1、C22.2 No. 0.5-16Threaded conduit entriesLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied vi

2、ewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis docu

3、ment is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys

4、 intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation.IN NO EVENT SH

5、ALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOS

6、T REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADV

7、ISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another pe

8、rson or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.C

9、SA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownershipAs between CSA Grou

10、p and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that ma

11、y be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others intellectual

12、 property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the possib

13、ility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own

14、 responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form: load this document onto a computer for the sole purpose

15、of reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.In a

16、ddition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and conditions con

17、tained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Standards Upda

18、te ServiceC22.2 No. 0.5-16January 2016Title: Threaded conduit entriesTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2424130.If you require assistance,

19、 please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.ISBN 978-1-4883-0206-0 2016 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoeve

20、r without the prior permission of the publisher.Published in January 2016 by CSA Group A not-for-profit private sector organization 178 Rexdale Boulevard, Toronto, Ontario, Canada M9W 1R3 To purchase standards and related publications, visit our Online Store at shop.csa.caor call toll-free 1-800-463

21、-6727 or 416-747-4044.TMA trade-mar k of the Canadian S tandards Association, operating as “CSA Group”Threaded conduit entriesC22.2 No. 0.5-16C22.2 No. 0.5-16 Threaded conduit entriesJanuary 2016 2016 CSA Group1ContentsTechnical Committee on General Requirements, CE Code, Part II 2Subcommittee on Th

22、readed Conduit Entries 4Preface 51 Scope 62 Reference publications 63 Definitions 74 Construction 74.1 General 74.2 Thread form 74.3 Dimensions of conduit entries 74.3.1 Depth 74.3.2 Threaded length 84.3.3 Pitch diameter 84.3.4 Throat diameter 84.4 Protection for conductor insulation 85 Inspection 8

23、5.1 Pitch diameter 8C22.2 No. 0.5-16 Threaded conduit entriesJanuary 2016 2016 CSA Group2Technical Committee on General Requirements, CE Code, Part IIG. Lobay CSA Consumer Network, Kars, Ontario Category: General InterestChairR.J. Kelly Government of Nunavut-Dept of Community b) provide an explanati

24、on of circumstances surrounding the actual field condition; andc) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue. Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and a

25、re available on the Current Standards Activities page at standardsactivities.csa.ca.5) This Standard is subject to review five years from the date of publication and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the follow

26、ing information to inquiriescsagroup.org and include “Proposal for change” in the subject line: a) Standard designation (number);b) relevant clause, table, and/or figure number;c) wording of the proposed change; andd) rationale for the change.C22.2 No. 0.5-16 Threaded conduit entriesJanuary 2016 201

27、6 CSA Group6C22.2 No. 0.5-16Threaded conduit entries1 Scope1.1 This Standard applies to equipment for installation and use in accordance with the Rules of the Canadian Electrical Code, Part I, other than conduit couplings.1.2 This Standard includes basic construction and inspection requirements for

28、the threaded entry for conduit into an electrical enclosure in order to assure the following:a) the adequacy of a grounding path provided by rigid metal conduit in accordance with the Rules ofthe Canadian Electrical Code, Part I; andb) that threaded conduit entries are unlikely to cause damage to th

29、e insulation of conductors that areinstalled in a raceway of rigid metal conduit in accordance with the Rules of the Canadian Electrical Code, Part I.Note: In Clause 1.2 the word “enclosure” is used to include a variety of structures with an enclosing function, whether constituting part of a raceway

30、 or an enclosure (of a switch, for example).1.3 This Standard does not include requirements for construction material, design proportions, protection against corrosion, and other matters that are more appropriately included in the scope of individual Standards applicable to specific equipment.1.4 In

31、 this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permis

32、sible within the limits of the Standard.Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.Notes to tables and figures are considered part of the table or fig

33、ure and may be written as requirements.Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.2 Reference publicationsThis Standard refers to the following publications, and where such reference is made, it shall be to the edition listed below:C22.2 N

34、o. 0.5-16 Threaded conduit entriesJanuary 2016 2016 CSA Group7CSA GroupC22.1-15 Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0-10 (R2015) General Requirements Canadian Electrical Code, Part IIANSI/ASME (American National Standards Institute/American Society of Mechanical Engineers)B1.13M-2005 M

35、etric Screw Threads: M ProfileB1.16M-1984 Gages and Gaging for Metric M Screw ThreadsB1.20.1-2013 Pipe Threads, General Purpose (Inch)3 DefinitionsThe following definitions shall apply in this Standard:Integral bushing a constriction in a threaded conduit entry designed to provide a well rounded sur

36、face over which conductors may be drawn without injury to the insulation.Threaded conduit entry a conduit entry that is threaded so as to secure a rigid conduit without the use of a bushing or locknut.4 Construction4.1 GeneralGeneral requirements applicable to this Standard are given in CAN/CSA-C22.

37、2 No. 0.The construction of a threaded conduit entry shall conform to one of the types illustrated in Figures 1, 2, 3, or 4.4.2 Thread formThe threading of conduit entries shall be:a) a tapered pipe thread conforming to Section 2 of ANSI B1.20.1; orb) straight pipe threads conforming to ANSI/ASME B1

38、.13M.4.3 Dimensions of conduit entries4.3.1 DepthThe minimum depth of a conduit entry that includes an integral bushing shalla) for enclosures requiring a thread length per Clause 4.3.2 b) i) and iii), comply with the requirements of Table 2; orb) for enclosures requiring a thread length per Clause

39、4.3.2 b) ii), comply with the requirements of Table 3.C22.2 No. 0.5-16 Threaded conduit entriesJanuary 2016 2016 CSA Group8The minimum depth of conduit entry, as listed in column 2 of Tables 2 and 3, is the total of L1*, plus 2 times the pitch of the thread, plus the manufacturers female thread tole

40、rance.* L1 is the length from the gauging notch to the small end of a working plug gauge complying with Section 7of ANSI B1.20.1. “Plus the sum of 2 times the pitch of the thread” allows for one turn for the maximum conduit thread tolerance and one turn for wrench tight.The maximum and minimum femal

41、e thread tolerances shall be as specified in Clause 5.1.3.Where the threaded portion (tapping land) of an entry is chamfered or counterbored, the depth of the entry shall be measured from a plane located at the intersection of the chamfer or counterbore with the pitch cone of the thread.Note: For me

42、tric plug gauges, see ANSI/ASME B1.16M.4.3.2 Threaded lengthThe minimum axial length of the threaded portion of a conduit entry (tapping land) shall be the greater of Item a) or b) (see Figures 2 and 4) as follows:a) 1/4 in; orb) alternatively: i) 5 the pitch of the thread for Class I, Division 1 en

43、closures;ii) 3 the pitch of the thread for other than Class I, Division 1 or Zone enclosures; oriii) 4.5 to 5 the pitch of the thread for Zones (See Section 18 of the Canadian Electrical Code, Part I).4.3.3 Pitch diameterThe pitch diameter of the thread in a conduit entry shall comply with the inspe

44、ction requirements in Clause 5.4.3.4 Throat diameterThe throat diameter of an integral bushing shall be in accordance with Table 1.4.4 Protection for conductor insulation4.4.1 An integral bushing in a conduit entry shall have a smooth surface with no sharp edges at the throat.4.4.2 A conduit entry t

45、hat does not have an integral bushing and has an axial length in excess of that required by Clause 4.3.2 shall be smooth and rounded and free from sharp edges at the small end (see Figure 3).5 Inspection5.1 Pitch diameter5.1.1 Conformity of threading to the pitch diameter requirement shall be determ

46、ined by a working gauge, complying with Section 7 of ANSI B1.20.1 or ANSI/ASME B1.16M, in hand-tight engagement with the part being inspected.C22.2 No. 0.5-16 Threaded conduit entriesJanuary 2016 2016 CSA Group95.1.2 The gauging shall be done on parts that have clean, undamaged threads after any pro

47、tective coating has been applied. A pipe plug or conduit nipple having a minimum thread tolerance* shall be wrench tightened into the entry and removed prior to gauging.* Plus 1 turn on NPT ring gauge.Notes: 1) Where the threaded portion (tapping land) of an entry is chamfered or counterbored, the p

48、osition of a gauge in relation to an end (either large or small) thereof is referred to a plane located at the intersection of the chamfer or counterbore with the pitch cone of the thread.2) For metric plug gauges see ANSI/ASME B1.16M.5.1.3 A conduit entry shall be considered to comply with the pitc

49、h diameter requirements, provided the position of a gauge (as specified in Clauses 5.1.1 and 5.1.2) conforms to the following limits. In a conduit entry having a threaded portion (tapping land) of a length to produce thread conforming to the length requirements for an internal tapered pipe thread, as described in Section 2 of ANSI B1.20.1, the gauging notch of the NPT gauge is a minimum of a) +1/2 turn for enclosures requiring a thread length per Clause 4.3.2 b) i); orb) 1-1/4 turns for enclosures requiring a thread length per Clause 4.3.2 b) ii);to

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1