1、ICS 91.100.10Methods of test for mortar for masonryPart 17: Determination of water-soluble chloride content of fresh mortar(includes Amendment A1 : 2004)English version of DIN EN 1015-17 : 2000 + A1 : 2004Prfverfahren fr Mrtel fr Mauerwerk Teil 17: Bestimmung des Gehalts an wasserlslichem Chlorid vo
2、nFrischmrtel (enthlt nderung A1 : 2004)A comma is used as the decimal marker.National forewordThis standard has been prepared by CEN/TC 125 Masonry (Secretariat: United Kingdom).The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Buildingand Civil Engineering St
3、andards Committee), Technical Committee 06.01.00 Mauerwerksbau.This European Standard is part of a series of standards specifying methods used to check compliance ofmortar with the requirements specified in the relevant product standard.AmendmentsThis standard differs from the September 2000 edition
4、 in that it has been completely revised.Previous editionDIN EN 1015-17: 2000-09.DEUTSCHE NORM January 2005DIN EN 1015-17 No part of this standard may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung e.V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusiv
5、e right of sale for German Standards (DIN-Normen).SupersedesSeptember 2000 edition.English price group 6www.din.dewww.beuth.de9626850Continued overleaf.Document comprises 10 pages.05.05English versionICS 91.100.10 Supersedes EN 1015-17 : 2000.Methods of test for mortar for masonryPart 17: Determinat
6、ion of water-soluble chloride content of fresh mortar(includes Amendment A1 : 2004) 2004. CEN All rights of exploitation in any form and by any meansreserved worldwide for CEN national members.Ref. No. EN 1015-17 : 2000 + A1 : 2004 EPrfverfahren fr Mrtel fr Mauer-werk Teil 17: Bestimmung des Ge-halt
7、s an wasserlslichem Chlorid vonFrischmrtel (enthlt nderungA1 : 2004)This European Standard was approved by CEN on 2000-02-25 and AmendmentA1 on 2004-08-06.CEN members are bound to comply with the CEN/CENELEC Internal Regulationswhich stipulate the conditions for giving this European Standard the sta
8、tus of anational standard without any alteration.Up-to-date lists and bibliographical references concerning such national stand-ards may be obtained on application to the Management Centre or to anyCEN member.The European Standards exist in three official versions (English, French, German).A version
9、 in any other language made by translation under the responsibility of aCEN member into its own language and notified to the Management Centre hasthe same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, theCzech Republic, Denmark, Estonia, F
10、inland, France, Germany, Greece, Hungary,Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands,Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, andthe United Kingdom.Management Centre: rue de Stassart 36, B-1050 BrusselsEuropean Committee for Standar
11、dizationComit Europen de NormalisationEuropisches Komitee fr NormungMthodes dessai des mortiers pourmaonnerie Partie 17: Dterminationde la teneur en chlorure soluble desmortiers frais (amendement A1 : 2004inclus)EN 1015-17October 2004+ A1March 2000Page 2EN 1015-17 : 2000 + A1 : 2004Foreword to EN 10
12、15-17 : 2000This European Standard has been prepared by Technical Committee CEN/TC 125 Masonry, the Secretariatof which is held by BSI.This European Standard shall be given the status of a national standard, either by publication of an identicaltext or by endorsement, and conflicting national standa
13、rds withdrawn, by September 2000 at the latest.In accordance with the CEN/CENELEC Internal Regulations, the national standards organizations of the follow-ing countries are bound to implement this European Standard:Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland,
14、 Ireland, Italy, Luxem-bourg, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.This European Standard calls for the use of substances and procedures that may be injurious to healthif adequate precautions are not taken. It refers only to the technical suitability a
15、nd does not absolve theuser from legal obligations relating to health and safety at any stage.Foreword to EN 1015-17 : 2001/A1 : 2004This amendment to EN 1015-17 : 2000 has been prepared by Technical Committee CEN/TC 125 Masonry, theSecretariat of which is held by BSI.This amendment shall be given t
16、he status of a national standard, either by publication of an identical text or byendorsement, by April 2005 at the latest, and conflicting national standards shall be withdrawn by July 2006at the latest.In accordance with the CEN/CENELEC Internal Regulations, the national standards organizations of
17、 the follow-ing countries are bound to implement this European Standard:Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal,Slovakia, Sloveni
18、a, Spain, Sweden, Switzerland, and the United Kingdom.ContentsPageForeword to EN 1015-17 : 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Foreword to EN 1015-17 : 2000/A1 : 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Scope . . . . . . . . . .
19、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Normative references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20、 . . . . . . . . . . . 34 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Apparatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Reagents . . . . . . . . . . . . . .
21、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Sampling and sample preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
22、9 Calculation and expression of results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 810 Test report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Page 3EN 1015-17 : 2000 + A1 : 2004Page 4EN 1015-17 : 2000 + A1 : 2004Page 5EN 1015-17 : 2000 + A1 : 2004Page 6EN 1015-17 : 2000 + A1 : 2004Page 7EN 1015-17 : 2000 + A1 : 2004Page 8EN 1015-17 : 2000 + A1 : 2004Page 9EN 1015-17 : 2000 + A1 : 2004