1、October 2013 Translation by DIN-Sprachendienst.English price group 10No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 91.100.60!%)LJ“2064139www.din.deDDIN EN 14063-2Thermal insulation products for buildings In-situ formed expanded clay lightweight aggregate products Part 2: Specification for the installed products;English version EN 14063-2:2013,English translation of DIN EN 14063-2:2013-10Wrmedmmstoffe fr Gebude
3、 An der Verwendungsstelle hergestellte Wrmedmmung ausBlhton-Leichtzuschlagsstoffen (LWA) Teil 2: Spezifikation fr die eingebauten Produkte;Englische Fassung EN 14063-2:2013,Englische bersetzung von DIN EN 14063-2:2013-10Produits isolants thermiques pour le btiment Produits base de granulats lgers da
4、rgile expanse forms en place Partie 2: Spcifications relatives aux produits installs;Version anglaise EN 14063-2:2013,Traduction anglaise de DIN EN 14063-2:2013-10www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 15 pages 09.13 DIN EN 140
5、63-2:2013-10 2 A comma is used as the decimal marker. National foreword This document (EN 14063-2:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products” (Secretariat: DIN, Germany) The responsible German body involved in its preparation was the Normenaus
6、schuss Bauwesen (Building and Civil Engineering Standards Committee), Working Committee NA 005-56-60 AA Wrmedmmstoffe. This document is part of a package of interrelated standards for the specification of factory made thermal insulation products. EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN
7、14063-2 July 2013 ICS 91.100.60 English Version Thermal insulation products for buildings - In-situ formed expanded clay lightweight aggregate products - Part 2: Specification for the installed products Produits isolants thermiques pour le btiment - Produits base de granulats lgers dargile expanse f
8、orms en place - Partie 2: Spcifications relatives aux produits installs Wrmedmmstoffe fr Gebude - An der Verwendungsstelle hergestellte Wrmedmmung aus Blhton-Leichtzuschlagsstoffen (LWA) - Teil 2: Spezifikation fr die eingebauten Produkte This European Standard was approved by CEN on 23 May 2013. CE
9、N members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on app
10、lication to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC M
11、anagement Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, La
12、tvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1
13、000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14063-2:2013: EEN 14063-2:2013 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms, definitions, symbols, units and abbreviated terms .4 3.1 Te
14、rms and definitions .4 3.2 Symbols and units .5 3.3 Abbreviated terms .5 4 Requirements .5 4.1 General 5 4.2 Guidelines for installation .5 4.3 Declared installed thermal resistance, RD.6 4.4 Declared installed insulation thickness, dm6 4.5 Declared moisture content .6 4.6 Settlement .6 4.7 Compacti
15、on 6 5 In-situ measurements and calculations 7 5.1 Calculation of the declared mean installed insulation thickness .7 5.2 Calculation of declared installed thermal resistance, RD7 6 Installers declaration 7 Annex A (normative) Method for the determination of density and degree of compaction of the i
16、nstalled product 8 A.1 Principle 8 A.2 Apparatus .8 A.3 Test specimens, samples .9 A.4 Procedure .9 A.4.1 Test conditions 9 A.4.2 Test procedure .9 A.5 Calculation and expression of results .9 A.6 Precision 10 A.7 Test report . 11 Annex B (normative) Installation guidelines . 12 B.1 Suitability of t
17、he building to receive the insulation product 12 B.2 Tests made by the installer when preparing the product on site 12 B.3 Installation procedure 12 B.4 Installers declaration . 12 Bibliography . 13 DIN EN 14063-2:2013-10 EN 14063-2:2013 (E) 3 Foreword This document (EN 14063-2:2013) has been prepar
18、ed by Technical Committee CEN/TC 88 “Thermal insulating materials and products“, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2014, and conflict
19、ing national standards shall be withdrawn at the latest by January 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This European
20、 standard consists of two parts. The first part is the harmonised part satisfying the mandate and the CPD. It is the basis for the CE marking covering the products, which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installed products.
21、 Both parts need to be used for the application of the insulation products in the end-use applications covered by EN 14063. Part 1 of this European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports the essential re
22、quirements of EU Directives. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1. Attention is drawn to the need to take into account any complementary member state rules (e.g. installation rules) which together with this European Standard ensures the
23、 fitness for purpose of the installed product. This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose, bound expanded polystyrene and expanded polystyrene in-situ formed insulation products used in
24、 buildings, but this standard can be used in other areas where appropriate. The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. According to the CEN/CENELE
25、C Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Icel
26、and, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 14063-2:2013-10 EN 14063-2:2013 (E) 4 1 Scope This European Standard specifies the requirements for loose-f
27、ill expanded clay lightweight aggregate (LWA) products installed in roofs, ceilings, floors and ground floors. This Part 2 is a specification for the installed product. Part 2 of this European Standard describes, when taken together with Part 1, the product characteristics that are linked to the ess
28、ential requirements of the EU Construction Products Directive. Part 2 also specifies the checks and tests to be used for the declarations made by the installer of the product. Part 2 of this European Standard does not specify the required level of a given property to be achieved by a product to demo
29、nstrate fitness for purpose in a particular application. The levels required for a given application are to be found in national regulations or non conflicting standards. This European Standard does not cover factory made expanded clay lightweight aggregate products or in-situ products intended to b
30、e used for the insulation of building equipment and industrial installations. This European Standard does not specify performance requirements for airborne sound insulation and for acoustic absorption applications. 2 Normative references The following documents, in whole or in part, are normatively
31、referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 823:2013, Thermal insulating products for building applications De
32、termination of thickness EN 1097-3, Tests for mechanical and physical properties of aggregates Part 3: Determination of loose bulk density and voids EN 1097-5, Tests for mechanical and physical properties of aggregates Part 5: Determination of the water content by drying in a ventilated oven EN 1406
33、3-1, Thermal insulation products for buildings In-situ formed expanded clay lightweight aggregate products Part 1: Specification for the loose-fill products before installation EN ISO 9229:2007, Thermal insulation Vocabulary (ISO 9229:2007) 3 Terms, definitions, symbols, units and abbreviated terms
34、3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 9229:2007 and the following apply. 3.1.1 expanded clay lightweight aggregate insulation material or product composed of lightweight granular material having a cellular structure formed by expanding
35、 clay minerals by heat DIN EN 14063-2:2013-10 EN 14063-2:2013 (E) 5 3.1.2 design insulation thickness insulation thickness after compaction as specified by the designer 3.1.3 declared installed insulation thickness insulation thickness as installed by the installer including compaction if prescribed
36、 3.1.4 compaction mechanical compression (e.g. by vibrator) of the installed insulation layer, expressed as a percentage of the initially untreated layer thickness SOURCE: EN 14063-1:2004 3.1.5 settlement decrease of installed insulation thickness with time, expressed as a percentage of the initial
37、installed thickness (after compaction if prescribed) 3.2 Symbols and units dmmean insulation thickness m dm,amean installed insulation thickness after compaction m dm,bmean installed insulation thickness before compaction m RDinstalled declared thermal resistance mK/W Ddeclared thermal conductivity
38、W/mK Cpdegree of compaction % 3.3 Abbreviated terms LWA Lightweight Aggregate 4 Requirements 4.1 General The installer shall use an insulation product that complies with EN 14063-1. The installer shall inspect the building in accordance with manufacturers guidelines in order to determine whether it
39、is suitable for application of the product. NOTE National regulations may also apply. 4.2 Guidelines for installation National Practice, National Standards, National Regulations or Local rules may exist, for the installation of the product, In the absence of National Regulations, National Standards
40、or any local rules, the manufacturers technical information shall be followed together with the procedure given in Annex B. DIN EN 14063-2:2013-10 EN 14063-2:2013 (E) 6 4.3 Declared installed thermal resistance, RDThe thermal resistance, RD,shall be assessed by measurement of the declared installed
41、insulation thickness according to 5.1 combined with the declared thermal conductivity, D. NOTE 1 For calculating the thermal resistance of complete building elements involving the use of these products the procedures given in EN ISO 6946 can be used. NOTE 2 EN ISO 10456 describes how the design ther
42、mal conductivity is calculated from the declared thermal conductivity. 4.4 Declared installed insulation thickness, dmThe mean value of the installed thickness, dm,shall be not less than the specified thickness prescribed by the designer. No individual value shall be less than 80 % of the specified
43、value. Installed insulation thickness is measured according to 5.1. 4.5 Declared moisture content When required the moisture content shall be measured in accordance with EN 1097-5 and expressed in % by mass. NOTE The declaration of moisture content is only needed if the products are to be used in co
44、ntact with wooden materials, e.g. between rafters and wooden beams. 4.6 Settlement NOTE The settlement of expanded clay lightweight aggregate products is negligible and therefore no method of measurement has been specified. 4.7 Compaction The installer shall ensure that the degree of compaction spec
45、ified by the client or designer is obtained. The degree of compaction in percent (Cp) shall be calculated using Formula (1): Cp= 100 *(dm,b - dm,a) / dm,b (1) where dm,bis the mean installed insulation thickness before compaction, m dm,ais the mean installed insulation thickness after compaction, m
46、In case of dispute determination of density and degree of compaction of the installed product shall be assessed by the method given in Annex A. The mean installed insulation thickness is calculated as described in 5.1. NOTE The typical degree of compaction is (5-15) % for rounded aggregates and coul
47、d be more for other types of shapes DIN EN 14063-2:2013-10 EN 14063-2:2013 (E) 7 5 In-situ measurements and calculations 5.1 Calculation of the declared mean installed insulation thickness The measured mean installed insulation thickness dm,a, after compaction if prescribed, shall not be less than t
48、he design insulation thickness. At least five insulation thickness measurements in different places shall be made for each 100 m2insulation area. A pin or ruler graduated in millimetres shall normally be used for these measurements. In case of dispute the installed insulation thickness shall be measured in accordance with EN 823:2013, Annex A, pin and plate method. 5.2 Calculation of declared installed thermal resistance, RD The declared installed thermal resistance, RDfor the mean insulation thic