CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf

上传人:outsidejudge265 文档编号:629584 上传时间:2018-12-22 格式:PDF 页数:34 大小:476.63KB
下载 相关 举报
CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf_第1页
第1页 / 共34页
CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf_第2页
第2页 / 共34页
CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf_第3页
第3页 / 共34页
CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf_第4页
第4页 / 共34页
CLC TS 50430-2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes《光缆 燃气管道电缆 高压燃气管道电缆的系列规范》.pdf_第5页
第5页 / 共34页
点击查看更多>>
资源描述

1、DRAFT FOR DEVELOPMENT DD CLC/TS 50430:2005 Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes ICS 33.180.10 DD CLC/TS 50430:2005 This Draft for Development was published under the authority of the Standards Policy and Strategy Committee on

2、 23 February 2005 BSI 23 February 2005 ISBN 0 580 45568 8 National foreword This Draft for Development is the official English language version of CLC/TS 50430:2005. This publication is not to be regarded as a British Standard. It is being issued in the Draft for Development series of publications a

3、nd is of a provisional nature because the technology is still at a developmental stage. It should be applied on this provisional basis, so that information and experience of its practical application may be obtained. Comments arising from the use of this Draft for Development are requested so that U

4、K experience can be reported to the European organization responsible for its conversion to a European Standard. A review of this publication will be initiated 2 years after its publication by the European organization so that a decision can be taken on its status at the end of its 3-year life. Noti

5、fication of the start of the review period will be made in an announcement in the appropriate issue of Update Standards. According to the replies received by the end of the review period, the responsible BSI Committee will decide whether to support the conversion into a European Standard, to extend

6、the life of the Technical Specification or to withdraw it. Comments should be sent in writing to the Secretary of BSI Subcommittee GEL/86/1, Optical fibres and cables, at 389 Chiswick High Road, London W4 4AL, giving the document reference and clause number and proposing, where possible, an appropri

7、ate revision of the text. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the secti

8、on entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. Summary of pages This document comprises a front cover, an inside front cover, the CLC/TS title page, pages 2 to 31 and a back cover. The BSI

9、copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsTECHNICAL SPECIFICATION CLC/TS 50430 SPECIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2005 CENELEC European Committee for Electrotechnical Stand

10、ardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TS 50430:

11、2005 E ICS 33.180.10 English version Optical fibre cables Gas pipe cables Family specification for cables to be installed in high pressure gas pipes Lichtwellenleiterkabel Kabel fr Gasleitungen Familienspezifikation fr Kabel zu Montage in Hochdruckgasleitungen This Technical Specification was approv

12、ed by CENELEC on 2004-09-11. CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the natio

13、nal electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Ki

14、ngdom. CLC/TS 50430:2005 - 2 - Foreword This Technical Specification was prepared by the Technical Committee CENELEC TC 86A, Optical fibres and optical fibre cables. The text of the draft was submitted to the vote and was approved by CENELEC as CLC/TS 50430 on 2004-09-11. The following date was fixe

15、d: latest date by which the existence of the CLC/TS has to be announced at national level (doa) 2005-03-11 _ - 3 - CLC/TS 50430:2005 Contents Page 1 Scope.5 2 Normative references.5 3 Symbols.6 4 Family specification for gas pipe cables and sub-ducts for installation by blowing and/or pulling/draggi

16、ng in/into gas pipes (blank detail specification and minimum requirements)7 4.1 Construction.7 4.1.1 General7 4.1.2 Sub-ducts7 4.1.3 Gas pipe cables .7 4.2. Product descriptions 8 4.2.1 Gas pipe cables description .8 4.2.1.1 Cable for installation within sub-ducts (previously installed into the gas

17、pipe in between two adjacent I/O-ports) 8 4.2.1.2 Cables for direct installation into the gas pipe 9 4.2.2 Sub-duct description10 4.3 Optical fibres11 4.3.1 Single-mode dispersion unshifted (B1.1) optical fibre.11 4.3.2 Single-mode dispersion shifted (B2) optical fibre11 4.3.3 Single-mode non-zero d

18、ispersion (B4) optical fibre11 4.3.4 Multimode fibres 12 4.4 High pressure gas pipe cable constructions.12 4.4.1 Cable for installation within sub-ducts (previously installed within high pressure gas pipe)12 4.4.2 Cable for direct installation within high pressure gas pipe 13 4.4.3 Sub-duct construc

19、tion14 4.5 Installation and operating conditions 14 4.5.1 Tests applicable to cables/cable elements .14 4.5.2 Installation conditions.14 4.6 Mechanical and environmental tests 15 4.6.1 Sub-ducts15 4.6.1.1 Tests applicable.15 4.6.1.2 Details of family requirements and test conditions for sub-ducts 16

20、 4.6.1.2.1 Pressure16 4.6.1.2.2 Tensile performance16 4.6.1.2.3 Kink16 4.6.1.2.4 Crush.17 4.6.1.2.5 Impact17 4.6.1.2.6 Flexibility17 4.6.2 Cable for installation within sub-ducts (previousty installed into the gas pipe)18 4.6.2.1 Tests applicable.18 4.6.2.2 Details of family requirements and test co

21、nditions for high pressure gas pipe cable tests19 4.6.2.2.1 Tensile performance19 4.6.2.2.2 Repeated bending19 4.6.2.2.3 Torsion.20 CLC/TS 50430:2005 - 4 - 4.6.2.2.4 Bend20 4.6.2.2.5 Crush.20 4.6.2.2.6 Impact21 4.6.2.2.7 Temperature cycling21 4.6.2.3 Details of family requirements and test condition

22、s for blowing performance of high pressure gas pipe cables to be installed in sub-ducts 22 4.6.3 Cables for direct installation into the high pressure gas pipe23 4.6.3.1 Tests applicable.23 4.6.3.2 Details of family requirements and test conditions for high pressure gas pipe cables 24 4.6.3.2.1 Tens

23、ile performance24 4.6.3.2.2 Repeated bending24 4.6.3.2.3 Torsion.25 4.6.3.2.4 Bend 25 4.6.3.2.5 Crush.25 4.6.3.2.6 Impact26 4.6.3.2.7 Temperature cycling26 4.7 Examples of sub-ducts and high pressure gas pipe cables 27 4.7.1 Cables for installation in sub-ducts within gas pipes.27 4.7.2 Cables for d

24、irect installation into the high pressure gas pipes 28 4.7.2.1 High pressure gas pipe cables.28 4.8 Examples for installation schemes of cables in high pressure gas pipes (Fiber-in-Gas) 29 4.8.1 Steel gas pipes .29 4.8.2 PE gas pipes30 Annex A (informative) O.F. cables for high pressure gas pipes31

25、- 5 - CLC/TS 50430:2005 1 Scope This document is a family specification that covers gas pipe cables and sub-ducts for installation by blowing and/or pulling / dragging in high pressure gas pipes. Systems built with components covered by this standard are subject to the requirements of sectional spec

26、ifications EN 60794-3 and EN 60794-4 where applicable. Gas pipe cable and sub-duct constructions have to meet the different requirements of the gas- companies and/or associations regarding chemical, environmental, operational interactions and in general maintenance conditions. A table of preferentia

27、l applications, describing gas pipe cable characteristics versus methods of installation is reported in Annex A for high pressure gas pipe cables. Clause 4 describes a blank detail specification for gas pipe cables and sub-ducts for installation by blowing and/or pulling / dragging in/into high pres

28、sure gas pipes. It incorporates some minimum requirements. Detail specifications may be prepared on the basis of this family specification. The parameters specified in this standard may be affected by measurement uncertainty arising either from measurement errors or calibration errors due to lack of

29、 suitable standards. Acceptance criteria should be interpreted with respect to this consideration. The number of fibres tested is representative of the sewer cable and should be agreed between the customer and supplier. 2 Normative references The following referenced documents are indispensable for

30、the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 60068-2-2 Environmental testing (IEC 60068-2-2) EN 60793-1-20 Optical fibres - Part 1-20: Measurement m

31、ethods and test procedures - Fibre geometry (IEC 60793-1-20) EN 60793-1-40 Optical fibres - Part 1-40: Measurement methods and test procedures Attenuation (IEC 60793-1-40) EN 60793-1-44 Optical fibres - Part 1-44: Measurement methods and test procedures - Cut-off wavelength (IEC 60793-1-44) EN 60793

32、-2 Optical fibres - Part 2: Product specifications (IEC 60793-2) EN 60794-1-1 Optical fibre cables - Part 1-1: Generic specification -General (IEC 60794-1-1) EN 60794-1-2 Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures (IEC 60794-1-2) EN 60794-3 Optical f

33、ibre cables - Part 3: Sectional specification - Outdoor cables Duct, buried and aerial cables (IEC 60794-3) EN 60794-3-10 Optical fibre cables - Part 3-11: Detailed specification - Outdoor cables - Duct and directly buried optical telecommunication cables (IEC 60794-3-10) EN 60794-4 2003 Optical fib

34、re cables - Part 3: Sectional specification Aerial optical cables along electrical power lines (IEC 60794-4:2003) CLC/TS 50430:2005 - 6 - EN 60811-1-1 1995 Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - M

35、easurement of thickness and overall dimensions - Tests for determining the mechanical properties (IEC 60811-1-1:1993) EN 60811-5-1 1999 Common test methods for insulating and sheathing materials of electric cables - Part 5: Methods specific to filling compounds. Section one - Drop-point - Separation

36、 of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 C - D.C. resistivity at 23 C and 100 C (IEC 60811-5-1:1990, mod) EN 187105 Single mode optical cable (duct/direct buried installation) HD 402 S2 1984 Standard colours for insulation for

37、 low-frequency cables and wires (IEC 60304:1982) 3 Symbols For the purposes of this document, the following symbols apply: CCcabled fibre cut-off wavelength d nominal outer diameter of the sewer cable DS detail specification T Othreshold tensile load below which no attenuation and/or fibre strain in

38、crease should occur in the tensile performance test T Mthe acceptable amount of short-term tensile load that can be applied to the cable without permanent degradation of the characteristics of the fibres in the tensile performance test T AItemperature cycling test low-temperature limit according to

39、EN 60794-1-2, method Fl T A2temperature cycling test low-temperature limit according to EN 60794-1-2, method Fl T B1temperature cycling test high-temperature limit according to EN 60794-1-2, method Fl T B2temperature cycling test high-temperature limit according to EN 60794-1-2, method Fl t 1tempera

40、ture cycling dwell time n x d a value times cable outer diameter used for bends, mandrels, etc. - 7 - CLC/TS 50430:2005 4 Family specification for gas pipe cables and sub-ducts for installation by blowing and/or pulling/dragging in/into gas pipes (blank detail specification and minimum requirements)

41、 4.1 Construction 4.1.1 General In addition to the constructional requirements of sectional specifications EN 60794-3 and EN 60794-4, where applicable, the following considerations apply to the gas pipe cables and/or sub-ducts. The gas pipe cables and/or sub-ducts shall be designed and manufactured

42、for an expected operating lifetime of at least 10 years. It shall be possible to install or remove the cable in or from the gas pipe throughout the operational lifetime. The materials in the gas pipe cable and/or as well as accessories including fixing elements i.e. I/O-ports and sub-ducts shall not

43、 present a health hazard within its intended use. 4.1.2 Sub-ducts In case of use, the sub-duct with outer nominal diameters ranging from xx mm to yy mm shall be able to resist pressure differences needed for installation by blowing and able to withstand the gas pressure within the gas pipe. They sha

44、ll be circular and the outer and inner surfaces a low coefficient of friction. The material shall withstand all possible chemical attacks by the natural gas itself, as for instance the PE 100. Inner- and outer-diameter and overall minimum wall thickness shall be specified. 4.1.3 Gas pipe cables A ga

45、s pipe cable in accordance to this specification should be suitable for installation in high pressure gas pipes by the following installation methods, also applicable the access gas pipe network: blowing and /or pulling into a sub-duct, previously installed into the high pressure gas pipe between tw

46、o I/O - ports; direct installation into the gas pipe in between two adjacent I/O-ports. The attenuation of the installed cable at the operational wavelength(s) shall not exceed values agreed between the customer and supplier. There shall be no fibre splice in a delivery length unless otherwise agree

47、d by the customer and supplier. It shall be possible to identify each individual fibre throughout the length of the sewer cable. CLC/TS 50430:2005 - 8 - 4.2 Product descriptions 4.2.1 Gas pipe cables description 4.2.1.1 Cable for installation within sub-ducts (previously installed into the gas pipe

48、in between two adjacent I/O-ports) Fibre count: up to 288. Such gas pipe cable has to be blown or pulled into the sub-duct described in 4.2.2. (1) Prepared by (2) Document No.: Issue: Date: (3) Available from: (4) Generic specifications: EN 60794-1-1 and EN 60794-1-2Sectional specification: EN 60794

49、-3 (5) Additional references: Construction - Tube filled Additional armouring - Metallic armouring Outer sheath Marking identification - Customer requirement - Identification of manufacturer Additional remarks (8) Application information: Maximum outer diameter (d) Rated maximum tensile load Minimum bending radius for no-load bending Minimum bending radius for rated-load bending Temperature range - Transport and storage - Installation - Operation Manufacturing len