notice from the attached standard;. sell this document without authorization from CSA Group and IAPMO; or. make an electronic copy of this document.If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this
15、 document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Standards Update ServiceCSA B45.8-13/IAPMO Z403-2013September 2013Title
16、: Terrazzo, concrete, and natural stone plumbing fixturesPagination: 33 pages (xi preliminary and 22 text), each dated September 2013To register for e-mail notification about any updates to this publicationgo to shop.csa.caclick on CSA Update ServiceThe List ID that you will need to register for upd
17、ates to this publication is 2422023.If you require assistance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at csagroup.org/legal to find out how we protect your personal information.TMA trade-mark of the Canadian Standards Association, operating as “
18、CSA Group”Published in September 2013 by CSA GroupA not-for-profit private sector organization5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044Visit the CSA Group Online Store at shop.csa.caThe IAPMO Group5001 East Philadelphia StreetOntario, California 91
19、761-2816, USA1-800-854-2766 1-909-472-4100Visit the IAPMO Online Store at www.IAPMOstore.orgCSA B45.8-13/IAPMO Z403-2013Terrazzo, concrete, and natural stone plumbing fixturesCSA/IAPMO StandardCommitment for AmendmentsThis Standard is issued jointly by the Canadian Standards Association (operating a
20、s “CSA Group”) and the International Association of Plumbing and Mechanical Officials (IAPMO). Amendments to this Standard will be made only after processing according to the Standards writing procedures of both CSA and IAPMO.Published in September 2013 by CSA GroupA not-for-profit private sector or
21、ganization5060 Spectrum Way, Suite 100Mississauga, Ontario, CanadaL4W 5N61-800-463-6727 416-747-4044Visit the CSA Online Store at shop.csa.caISBN 978-1-77139-168-9 2013 CSA GroupAll rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of
22、the publisher.The IAPMO Group5001 East Philadelphia StreetOntario, California 91761-2816USA1-800-854-2766 1-909-472-4100Visit the IAPMO Online Store atwww.IAPMOstore.orgCopyright 2013 by International Association of Plumbing and Mechanical OfficialsThe 2013 edition of this Standard is being issued w
23、ith an automatic addenda subscription service. The use of addenda allows revisions made in response to public review comments or committee actions to be published as necessary.September 2013 iiiContents 2013 CSA Group The IAPMO Group Terrazzo, concrete, and natural stone plumbing fixturesTechnical C
24、ommittee on Plumbing Fixtures (B45) vIAPMO Plumbing Standards Committee viiCSA/IAPMO Harmonization Task Group on Plumbing Fixtures ixPreface x0Introduction 11Scope 12 Reference publications 23 Definitions 34 General requirements 44.1 General 44.1.1 Tolerances 44.1.2 Coated parts 44.1.3 Different mat
25、erials 44.1.4 Accessible design fixtures 44.2 Waste fitting openings, drainage, and overflows 44.2.1 Openings and drainage 44.2.2 Overflows 44.3 Lavatories and sinks 54.3.1 Openings and mounting surfaces for supply fittings 54.4 Bathtubs and shower bases 54.4.1 Flanges 54.4.2 Minimum dimensions for
26、bathtubs 54.4.3 Shower base thresholds 54.4.4 Slip resistance 54.4.5 Factory-supplied supply fittings 64.5 Terrazzo 64.5.1 Composition 64.5.2 Fine aggregate 64.5.3 Coarse aggregate 64.5.4 Mix 64.5.5 Surface finish 65 Test procedures 65.1 Warpage tolerance test 65.1.1 Procedure 65.1.2 Performance 65.
27、2 Waste fitting connection test 75.2.1 Bathtubs and shower bases 75.2.2 Other fixtures 75.3 Point impact load test 75.3.1 Procedures 75.3.2 Performance 85.4 Colourfastness test 8 2013 CSA GroupCSA B45.8-13/IAPMO Z403-2013 The IAPMO Groupiv September 20135.4.1 Test Conditions 85.4.2 Procedure 85.4.3
28、Performance 85.5 Stain resistance test 95.5.1 Procedure 95.5.2 Rating 95.5.3 Performance 105.6 Cleanability and wear tests 105.6.1 Wear test 105.6.2 Cleanability test 115.6.3 Performance 125.7 Thermal shock resistance test 125.7.1 Specimen 125.7.2 Procedure 125.7.3 Performance 135.8 Field-installed
29、tiling-flange seal test 135.8.1 Procedure 135.8.2 Performance 135.9 Overflow test for sinks and lavatories 135.9.1 Procedure 135.9.2 Performance 136 Markings, packaging, and literature 136.1 General 136.2 Non-standard fixtures 146.3 Field-installed flanges 146.4 Packaging 146.5 Installation instruct
30、ions 14AnnexesA (informative) Unit conversion and rounding criteria 22Tables1 Scrub cycles 152 Brush switching schedule for scrub test 153 Thermal shock resistance test 15Figures1 Waste outlets dimensions 162 Opening and mounting surface dimensions for standard 200 mm (8 in) deck fittings 173 Openin
31、g and mounting surface dimensions for standard 200 mm (8 in) combination fittings 174 Opening and mounting surface dimensions for standard 100 mm (4 in) centre-set fittings 185 Opening and mounting surface dimensions for standard 200 mm (8 in) combination fittings 186 Opening and mounting surface di
32、mensions for single-mount supply fittings 197 Minimum dimensions for bathtubs 198 Waste fitting connection test 209 Wear test specimen 2010 Slip-resistant surface dimensions for bathtubs and shower bases 21 2013 CSA Group The IAPMO Group Terrazzo, concrete, and natural stone plumbing fixturesSeptemb
33、er 2013 vTechnical Committee on Plumbing Fixtures (B45)S. Rawalpindiwala Kohler Co.,Kohler, Wisconsin, USAChairF. Lemieux Health Canada, Ottawa, OntarioVice-ChairJ.E. Bertrand Moen Incorporated North Olmsted, Ohio, USAM. Campos International Code Council,Whittier, California, USAAssociateS.L. Cavana
34、ugh Cavanaugh Consulting, Santa Fe, New Mexico, USAI.W. Chang Intertek,Coquitlam, British ColumbiaAssociateM. Chojnacka City of Toronto, Toronto, OntarioN. Dickey CSA Group,Cleveland, Ohio, USAAssociateY. Duchesne Rgie du btiment du Qubec, Qubec, QubecT. Eberhardy Bradley Corporation, Menomonee Fall
35、s, Wisconsin, USAAssociateT.D. Ellison Cheffell Associates, Rockland, OntarioK. Ernst Oakville Stamping (b) provide an explanation of circumstances surrounding the actual field condition; and(c) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the is
36、sue.Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are available on the Current Standards Activities page at standardsactivities.csa.ca.(5) This Standard is subject to review five years from the date of publication. Suggesti
37、ons for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquiriescsagroup.org and include “Proposal for change” in the subject line:(a) Standard designation (number);(b) relevant clause, table, and/or figure num
38、ber;(c) wording of the proposed change; and(d) rationale for the change.(6) Attention is drawn to the possibility that some of the elements of this Standard may be the subject of patent rights. CSA is not to be held responsible for identifying any or all such patent rights. Users of this Standard ar
39、e expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.IAPMO Notes: (1) The use of the singular does not exclude the plural (and vice versa) when the sense allows. (2) This standard was developed in accordance with the IAPMO procedures a
40、ccredited as meeting the criteria for American National Standards and it is an American National Standard. The IAPMO Standards Committee that approved this Standard was balanced to assure that individuals from competent and concerned interests had an opportunity to participate. During its developmen
41、t, this Standard was made available for public review, thus providing an opportunity for additional input from industry, academia, regulatory agencies, and the public at large. (3) This Standard was developed by consensus, which is defined as substantial agreement; consensus implies much more than a
42、 simple majority, but not necessarily unanimity. It is consistent with this definition that a member of the relevant IAPMO Standards Committee can be included in the committee roster and yet not be in full agreement with all sections of this Standard.(4) Although the intended primary application of
43、this Standard is stated in its scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose. 2013 CSA Group The IAPMO Group Terrazzo, concrete, and natural stone plumbing fixturesSeptember 2013 xi(5) IAPMO Standa
44、rds are subject to periodic review and suggestions for their improvement will be referred to the relevant IAPMO Standards Committee. To submit a proposal for change to this Standard, you may send the following information to the International Association of Plumbing and Mechanical Officials, Attenti
45、on Standards Department, 5001 East Philadelphia Street, Ontario, California, 91761, and include “Proposal for change” in the subject line:(a) standard designation (number);(b) relevant section, table, or figure number, as applicable;(c) wording of the proposed change, tracking the changes between th
46、e original and the proposed wording; and(d) rationale for the change.(6) Requests for interpretation should be clear and unambiguous. To submit a request for interpretation of this Standard, you may send the following information to the International Association of Plumbing and Mechanical Officials,
47、 Attention Standards Department, 5001 East Philadelphia Street, Ontario, California, 91761, and include “Request for interpretation” in the subject line:(a) the edition of the standard for which the interpretation is being requested;(b) the definition of the problem, making reference to the specific
48、 section and, when appropriate, an illustrative sketch explaining the question;(c) an explanation of circumstances surrounding the actual field conditions; and(d) the request for interpretation phrased in such a way that a “yes” or “no” answer will address the issue.(7) Interpretations are processed
49、 in accordance with IAPMOs accredited standards development procedures. IAPMO issues written replies to inquiries concerning interpretation of technical aspects of this Standard. (8) IAPMO accepts responsibility only for those interpretations of this Standard issued in accordance with the accredited IAPMO policies and procedures, which precludes the issuance of interpretations by individuals.(9) IAPMO does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.(10)IAPMO does not take any posit