1、December 2016 English price group 27No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 13.220.50!%Z“2596155www.din.deD
2、IN EN 13501-2Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services;English version EN 135012:2016,English translation of DIN EN 13501-2:2016-12Klassifizierung von Bauprodukten und Bauarten zu ih
3、rem Brandverhalten Teil 2: Klassifizierung mit den Ergebnissen aus den Feuerwiderstandsprfungen, mit Ausnahme von Lftungsanlagen;Englische Fassung EN 135012:2016,Englische bersetzung von DIN EN 13501-2:2016-12Classement au feu des produits et lments de construction Partie 2: Classement partir des do
4、nnes dessais de rsistance au feu lexclusion des produits utiliss dans les systmes de ventilation;Version anglaise EN 135012:2016,Traduction anglaise de DIN EN 13501-2:2016-12SupersedesDIN EN 135012:201002www.beuth.deDocument comprises 81 pagesDTranslation by DIN-Sprachendienst.In case of doubt, the
5、German-language original shall be considered authoritative.12.16 DIN EN 13501-2:2016-12 2 A comma is used as the decimal marker. National foreword This document (EN 13501-2:2016) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings” (Secretariat: BSI, United Kingdom). The re
6、sponsible German body involved in its preparation was DIN-Normenausschuss Bauwesen (DIN Standards Committee Building and Civil Engineering), Working Committee NA 005-52-02 AA Brandverhalten von Baustoffen und Bauteilen Bauteile. Amendments This standard differs from DIN EN 13501-2:2010-02 as follows
7、: a) general editorial amendments have been made; b) normative references have been updated. Previous editions DIN EN 13501-2: 2003-12, 2008-01, 2010-02 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13501-2 June 2016 ICS 13.220.50 Supersedes EN 13501-2:2007+A1:2009English Version Fire classif
8、ication of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services Classement au feu des produits et lments de construction - Partie 2: Classement partir des donnes dessais de rsistance au feu lexclusion des produits
9、utiliss dans les systmes de ventilation Klassifizierung von Bauprodukten und Bauarten zu ihrem Brandverhalten - Teil 2: Klassifizierung mit den Ergebnissen aus den Feuerwiderstandsprfungen, mit Ausnahme von Lftungsanlagen This European Standard was approved by CEN on 23 April 2016. CEN members are b
10、ound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
11、 CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centr
12、e has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania
13、, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000
14、Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13501-2:2016 EContents Page European foreword . 5 Introduction 6 1 Scope 7 2 Normative references 8 3 Terms and definitions 11 4 Fire scenarios 15 4.1 General . 15 4.2 T
15、he standard temperature/time curve (post flash-over fire) . 15 4.3 The slow heating curve (smouldering fire) 16 4.4 The semi-natural fire 16 4.5 The external fire exposure curve . 17 4.6 Constant temperature attack . 17 5 Resistance to fire performance characteristics 17 5.1 General . 17 5.2 Perform
16、ance characteristics 17 5.2.1 R - Loadbearing capacity . 17 5.2.2 E - Integrity . 18 5.2.3 I - Thermal insulation . 19 5.2.4 W - Radiation . 20 5.2.5 M - Mechanical action . 21 5.2.6 C - Self-closing 21 5.2.7 S - Smoke leakage . 21 5.2.8 G - Soot fire resistance 22 5.2.9 K - Fire protection ability
17、22 6 Declaration of fire resistance performance 23 6.1 Classification periods . 23 6.2 Designatory letters 23 6.3 Declaration of performance . 23 6.4 Combinations of classes . 23 6.5 Particular classifications . 24 6.5.1 Doors and shutters 24 6.5.2 Conveyor systems and their closures . 24 6.6 Additi
18、onal performance parameters 24 6.6.1 Optional performance parameters 24 6.6.2 Expansion of performance parameters . 24 6.6.3 Particular performance parameters . 25 6.7 Presentation of classification 25 6.8 Declaration of fire resistance classes in product specifications . 25 7 Classification procedu
19、re for fire resistance . 26 7.1 General . 26 7.1.1 Procedure 26 7.1.2 General rules for deducing the number of standard temperature/time fire resistance tests 27 DIN EN 13501-2:2016-12 EN 13501-2:2016 (E) 2 7.1.3 Field of application 29 7.2 Classification of loadbearing elements without a fire separ
20、ating function 29 7.2.1 General . 29 7.2.2 Classification of loadbearing walls without separating function . 29 7.2.3 Classification of loadbearing floors and roofs without fire separating function 30 7.2.4 Classification of beams . 31 7.2.5 Classification of columns . 32 7.2.6 Classification of bal
21、conies, walkways and stairs 33 7.3 Classification of loadbearing elements with fire separating function 34 7.3.1 General . 34 7.3.2 Classification of loadbearing walls with fire separating function 34 7.3.3 Classification of loadbearing floors and roofs with fire separating function . 36 7.3.4 Class
22、ification of raised floors . 37 7.4 Products and systems for protecting elements or parts of works 38 7.4.1 General . 38 7.4.2 Tests to be carried out 39 7.4.3 Test methods 40 7.4.4 Performance criteria 40 7.4.5 Classes 40 7.4.6 Classification of protected structural members . 40 7.5 Classification
23、of non-loadbearing elements . 44 7.5.1 General . 44 7.5.2 Partitions . 44 7.5.3 Classification of facades (curtain walling) and external walls (including glazed elements). 46 7.5.4 Classification of ceilings with independent fire resistance 47 7.5.5 Classification of fire doors and shutters includin
24、g their closing devices 49 7.5.6 Classification of smoke control doors . 51 7.5.7 Classification of closure and conveyor system assemblies . 52 7.5.8 Classification of penetration seals . 54 7.5.9 Classification of linear joint seals . 55 7.5.10 Classification of service ducts and shafts 57 7.5.11 C
25、lassification of chimneys . 59 7.6 Classification of wall and ceiling coverings for fire protection ability . 60 7.6.1 General . 60 7.6.2 Test method 61 7.6.3 Tests to be carried out 61 7.6.4 Performance criteria for fire protection ability 61 7.6.5 Classes 62 Annex A (normative) Classification repo
26、rt 63 A.1 General . 63 A.2 Content and format 63 A.3 Classification report format . 64 Annex B (informative) Presentation of characterization data and their field of application for products and systems for protecting elements or parts of work 68 B.1 General . 68 B.2 Characterization data for protec
27、tive vertical membranes . 68 B.3 Characterization data for applied protection to concrete members . 69 DIN EN 13501-2:2016-12 EN 13501-2:2016 (E)3 B.4 Characterization data for applied protection to steelwork 70 B.5 Characterization data for applied protection to concrete/profiled sheet steel compos
28、ite members 72 B.6 Characterization data for applied protection to concrete filled hollow steel columns 73 B.7 Characterization data for applied protection to timber members 74 Bibliography . 79 DIN EN 13501-2:2016-12 EN 13501-2:2016 (E) 4 European foreword This document (EN 13501-2:2016) has been p
29、repared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This document supersedes EN 13501-2:2007+A1:2009. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at t
30、he latest by December 2016, and conflicting national standards shall be withdrawn at the latest by December 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any
31、 or all such patent rights. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. CEN, CENELEC and EOTA committees preparing technical specifications which contain performance requirements against resistance to fire
32、tests should make reference to the resistance to fire classification given in this European Standard and not refer directly to any specific fire test method. Changes have been made in this revision to bring it in line with the relevant current EC Decisions on fire resistance classification, and expe
33、rience in use in the first edition. EN 13501 Fire classification of construction products and building elements consists of the following Parts: Part 1: Classification using data from reaction to fire tests Part 2: Classification using data from fire resistance tests, excluding ventilation services
34、Part 3: Classification using data from fire resistance tests on components of normal building service installations: fire resisting ducts and fire dampers Part 4: Classification using data from fire resistance tests on components of smoke control systems Part 5: Classification using data from extern
35、al fire exposure to roof tests Part 6: Classification using data from reaction to fire tests on electric cables According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria
36、, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey
37、 and the United Kingdom. DIN EN 13501-2:2016-12 EN 13501-2:2016 (E)5 Introduction The aim of this European Standard is to define a harmonised procedure for the classification for resistance to fire of construction products and building elements. This classification is based on the test procedures li
38、sted in Clause 2 and the relevant field of application procedures. This European Standard is prepared in support of the second basic requirement, in the EC Construction Products Regulation ( 305/2011) and is detailed in the Interpretative Document number 2 (ID2): Safety in case of fire (OJC62 Vol 37
39、). The Interpretative Document and the Commission Decision of 2 May 2000 specify performance and classes regarding fire resistance. These classes are identified by designation letters, each of which refers to an important characteristic of fire resistance behaviour. This European Standard provides f
40、or a common understanding for these requirements. It interprets the functional requirements for the different groups of building elements and explains the method for deriving their classification on the basis of test results and/or extended application results for individual elements. NOTE Test repo
41、rts constitute the basis for extended application reports as explained in EN 15725. DIN EN 13501-2:2016-12 EN 13501-2:2016 (E) 6 1 Scope This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage
42、tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard. This European Standard deals with: a) loadbearing elements without a fire separating functi
43、on: walls; floors; roofs; beams; columns; balconies; walkways; stairs. b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures: walls; floors; roofs; raised floors. c) products and systems for protecting elements or parts of the works: ceilings with no
44、 independent fire resistance; fire protective coatings, claddings and screens; d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures: partitions; facades (curtain walls) and external walls; ceilings with independent fire resistance; raised floors; fire doors a
45、nd shutters and their closing devices; DIN EN 13501-2:2016-12 EN 13501-2:2016 (E)7 smoke control doors; conveyor systems and their closures; penetration seals; linear joint seals; service ducts and shafts; chimneys. e) wall and ceiling coverings with fire protection ability. f) lift landing doors wh
46、ich are tested according to EN 81-58 are excluded from this European Standard. Lift landing doors which are tested in accordance with EN 1634-1, are classified in accordance with 7.5.5. Relevant test methods which have been prepared for these elements are listed in Clauses 2 and 7. 2 Normative refer
47、ences The following documents in whole or in part are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-2, Fire resistance tests - Part 2: Alternative and additional procedures EN 1364-1:2015, Fire resistance tests for non-loadbearing elements - Part 1: Walls EN 1364-2:1999, Fire resistance tests for non-loadbearing elements