CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf

上传人:李朗 文档编号:621192 上传时间:2018-12-21 格式:PDF 页数:152 大小:1.45MB
下载 相关 举报
CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf_第1页
第1页 / 共152页
CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf_第2页
第2页 / 共152页
CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf_第3页
第3页 / 共152页
CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf_第4页
第4页 / 共152页
CSA C22 2 NO 111-2010 General-use snap switches (Fourth Edition Update No 1 February 2012).pdf_第5页
第5页 / 共152页
点击查看更多>>
资源描述

1、C22.2 No. 111-10General-use snap switchesLegal Notice for StandardsCanadian Standards Association (CSA) standards are developed through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied viewpoints and in

2、terests to achieve consensus and develop a standard. Although CSA administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis document is provided with

3、out any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys intellectual propert

4、y rights. CSA does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation. IN NO EVENT SHALL CSA, ITS VOLUNTEERS, MEMBERS

5、, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST

6、 OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJ

7、URY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this document i

8、s directed to those who have the appropriate degree of experience to use and apply its contents, and CSA accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document. CSA is a private not-for-profit company that publishes v

9、oluntary standards and related documents. CSA has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs between CSA and the users of this document (whether it be in printed or electronic

10、 form), CSA is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secr

11、ets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSAs and/or others intellectual property and may give rise to a right in CSA and/or others to seek legal redress fo

12、r such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA shall

13、not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.Authorized use of this documentThis document is being provided by CSA for informationa

14、l and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:.load this document onto a computer for the sole purpose of reviewing it;.search and browse this document; and.print this document if it is in PDF format. Limited co

15、pies of this document in print or paper form may be distributed only to persons who are authorized by CSA to have such copies, and only if this Legal Notice appears on each such copy.In addition, users may not and may not permit others to.alter this document in any way or remove this Legal Notice fr

16、om the attached standard;.sell this document without authorization from CSA; or.make an electronic copy of this document.If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if yo

17、u do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Update No. 1C22.2 No. 111-10February 2012Note: General Instructions for CSA Standards are now called Updates. Please contact CSA Info

18、rmation Products Sales or visit shop.csa.ca for information about the CSA Standards Update Service.Title: General-use snap switches originally published May 2010The following revisions have been formally approved and are marked by a vertical line in the margin on the attached replacement pages:Revis

19、ed Copyright page, Preface, Clauses 5.1.1, 5.2.1, 5.5.3, 5.21.3, 5.24, 5.25.1, 5.26.1, 7.1.1, 7.3.2, and 8.2.4.2 and Annex ANew Clauses 2.8.1, 2.8.2, 2.18, 4.4.2.7, 4.4.2.8, 4.5A, 5.1.4, 5.2.12.1, 5.20.2, 5.21.1.1, 5.25.1.1, 5.28, 5.29, 7.1.5.1, 7.1.6.1, and 7.2.4 and Figure 6Deleted None Update you

20、r copy by inserting these revised pages.Keep the pages you remove for reference.Canadian Standards AssociationCSA-C22.2 No. 11110Fourth EditionUnderwriters Laboratories Inc.UL 20Thirteenth EditionGeneral-Use Snap SwitchesMay 10, 2010(Title Page Reprinted: February 17, 2012)ANSI/UL 202012Commitment f

21、or AmendmentsThis standard is issued jointly by the Canadian Standards Association (CSA) and UnderwritersLaboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may besubmitted to CSA or UL at any time. Revisions to this standard will be made only after processingacco

22、rding to the standards development procedures of CSA and UL. CSA and UL will issue revisionsto this standard by means of a new edition or revised or additional pages bearing their date of issue.ISBN 978-1-55491-403-6 2010 Canadian Standards AssociationAll rights reserved. No part of this publication

23、 may be reproduced in any form whatsoever without theprior permission of the publisher.CSA Standards are subject to periodic review, and suggestions for their improvement will be referredto the appropriate committee. To submit a proposal for change to CSA Standards, please send thefollowing informat

24、ion to inquirescsa.ca and include Proposal for change in the subject line:Standard designation (number); relevant clause, table, and/or figure number; wording of the proposedchange; and rationale for the change.To purchase CSA Standards and related publications, visit CSAs Online Store at shop.csa.c

25、a or calltoll-free 1-800-463-6727 or 416-747-4044.Copyright 2012 Underwriters Laboratories Inc.ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standardshould be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regardingtho

26、se Standards shall remain the sole and exclusive property of UL.This ANSI/UL Standard for Safety consists of the Thirteenth Edition including revisions throughFebruary 17, 2012. The most recent designation of ANSI/UL 20 as an American National Standard(ANSI) occurred on February 15, 2012. ANSI appro

27、val for a standard does not include the Cover Page,Transmittal Pages, Title Page (front and back), or the Preface. The National Difference Page and IECForeword are also excluded from the ANSI approval of IEC-based standards.The Department of Defense (DoD) has adopted UL 20 on December 4, 1981. The p

28、ublication of revisedpages or a new edition of this Standard will not invalidate the DoD adoption.Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative StandardsDevelopment

29、System (CSDS) at http:/.To purchase UL Standards, visit Comm 2000 at http:/m- call toll-free 1-888-853-3503.CONTENTSPreface .51 Scope .72 Definitions 83 General 8A3.1 Components 8A3.2 Units of Measurement .8B3.3 Reference Publications .104 Construction .124.1 Enclosure 124.2 Lining 134.3 Bushings an

30、d Strain Relief .144.4 Bases and Bodies .144.5 Current-Carrying Parts .164.5A Separable Jumper Connector for Separable Terminals 20A4.6 Separable Terminal Assembly 214.7 Insulating Material .214.8 Actuating Members 224.9 Creepage Distances, Clearances, and Distances Through Sealing Compounds .224.10

31、 Assembly .244.11 Provision for Grounding .255 Testing .265.1 General 265.2 Test Sequence 26A5.3 Tungsten-Filament-Lamp Load Characteristics 335.4 Assembly Test 355.5 Test Conditions .365.6 Overload Test .365.7 Endurance Test .395.8 Temperature Test .405.9 Dielectric Voltage-Withstand Test 425.10 Se

32、curity of Switch Leads Test .435.11 Push-In Terminal Tests .435.12 Effect of Heat on Actuating Members Test 445.13 Switching Mechanism Test 445.14 Strain-Relief Test .465.15 Fault Current Test 465.16 Crushing Test 475.17 Resistance to Heat Test .475.18 Door Switch Assembly Test .475.19 Retention of

33、Tab Connection Test 475.20 Separable Connector Pull Test .485.21 Mold Stress Relief Test .485.22 Separable Terminal Assembly Humidity Conditioning Followed By Dielectric Test 495.23 Short Circuit Withstand Test 495.24 Latching Mechanism Test .505.25 Abnormal Overload Test 515.26 Temperature Test 525

34、.27 Continuity Impedance Test 525.28 Bonding (Fault Current) Test .52FEBRUARY 17, 2012 CSA-C22.2 NO. 11110 UL 20 35.29 Mounting Yoke Resistance Test 52A6 Ratings 52A7 Markings 52B7.1 General .52B7.2 Supplementary Markings .547.3 Location 567.4 Tungsten 56A7.5 AC-Only Identification 577.6 Switch Term

35、ination Restrictions .578 Self-Contained Switches for Use Without a Separate Outlet Box .598.1 General 598.2 Construction 598.3 Performance Testing .628.4 Markings and Instructions 69ANNEX A (Normative)Standards for ComponentsA1 Component Standards 74Annex B (Informative)Canadian Requirements for CO

36、/ALR SwitchesB1 General .75B2 Heat Cycling with Wire Disturbance .77B3 Heat Cycling with Vibration 78B4 Environmental 79B5 Stripping Torque 80FEBRUARY 17, 2012CSA-C22.2 NO. 11110 UL 204PrefaceThis is the harmonized CSA and UL Standard for General-Use Snap Switches. It is the fourth edition ofCSA C22

37、.2 No.111 and the thirteenth edition of UL 20. This edition of CSA C22.2 No. 111 supersedesthe previous edition published in 2000.This harmonized Standard was prepared by the Canadian Standards Association (CSA) and UnderwritersLaboratories Inc. (UL). The efforts and support of NEMA (National Electr

38、ical Manufacturers Association),EFC (Electro-Federation of Canada), and the CANENA Technical Harmonization Committee are gratefullyacknowledged.This Standard is considered suitable for use for conformity assessment within the stated scope of theStandard.This standard was reviewed by the CSA Integrat

39、ed Committee on Wiring Devices for Household andGeneral Use, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSAStrategic Steering Committee on Requirements for Electrical Safety, and has been formally approved bythe CSA Technical Committee.This standard has been app

40、roved by the American National Standards Institute (ANSI) as an AmericanNational Standard.Where reference is made to a specific number of samples to be tested, the specified number shall beconsidered a minimum quantity.Note: Although the intended primary application of this standard is stated in its

41、 scope, it is important to note that it remainsthe responsibility of the users of the standard to judge its suitability for their particular purpose.Level of HarmonizationThis standard is published as an equivalent standard. An equivalent standard is a standard that issubstantially the same in techn

42、ical content, except as follows. Technical national differences are allowedfor codes and governmental regulations and those recognized as being in accordance with NAFTA Article905, for example because of fundamental, climatic, geographical, technological, or infrastructural factors,scientific justif

43、ication, or the level of protection that the country considers appropriate. Presentation is wordfor word except for editorial changes.InterpretationsThe interpretation by the standards development organization of an identical or equivalent standard isbased on the literal text to determine compliance

44、 with the standard in accordance with the proceduralrules of the standards development organization. If more than one interpretation of the literal text has beenidentified, a revision is to be proposed as soon as possible to each of the standards developmentorganizations to more accurately reflect t

45、he intent.CSA Effective DateThe effective date for CSA International will be announced through CSA Informs or a CSA certificationnotice.FEBRUARY 17, 2012 CSA-C22.2 NO. 11110 UL 20 5UL Effective DateAs of February 17, 2012, all products Listed, Recognized, or Classified by UL must comply with therequ

46、irements in this Standard and is not part of the ANSI approved standard.A UL effective date is one established by Underwriters Laboratories Inc.FEBRUARY 17, 2012CSA-C22.2 NO. 11110 UL 2061 Scope1.1 The requirements of this Standard apply to manually operated, general-use snap switches forconnection

47、to copper (Cu) or copper-clad conductors used in accordance with the National ElectricalCode(NEC), ANSI/NFPA 70, or the Canadian Electrical Code (CEC), Part I, and intended for connectionto wiring systems recognized by the NEC or the CEC, Part I. In Canada, requirements for switches forconnection to

48、 aluminum (Al) conductors used in accordance with the CEC, Part I, and intended forconnection to wiring systems recognized by the CEC, Part I, are covered in Annex B.1.2 This Standard applies to ac/dc rated switches for which the load ratings do not exceed 60 A at 250V or less, 30 A at 251 V 600 V,

49、and 2 hp at 125 V 600 V or less. This Standard also covers ac-onlyrated switches for which the load ratings do not exceed 30 A at 347 Vac or less.1.3 This Standard applies to switches constructed to be installed readily in a flush device box or on anoutlet-box cover and intended for connection to branch-circuit wiring.1.4 This Standard applies to pendant and through-cord switches intended for field installation on flexiblecord and provided with one “on” and one “off” position.1.5 This Standard applies to

展开阅读全文
相关资源
猜你喜欢
  • STAS 12415 1-1986 Hydraulic fluid power PHD 1 TYPE GEAR PUMPS Basic dimensions《液压流体动力PHD1型齿轮泵基本参数 》.pdf STAS 12415 1-1986 Hydraulic fluid power PHD 1 TYPE GEAR PUMPS Basic dimensions《液压流体动力PHD1型齿轮泵基本参数 》.pdf
  • STAS 12416 1-1986 Hydraulic fluid power D1KI-XTIONAL CONTHOJ SLIDK VALVES p S15 bar CJasification and symbols《液压流体动力 方向控制 滑阀 p S15杆分类和符号 》.pdf STAS 12416 1-1986 Hydraulic fluid power D1KI-XTIONAL CONTHOJ SLIDK VALVES p S15 bar CJasification and symbols《液压流体动力 方向控制 滑阀 p S15杆分类和符号 》.pdf
  • STAS 12416 2-1986 Hydraulic fluid power DIRECTIONAL CONTROL S1LDE VALVES p 315 bar size 05 Types and basic dimensions《液压流体动力 方向控制滑阀p 315杆,尺寸05类型和基本尺寸 》.pdf STAS 12416 2-1986 Hydraulic fluid power DIRECTIONAL CONTROL S1LDE VALVES p 315 bar size 05 Types and basic dimensions《液压流体动力 方向控制滑阀p 315杆,尺寸05类型和基本尺寸 》.pdf
  • STAS 12416 3-1990 Hydrostatic drives SLIDK VAL-VES NP 315 bar ND 6 Typos and main dimensioi s《静压驱动滑阀NP315杆,ND6类型和主要参数 》.pdf STAS 12416 3-1990 Hydrostatic drives SLIDK VAL-VES NP 315 bar ND 6 Typos and main dimensioi s《静压驱动滑阀NP315杆,ND6类型和主要参数 》.pdf
  • STAS 12416 4-1990 Hydrostatic drives SLIDE'VALVES NP 315 bar ND 16 Types and main dimensions《静压驱动 滑阀NP315 杆,ND32类型和主要尺寸 》.pdf STAS 12416 4-1990 Hydrostatic drives SLIDE'VALVES NP 315 bar ND 16 Types and main dimensions《静压驱动 滑阀NP315 杆,ND32类型和主要尺寸 》.pdf
  • STAS 12416 5-1990 Hydrostatic drives slide valnes np 315 bar.ND 20Types and main dimensions《静压驱动滑阀,NP315杆ND20类型和主要尺寸 》.pdf STAS 12416 5-1990 Hydrostatic drives slide valnes np 315 bar.ND 20Types and main dimensions《静压驱动滑阀,NP315杆ND20类型和主要尺寸 》.pdf
  • STAS 12416 6-1990 Hydrostatic drives SLIDE VALVES NP 315 bar ND 32 Types and main dimensions《静压驱动滑阀NP315 杆,ND32类型和主要尺寸 》.pdf STAS 12416 6-1990 Hydrostatic drives SLIDE VALVES NP 315 bar ND 32 Types and main dimensions《静压驱动滑阀NP315 杆,ND32类型和主要尺寸 》.pdf
  • STAS 12417 0-1986 Hydraulic power PRESSURE CONTROL VALVES pn 315 bar Gasification and symbols《水力压力控制阀PN315杆的分类和符号 》.pdf STAS 12417 0-1986 Hydraulic power PRESSURE CONTROL VALVES pn 315 bar Gasification and symbols《水力压力控制阀PN315杆的分类和符号 》.pdf
  • STAS 12417 1-1986 Hydraulic fluid power PILOT OPERATED PRESSURE CONTROL VALVES p 315 bar TYPE SPP Basic dimensions《液压液体动力 飞行员操作压力控制阀p 315杆 类型和基本参数 》.pdf STAS 12417 1-1986 Hydraulic fluid power PILOT OPERATED PRESSURE CONTROL VALVES p 315 bar TYPE SPP Basic dimensions《液压液体动力 飞行员操作压力控制阀p 315杆 类型和基本参数 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1