1、October 2007DEUTSCHE NORM English price group 14No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.060.40!$II“1383804w
2、ww.din.deDDIN EN 13063-1Chimneys System chimneys with clay/ceramic flue liners Part 1: Requirements and test methods for sootfire resistance (includesAmendment A1:2007)English version of DIN EN 13063-1:2007-10Abgasanlagen System-Abgasanlagen mit Keramik-Innenrohren Teil 1: Anforderungen und Prfungen
3、 fr Rubrandbestndigkeit (enthlt nderungA1:2007)Englische Fassung DIN EN 13063-1:2007-10SupersedesDIN EN 13063-1:2006-03www.beuth.deDocument comprises 40 pages DIN EN 13063-1:2007-10 2 Start of validity This standard is due to be valid from 01 April 2008. It should be noted that, in Germany, CE confo
4、rmity marking of construction products will be permitted once this standard has been listed in the Bundesanzeiger (German Federal Law Gazette). National foreword This standard has been prepared by CEN/TC 166 “Chimneys” (Secretariat: UNI, Italy). The responsible German body involved in its preparatio
5、n was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Technical Committee NA 005-11-36 AA Abgasanlagen aus Keramik und Beton (SpA CEN/TC 166/SC1 und WG 3). Amendments This standard differs from DIN EN 13063-1:2006-03 as follows: a) Clause 5 has been editorially rev
6、ised. b) Fire resistance has been included in Table ZA.1 Previous editions DIN 18147-1: 1982-11, 1987-02 DIN 18147-5: 1982-11, 1983-03, 1987-02 DIN EN 13063-1: 2006-03 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13063-1:2005+A1 July 2007 ICS 91.060.40 Supersedes EN 13063-1:2005 English Vers
7、ion Chimneys - System chimneys with clay/ceramic flue liners - Part 1: Requirements and test methods for sootfire resistance Conduits de fumes - Conduits-systmes avec conduit intrieur en terre cuite/cramique - Partie 1: Exigences et mthodes dessai relatives la dtermination de la rsistance au feu de
8、chemine Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 1: Anforderungen und Prfungen fr Rubrandbestndigkeit This European Standard was approved by CEN on 2 September 2005 and includes Amendment 1 approved by CEN on 14 June 2007. CEN members are bound to comply with the CEN/CENELEC
9、 Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CE
10、N member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN
11、 members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swed
12、en, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members
13、. Ref. No. EN 13063-1:2005+A1:2007: EEN 13063-1:2005+A1:2007 (E) 2 Contents Foreword4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Shapes, dimensions and tolerances8 4.1 Flue liners .8 4.2 Insulation 8 4.3 Outer wall elements.9 4.4 Cleaning and inspection doors 9 5 Material requir
14、ements .9 5.1 General requirements for components .9 5.2 Safety in use.11 5.3 Hygiene, health and environment 12 5.4 Cleaning and inspection doors 12 5.5 Freeze/thaw resistance .13 5.6 Temperature classes .13 5.7 Pressure classes13 6 Replacement of single components of the system chimney 13 6.1 Chan
15、ge of flue liner .13 6.2 Change of opening sections.13 6.3 Change of insulation .14 6.4 Change of jointing materials for inner liners 14 6.5 Change of outer wall elements.14 6.6 Change of cleaning and inspection doors 14 7 Designation 14 8 Product information.15 9 Marking and labelling 16 10 Evaluat
16、ion of conformity.16 10.1 General16 10.2 Components.16 10.3 Initial type testing of soot fire resistant system chimneys .17 10.4 Exchange of components .17 10.5 Factory production control.18 PageEN 13063-1:2005+A1:2007 (E) 3 Annex A (normative) Test methods19 Annex B (normative) Stainless steel oute
17、r walls 25 Annex C (normative) Thermal resistance of the system chimney 26 Annex D (normative) Sampling procedures for an AQL of 10 % and inspection level S227 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Product Directive .31 Bibliography
18、38 EN 13063-1:2005+A1:2007 (E) 4 Foreword This document (EN 13063-1:2005+A1:2007) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This document shall be given the status of a national standard, either by publication of an identical text or by
19、endorsement, at the latest by January 2008 and conflicting national standards shall be withdrawn at the latest by April 2009. This document includes Amendment 1 approved by CEN on 2007-06-14. This document supersedes EN 13063-1:2005. The start and finish of text introduced or altered by amendment is
20、 indicated in the text by tags ! “. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA which
21、is an integral part of this document. This standard is part 1 of a series of standards for system chimneys with clay/ceramic flue liners. Part 2 is for system chimneys working under wet conditions and part 3 is for system air flue chimneys. According to the CEN/CENELEC Internal Regulations, the nati
22、onal standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
23、Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 13063-1:2005+A1:2007 (E) 5 1 Scope This European Standard specifies the requirements and test methods for multiwall soot fire resistant system chimneys, working under dry conditions, with corrosion resis
24、tance 3, with negative pressure (see EN 1443) in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this standard. This standard does not apply to structurally independent (free standing or self-supporting) sys
25、tem chimneys. A soot fire resistant system chimney has the following items where appropriate: clay/ceramic flue liners; Insulation layer; outer walls; mortar for jointing flue liners; mortar for jointing outer walls; terminal; chimney base; cladding; opening section; cleaning and inspection door; di
26、stance piece; reinforcement. The soot fire resistant chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole chimney. 2 Normative references The following referenced documents are indispensable for t
27、he application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 998-2:2003, Specification for mortar for masonry Part 2: Masonry mortar EN 1366-8, Fire resistance tests
28、 for service installations Part 8: Smoke extraction ducts EN 1443:2003, Chimneys General requirements EN 1457:1999, Chimneys Clay/ceramic flue liners Requirements and test methods !EN 1806:2006“, Chimneys Clay/ceramic flue blocks for single wall chimneys Requirements and test methods EN 13063-1:2005
29、+A1:2007 (E) 6 EN 1859, Chimneys Metal chimneys Test methods EN 12446:2003, Chimneys Components Concrete outer wall elements EN 13069:2005, Chimneys Clay/ceramic outer walls for system chimneys Requirements and test methods EN 13162:2001, Thermal insulation products for buildings Factory made minera
30、l wool (MW) products Specification EN 13216-1:2004, Chimneys Test methods for system chimneys Part 1: General test methods EN 13384-1, Chimneys - Thermal and fluid dynamic calculation methods Part 1: Chimneys serving one appliance !EN 13501-2, Fire classification of construction products and buildin
31、g elements Part 2: Classification using data from fire resistance tests, excluding ventilation services“ EN 14297:2004, Chimneys Freeze-thaw resistance test method for chimney products EN ISO 1182, Reaction to fire tests for building products Non-combustibility test (ISO 1182:2002) ISO 2859-1, Sampl
32、ing procedures for inspection by attributes Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1443:2003 and EN 13216-1:2004 and the following apply. 3.
33、1 soot fire resistant multiwall system chimney multiwall construction, consisting mainly of an outer wall, an insulation layer and a sootfire resistant inner clay/ceramic flue liner. The combination of these components forms a sootfire resistant system chimney (see Figure 1) EN 13063-1:2005+A1:2007
34、(E) 7 Key 1 Inner liner 2 !Insulation layer (insulation or air gap)“ 3 Outer wall 4 Cavities for back ventilation 5 Cavities for structural reinforcement Figure 1 Construction of a soot fire resistant system chimney 3.2 chimney base section of the system chimney, situated at the bottom, which compri
35、ses an inspection opening with door 3.3 reinforced outer wall outer wall having reinforcement to assist handling (not for structural stability) 3.4 structural reinforcement additional strengthening for structural stability (in the outer wall) 3.5 freeze-thaw-resistance ability of the product to resi
36、st the effects of freezing and thawing 3.6 opening section flue liner which has an opening for cleaning and inspection or connection for another flue (junction) 3.7 cleaning and inspection door door in outer wall element to allow cleaning and inspection of the chimney. There are two types of cleanin
37、g and inspection doors (see Figure 2): - a cleaning and inspection door combined with an opening section with inner door - a cleaning and inspection door combined with an opening section without inner door EN 13063-1:2005+A1:2007 (E) 8 Key 1 Cleaning and inspection door 2 Inner door of the opening s
38、ection 3 Opening section 4 Insulation layer 5 Outer wall Figure 2 - Examples of cleaning and inspection doors and the opening sections 3.8 distance piece spacer to keep distance between outer wall element and insulation or inner liner 4 Shapes, dimensions and tolerances 4.1 Flue liners 4.1.1 General
39、 Flue liners shall meet the requirements on size and tolerance of dimensions given in 7.1, 7.2, 7.3, 7.4, 7.5, 7.6 and 7.7 of EN 1457:1999. 4.1.2 External dimensions of flue liner When tested in accordance with A.2.6, the external dimensions of flue liners measured on any cross section shall not dev
40、iate more than 3 % of the manufacturers stated nominal external dimensions. 4.2 Insulation The insulation layer shall meet the requirements on tolerance of dimensions given in 4.2.2 (length and width) and 4.2.3 (thickness class T3) of EN 13162:2001. EN 13063-1:2005+A1:2007 (E) 9 4.3 Outer wall eleme
41、nts Outer wall elements shall fulfil the requirements on shapes and tolerances on dimensions given in: concrete outer wall elements: EN 12446:2003, Clause 7 clay/ceramic outer walls: EN 13069:2005, Clause 6 metal outer walls: Annex B 4.4 Cleaning and inspection doors Dimensions and tolerances shall
42、be declared by the manufacturer. 5 Material requirements 5.1 General requirements for components 5.1.1 General All components of soot fire resistant system chimneys shall be non combustible in accordance to EN ISO 1182. 5.1.2 Clay/ceramic flue liners Flue liners shall meet the requirements of EN 145
43、7 clauses: 8.1 Straight flue liners (proof load); 8.3 Minimum load for inspection opening sections (proof load); 9.1 Initial test (gas tightness, thermal shock resistance and resistance to fire for straight flue liners); 9.2 Final gas tightness after thermal shock testing; 10 Acid resistance; 11 Wat
44、er absorption and bulk density; 12 Sweeping resistance. 5.1.3 Maximum compressive strength for opening sections When tested as described in A.2.3, components shall withstand a load of at least five times the manufacturers declared design load. F = ( H G)/100 (1) where F = minimum load (kN); = safety
45、 factor = 5; H = height of chimney (m); EN 13063-1:2005+A1:2007 (E) 10 G = Weight per metre (kg/m). NOTE The limiting factor of the maximum height of system chimneys is the compressive strength of the opening section. 5.1.4 Jointing material for flue liners 5.1.4.1 Density The density of jointing ma
46、terial shall not vary more than 10 % of the manufacturer declared value when tested in accordance to A.2.2.2. 5.1.4.2 Compressive strength The compressive strength shall be at least 10 N/mmwhen tested according to A.2.2.3. 5.1.5 Insulation 5.1.5.1 General The insulation shall be to the manufacturers
47、 specifications and shall be prefabricated and have an independent permanent shape before and after being exposed to heat in operating conditions (e.g. blocks or bonded loose material). 5.1.5.2 Density The manufacturer shall declare the density of the insulation and this shall not vary by more than
48、10 % of the declared value and shall be tested according to !EN 1806:2006“, 17.15. 5.1.5.3 Durability under soot fire conditions When tested in accordance to A.2.1 the change in the outside surface temperature of the test sample after the fourth cycle of heating shall not exceed 10 % of the maximum
49、outside surface temperature of the sample of the first cycle. 5.1.6 Outer wall elements The outer wall elements shall fulfil EN 12446 for concrete outer wall elements, EN 13069 for clay/ceramic outer wall or Annex B for stainless steel metal outer walls. 5.1.7 Jointing material for outer wall elements Jointing materials used for jointing outer walls, where supplied with the system chimney, shall comply with the system chimney manufacturers declared s